Clothes dryers play an important role in modern daily life which consumes a lot of residential electricity. The closed-loop heat pump clothes dryer is a typical energy-saving application in heat pump drying. To predict and analyze both electricity consumption and drying time, a quasi-steady-state model of the closed-loop heat pump dryer was developed, which consists of a dynamic fabric drying model and a steady-state heat pump system model. Simulation results reached a good agreement with test data of a household heat pump clothes dryer. The error of drying time is within 3 min and that of electricity consumption is -2.3%. Based on the model, the effects of compressor size, area ratio of the evaporator to total, circulating air flow rate, condensing temperature upper bound, and refrigerant charge on specific moisture extraction rate (SMER) and drying time were analyzed. Moreover, comprehensive optimization was performed using response surface method with the Box-Behnken design. The SMER of the redesigned clothes dryer is 2.92 kg/kWh, showing an increase of 5.8%, and the drying time is 129 min, showing a decrease of 14.6% compared with the original design.
引用
收藏
页数:13
相关论文
共 39 条
[1]  
[Anonymous], 2008, GBT231182008 STAND A
[2]   ANALYSIS OF RANKINE-CYCLE HEAT-PUMP DRIERS [J].
BAINES, PG ;
CARRINGTON, CG .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1988, 12 (03) :495-510
[3]   Improving the energy efficiency of conventional tumbler clothes drying systems [J].
Bansal, PK ;
Braun, JE ;
Groll, EA .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (15) :1315-1332
[4]   Advances in household appliances - A review [J].
Bansal, Pradeep ;
Vineyard, Edward ;
Abdelaziz, Omar .
APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) :3748-3760
[5]   Performance analysis of an electric clothes dryer [J].
Bassily, AM ;
Colver, GM .
DRYING TECHNOLOGY, 2003, 21 (03) :499-524
[6]   Performance Study of a Closed-Type Heat Pump Tumble Dryer Using a Simulation Model and an Experimental Set-Up [J].
Bengtsson, Peder ;
Berghel, Jonas ;
Renstrom, Roger .
DRYING TECHNOLOGY, 2014, 32 (08) :891-901
[7]   Energy efficiency analysis of air cycle heat pump dryers [J].
Braun, JE ;
Bansal, PK ;
Groll, EA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (07) :954-965
[8]   A novel packaged outdoor air dehumidifier with exhaust air heat pump Experiment and simulation [J].
Cao, Xiang ;
Yang, Chen ;
Sun, Zhao ;
Lu, Yue-Ming ;
Chang, Meng-Meng ;
Shao, Liang-Liang ;
Zhang, Chun-Lu .
APPLIED THERMAL ENGINEERING, 2020, 181
[9]   Experimental investigation on a fresh air dehumidification system using heat pump with desiccant coated heat exchanger [J].
Chai, Shaowei ;
Sun, Xiangyu ;
Zhao, Yao ;
Dai, Yanjun .
ENERGY, 2019, 171 :306-314
[10]  
Chailoet A., 2010, 2 INT C MECH SYST CO