Protocol for a prospective, controlled, cross-sectional, diagnostic accuracy study to evaluate the specificity and sensitivity of ambulatory monitoring systems in the prompt detection of hypoxia and during movement

被引:6
作者
Areia, Carlos [1 ]
Vollam, Sarah [1 ]
Piper, Philippa [2 ]
King, Elizabeth [2 ]
Ede, Jody [1 ]
Young, Louise [1 ]
Santos, Mauro [3 ]
Pimentel, Marco A. F. [3 ]
Roman, Cristian [3 ]
Harford, Mirae [1 ]
Shah, Akshay [4 ]
Gustafson, Owen [2 ]
Rowland, Matthew [1 ]
Tarassenko, Lionel [3 ]
Watkinson, Peter J. [1 ]
机构
[1] Univ Oxford, Crit Care Res Grp, Nuffield Dept Clin Neurosci, Oxford, England
[2] Oxford Univ Hosp NHS Fdn Trust, Adult Intens Care Unit, Oxford, England
[3] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Oxford, England
[4] Univ Oxford, Radcliffe Dept Med, Oxford, England
基金
英国工程与自然科学研究理事会;
关键词
hypoxia; ambulatory monitoring; vital signs; wearable devices;
D O I
10.1136/bmjopen-2019-034404
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Automated continuous ambulatory monitoring may provide an alternative to intermittent manual vital signs monitoring. This has the potential to improve frequency of measurements, timely escalation of care and patient safety. However, a major barrier to the implementation of these wearable devices in the ward environment is their uncertain reliability, efficiency and data fidelity. The purpose of this study is to test performance of selected devices in a simulated clinical setting including during movement and low levels of peripheral oxygen saturation. Methods and analysis This is a single centre, prospective, controlled, cross-sectional, diagnostic accuracy study to determine the specificity and sensitivity of currently available ambulatory vital signs monitoring equipment in the detection of hypoxia and the effect of movement on data acquisition. We will recruit up to 45 healthy volunteers who will attend a single study visit; starting with a movement phase and followed by the hypoxia exposure phase where we will gradually decrease saturation levels down to 80%. We will simultaneously test one chest patch, one wrist worn only and three wrist worn with finger probe devices against 'clinical standard 'and 'gold standard' references. We will measure peripheral oxygen saturations, pulse rate, heart rate and respiratory rate continuously and arterial blood gases intermittently throughout the study. Ethics and dissemination This study has received ethical approval by the East of Scotland Research Ethics Service REC 2 (19/ES/0008). The results will be broadly distributed through conference presentations and peer-reviewed publications.
引用
收藏
页数:8
相关论文
共 12 条
[1]  
Appelboom G, 2014, ARCH PUBLIC HEALTH, V72, DOI 10.1186/2049-3258-72-28
[2]   Vital signs monitoring and nurse-patient interaction: A qualitative observational study of hospital practice [J].
Cardona-Morrell, M. ;
Prgomet, M. ;
Lake, R. ;
Nicholson, M. ;
Harrison, R. ;
Long, J. ;
Westbrook, J. ;
Braithwaite, J. ;
Hillman, K. .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 2016, 56 :9-16
[3]   SPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials [J].
Chan, An-Wen ;
Tetzlaff, Jennifer M. ;
Altman, Douglas G. ;
Laupacis, Andreas ;
Gotzsche, Peter C. ;
Krleza-Jeric, Karmela ;
Hrobjartsson, Asbjorn ;
Mann, Howard ;
Dickersin, Kay ;
Berlin, Jesse A. ;
Dore, Caroline J. ;
Parulekar, Wendy R. ;
Summerskill, William S. M. ;
Groves, Trish ;
Schulz, Kenneth F. ;
Sox, Harold C. ;
Rockhold, Frank W. ;
Rennie, Drummond ;
Moher, David .
ANNALS OF INTERNAL MEDICINE, 2013, 158 (03) :200-+
[4]   Causes and Mechanisms of Intrauterine Hypoxia and Its Impact on the Fetal Cardiovascular System: A Review [J].
Hutter, Damian ;
Kingdom, John ;
Jaeggi, Edgar .
INTERNATIONAL JOURNAL OF PEDIATRICS, 2010, 2010
[5]   Detecting critical illness outside the ICU: the role of track and trigger systems [J].
Jansen, Jan O. ;
Cuthbertson, Brian H. .
CURRENT OPINION IN CRITICAL CARE, 2010, 16 (03) :184-190
[6]   Accuracy of Pulse Oximeters in Detecting Hypoxemia in Patients with Chronic Thromboembolic Pulmonary Hypertension [J].
Kohyama, Tomoki ;
Moriyama, Kiyoshi ;
Kanai, Riichiro ;
Kotani, Mariko ;
Uzawa, Kohji ;
Satoh, Toru ;
Yorozu, Tomoko .
PLOS ONE, 2015, 10 (05)
[7]   Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and Motion [J].
Louie, Aaron ;
Feiner, John R. ;
Bickler, Philip E. ;
Rhodes, Laura ;
Bernstein, Michael ;
Lucero, Jennifer .
ANESTHESIOLOGY, 2018, 128 (03) :520-530
[8]  
McQuillan P, 1998, BMJ-BRIT MED J, V316, P1853
[9]   Vital signs monitoring on general wards: clinical staff perceptions of current practices and the planned introduction of continuous monitoring technology [J].
Prgomet, Mirela ;
Cardona-Morrell, Magnolia ;
Nicholson, Margaret ;
Lake, Rebecca ;
Long, Janet ;
Westbrook, Johanna ;
Braithwaite, Jeffrey ;
Hillman, Ken .
INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2016, 28 (04) :515-521
[10]  
Rowland MJ, 2017, J CEREB BLOOD FLOW M, V0271678X, P1772662