The role of single photon emission computed tomography in bone imaging

被引:48
作者
Sarikaya, I
Sarikaya, A
Holder, LE
机构
[1] Univ Maryland, Dept Radiol, Med Syst, Div Nucl Med, Baltimore, MD 21201 USA
[2] Trakya Univ, Fac Med, Dept Nucl Med, Edirne, Turkey
关键词
D O I
10.1053/snuc.2001.18736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single photon emission computed tomography (SPECT) of the bone is the second most frequently performed SPECT examination in routine nuclear medicine practice, with cardiac SPECT being the most frequent. Compared with planar scintigraphy, SPECT increases image contrast and improves lesion detection and localization. Studies have documented the unique diagnostic information provided by SPECT, particularly for avascular necrosis of the femoral head, in patients with back pain, for the differential diagnosis between malignant and benign spinal lesions, in the detection of metastatic cancer in the spine, for the diagnosis of temporomandibular joint internal derangement, and for the evaluation of acute and chronic knee pain. Although less rigorously documented, SPECT is being increasingly used in all types of situations that demand more precise anatomic localization of abnormal tracer uptake. The effectiveness of bone SPECT increases with the selection of the proper collimator, which allows one to acquire adequate counts and minimize the patient-to-detector distance, Low-energy, ultrahigh-resolution or high-resolution collimation is preferred over all-purpose collimators. Multihead gamma cameras can increase the counts obtained or shorten acquisition time, making SPECT acquisitions more practical in busy departments and also increasing image quality compared with single-head cameras. Iterative reconstruction, with the use of ordered subsets estimation maximization, provides better quality images than classical filtered back projection algorithms. Three-dimensional image analysis often aids lesion localization. Copyright a 2001 by W.B. Saunders Company.
引用
收藏
页码:3 / 16
页数:14
相关论文
共 171 条
  • [91] Technical considerations for optimal orthopedic imaging
    Kelty, NL
    Cao, ZJ
    Holder, LE
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (04) : 328 - 333
  • [92] EVALUATION OF THE SKULL BASE BY SPECT - A COMPARISON WITH PLANAR SCINTIGRAPHY AND COMPUTED-TOMOGRAPHY
    KEOGAN, MT
    ANTOUN, N
    WRAIGHT, EP
    [J]. CLINICAL NUCLEAR MEDICINE, 1994, 19 (12) : 1055 - 1059
  • [93] KIM KY, 1993, INT ORTHOP, V17, P132
  • [94] Use of three-phase bone scans and SPET in the follow-up of patients with allogenic vascularized femur transplants
    Kirschner, MH
    Manthey, N
    Tatsch, K
    Nerlich, A
    Hahn, K
    Hofmann, GO
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (06) : 517 - 524
  • [95] Kosuda S, 1996, J NUCL MED, V37, P975
  • [96] KOURIS K, 1988, Journal of Nuclear Medicine, V29, P868
  • [97] FLOW STUDY AND SPECT IMAGING FOR THE DIAGNOSIS OF GIANT-CELL TUMOR OF BONE
    KRASNOW, AZ
    ISITMAN, AT
    COLLIER, BD
    BATES, FT
    HELLMAN, RS
    [J]. CLINICAL NUCLEAR MEDICINE, 1988, 13 (02) : 89 - 92
  • [98] THE VALUE OF OBLIQUE ANGLE REORIENTATION IN SPECT BONE-SCINTIGRAPHY OF THE HIPS
    KRASNOW, AZ
    COLLIER, BD
    PECK, DC
    HELLMAN, RS
    DELLIS, CJ
    KIR, KM
    ISITMAN, AT
    [J]. CLINICAL NUCLEAR MEDICINE, 1990, 15 (05) : 287 - 292
  • [99] KRASNOW AZ, 1987, J NUCL MED, V28, P1268
  • [100] KRASNOW AZ, 1992, ANN NUCL MED, P21