Lateral shearing interferometry, dynamic wavefront sensing, and high-speed videokeratoscopy for noninvasive assessment of tear film surface characteristics: a comparative study

被引:27
|
作者
Szczesna, Dorota H. [1 ,2 ]
Alonso-Caneiro, David [2 ]
Iskander, D. Robert [2 ]
Read, Scott A. [2 ]
Collins, Michael J. [2 ]
机构
[1] Wroclaw Univ Technol, Inst Phys, PL-50370 Wroclaw, Poland
[2] Queensland Univ Technol, Sch Optometry, Kelvin Grove Brisbane, Qld 4059, Australia
关键词
tear film kinetics; videokeratoscopy; wavefront sensing; interferometry; SHACK-HARTMANN ABERROMETER; DRY EYE; BUILDUP TIME; BREAK-UP; ABERRATIONS; LAYER; MICROFLUCTUATIONS; TOPOGRAPHY; STABILITY; QUALITY;
D O I
10.1117/1.3431103
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There are several noninvasive techniques for assessing the kinetics of tear film, but no comparative studies have been conducted to evaluate their efficacies. Our aim is to test and compare techniques based on high-speed videokeratoscopy (HSV), dynamic wavefront sensing (DWS), and lateral shearing interferometry (LSI). Algorithms are developed to estimate the tear film build-up time T(BLD), and the average tear film surface quality in the stable phase of the interblink interval TFSQ(Av). Moderate but significant correlations are found between T(BLD) measured with LSI and DWS based on vertical coma (Pearson's r(2) = 0.34, p<0.01) and higher order rms (r(2) = 0.31, p<0.01), as well as between TFSQ(Av) measured with LSI and HSV (r(2) = 0.35, p<0.01), and between LSI and DWS based on the rms fit error (r(2) = 0.40, p<0.01). No significant correlation is found between HSV and DWS. All three techniques estimate tear film build-up time to be below 2.5 sec, and they achieve a remarkably close median value of 0.7 sec. HSV appears to be the most precise method for measuring tear film surface quality. LSI appears to be the most sensitive method for analyzing tear film build-up. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3431103]
引用
收藏
页数:9
相关论文
共 4 条
  • [1] Unified approach to tear film surface analysis with high-speed videokeratoscopy
    Llorens-Quintana, Clara
    Szczesna-Iskander, Dorota H.
    Iskander, D. Robert
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2019, 36 (04) : B15 - B22
  • [2] Tear Film Surface Quality With Soft Contact Lenses Using Dynamic-Area High-Speed Videokeratoscopy
    Alonso-Caneiro, David
    Iskander, Robert
    Collins, Michael J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (05): : 227 - 231
  • [3] Assessment of Tear Film Surface Quality Using Dynamic-Area High-Speed Videokeratoscopy
    Alonso-Caneiro, David
    Iskander, D. Robert
    Collins, Michael J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (05) : 1473 - 1481
  • [4] Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy
    Llorens-Quintana, Clara
    Mousavi, Maryam
    Szczesna-Iskander, Dorota
    Iskander, D. Robert
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (01) : 18 - 22