An automatic approach for calibrating dielectric bone properties by combining finite-element and optimization software tools

被引:4
作者
Su, Yukun [1 ]
Kluess, Daniel [1 ]
Mittelmeier, Wolfram [1 ]
van Rienen, Ursula [2 ]
Bader, Rainer [1 ]
机构
[1] Univ Med Rostock, Dept Orthopaed, Rostock, Germany
[2] Univ Rostock, Inst Gen Elect Engn, D-18055 Rostock, Germany
关键词
Bone; dielectric properties; conductivity; permittivity; electrical stimulation; optimization; ELECTROMAGNETIC-FIELDS; ORTHOPEDIC IMPLANTS; BIOLOGICAL TISSUES; EXPOSURE;
D O I
10.1080/10255842.2015.1131980
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The dielectric properties of human bone are one of the most essential inputs required by electromagnetic stimulation for improved bone regeneration. Measuring the electric properties of bone is a difficult task because of the complexity of the bone structure. Therefore, an automatic approach is presented to calibrate the electric properties of bone. The numerical method consists of three steps: generating input from experimental data, performing the numerical simulation, and calibrating the bone dielectric properties. As an example, the dielectric properties at 20Hz of a rabbit distal femur were calibrated. The calibration process was considered as an optimization process with the aim of finding the optimum dielectric bone properties that match most of the numerically calculated simulation and experimentally measured data sets. The optimization was carried out automatically by the optimization software tool iSIGHT in combination with the finite-element solver COMSOL Multiphysics. As a result, the optimum conductivity and relative permittivity of the rabbit distal femur at 20Hz were found to be 0.09615 S/m and 19522 for cortical bone and 0.14913S/m and 1561507 for cancellous bone, respectively. The proposed method is a potential tool for the identification of realistic dielectric properties of the entire bone volume. The presented approach combining iSIGHT with COMSOL is applicable to, amongst others, designing implantable electro-stimulative devices or the optimization of electrical stimulation parameters for improved bone regeneration.
引用
收藏
页码:1306 / 1313
页数:8
相关论文
共 31 条
  • [1] Treatment of nonunions with electric and electromagnetic fields
    Aaron, RK
    Ciombor, DM
    Simon, BJ
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (419) : 21 - 29
  • [2] MODIFICATION OF FRACTURE REPAIR WITH SELECTED PULSING ELECTROMAGNETIC-FIELDS
    BASSETT, CAL
    VALDES, MG
    HERNANDEZ, E
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (06) : 888 - 895
  • [3] TREATMENT OF UNUNITED TIBIAL DIAPHYSEAL FRACTURES WITH PULSING ELECTROMAGNETIC-FIELDS
    BASSETT, CAL
    MITCHELL, SN
    GASTON, SR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (04) : 511 - 523
  • [5] Arthroscopically assisted therapy of avascular necrosis of the femoral head
    Ellenrieder, M.
    Tischer, T.
    Kreuz, P. C.
    Froehlich, S.
    Fritsche, A.
    Mittelmeier, W.
    [J]. OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2013, 25 (01): : 85 - 94
  • [6] The dielectric properties of biological tissues .1. Literature survey
    Gabriel, C
    Gabriel, S
    Corthout, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) : 2231 - 2249
  • [7] The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz
    Gabriel, S
    Lau, RW
    Gabriel, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) : 2251 - 2269
  • [8] The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues
    Gabriel, S
    Lau, RW
    Gabriel, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) : 2271 - 2293
  • [9] Electromagnetic field stimulation for treating delayed union or non-union of long bone fractures in adults
    Griffin, X. L.
    Costa, M. L.
    Parsons, N.
    Smith, N.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2011, (04):
  • [10] Hambli Ridha, 2014, Front Bioeng Biotechnol, V2, P6, DOI 10.3389/fbioe.2014.00006