Real-World Gestational Diabetes Screening: Problems with the Oral Glucose Tolerance Test in Rural and Remote Australia

被引:19
作者
Jamieson, Emma L. [1 ]
Spry, Erica P. [2 ,3 ]
Kirke, Andrew B. [1 ]
Atkinson, David N. [3 ]
Marley, Julia V. [2 ,3 ]
机构
[1] Univ Western Australia, Rural Clin Sch Western Australia, Bunbury 6233, Australia
[2] Kimberley Aboriginal Med Serv, Broome 6725, Australia
[3] Univ Western Australia, Rural Clin Sch Western Australia, Broome 6725, Australia
关键词
gestational diabetes; GDM; oral glucose tolerance test; OGTT; glycolysis; PLASMA-GLUCOSE; SODIUM-FLUORIDE; PREGNANCY; MELLITUS; HYPERGLYCEMIA; DIAGNOSIS; IMPACT; RECOMMENDATIONS; ASSOCIATION; PREVALENCE;
D O I
10.3390/ijerph16224488
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Gestational diabetes mellitus (GDM) is the most common antenatal complication in Australia. All pregnant women are recommended for screening by 75 g oral glucose tolerance test (OGTT). As part of a study to improve screening, 694 women from 27 regional, rural and remote clinics were recruited from 2015-2018 into the Optimisation of Rural Clinical and Haematological Indicators for Diabetes in pregnancy (ORCHID) study. Most routine OGTT samples were analysed more than four hours post fasting collection (median 5.0 h, range 2.3 to 124 h), potentially reducing glucose levels due to glycolysis. In 2019, to assess pre-analytical plasma glucose (PG) instability over time, we evaluated alternative sample handling protocols in a sample of participants. Four extra samples were collected alongside routine room temperature (RT) fluoride-oxalate samples (FLOXRT): study FLOXRT; ice slurry (FLOXICE); RT fluoride-citrate-EDTA (FC Mix), and RT lithium-heparin plasma separation tubes (PST). Time course glucose measurements were then used to estimate glycolysis from ORCHID participants who completed routine OGTT after 24 weeks gestation (n = 501). Adjusting for glycolysis using FLOXICE measurements estimated 62% under-diagnosis of GDM (FLOXRT 10.8% v FLOXICE 28.5% (95% CI, 20.8-29.5%), p < 0.001). FC Mix tubes provided excellent glucose stability but gave slightly higher results (Fasting PG: +0.20 +/- 0.05 mmol/L). While providing a realistic alternative to the impractical FLOXICE protocol, direct substitution of FC Mix tubes in clinical practice may require revision of GDM diagnostic thresholds.
引用
收藏
页数:18
相关论文
共 37 条
[1]   Gestational diabetes mellitus prevalence: Effect of the laboratory analytical variation [J].
Agarwal, M. M. ;
Dhatt, G. S. ;
Othman, Y. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 109 (03) :493-499
[2]   Gestational diabetes mellitus: Screening with fasting plasma glucose [J].
Agarwal, Mukesh M. .
WORLD JOURNAL OF DIABETES, 2016, 7 (14) :279-289
[3]  
[Anonymous], 1985, DIAB MELL REP WHO ST
[4]  
[Anonymous], 2011, Diabetes Care, DOI [DOI 10.2337/DC11-9998, 10.2337/dc11-9998]
[5]  
Badrick T., 2015, JOINT INITIATIVE AUS
[6]   Pre-analytical effects of different lithium heparin plasma separation tubes in the routine clinical chemistry laboratory [J].
Brandhorst, Gunnar ;
Engelmayer, Jutta ;
Goetze, Sandra ;
Oellerich, Michael ;
von Ahsen, Nicolas .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (09) :1473-1477
[7]   Collection tubes containing citrate stabiliser over-estimate plasma glucose, when compared to other samples undergoing immediate plasma separation [J].
Carey, Rebekah ;
Lunt, Helen ;
Heenan, Helen F. ;
Frampton, Christopher M. A. ;
Florkowski, Christopher M. .
CLINICAL BIOCHEMISTRY, 2016, 49 (18) :1406-1411
[8]  
Carta M, 2015, BIOCHIM CLIN, V39, P135
[9]  
CHAN AYW, 1989, CLIN CHEM, V35, P315
[10]   Plasma glucose measurement in diabetes: impact and implications of variations in sample collection procedures with a focus on the first hour after sample collection [J].
Chan, Huan ;
Lunt, Helen ;
Thompson, Harmony ;
Heenan, Helen F. ;
Frampton, Christopher M. A. ;
Florkowski, Christopher M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (07) :1061-1068