Additional diagnostic value of multiplane echocardiography over biplane imaging in assessment of mitral prosthetic valves

被引:7
作者
Faletra, F [1 ]
DeChiara, F [1 ]
Corno, R [1 ]
Passini, L [1 ]
机构
[1] OSPED NIGUARDA CA GRANDA,CENT CARDIOL SERV,A DE GASPERIS CARDIOL DEPT,MILAN,ITALY
关键词
transoesophageal echocardiography; biplane imaging; multiplane imaging; mitral prostheses;
D O I
10.1136/hrt.75.6.609
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To evaluate how often multiplane transoesophageal echocardiography yields new or complementary data in mitral prostheses in comparison with the exclusive use of biplane imaging. Patients-73 consecutive patients with mitral prostheses who underwent multiplane transoesophageal echocardiograpy between January 1993 and December 1994. Methods-Biplane images (transverse and longitudinal planes) and multiplane images (transverse, longitudinal, and intermediate planes) were recorded on two separate videotapes. The data provided by multiplane transoesophageal echocardiography were evaluated as (a) new data (abnormalities missed by biplane imaging); (b) complementary data (better delineating lesions already visualised by biplane imaging); or (c) redundant data (data already provided by biplane imaging). Results-Multiplane transoesophageal echocardiography revealed new abnormalities in seven patients (9.5%) (thrombi in three and paraprosthetic leaks in the remaining four) and complementary data in nine (12.3%). In patients with paraprosthetic regurgitation, the possibility of continuously visualising the sewing ring by means of sequential angulations allowed the circumferential extension of the leak to be measured. In seven patients with paravalvar regurgitation who underwent surgery, the extension of the leak as measured by the multiplane approach closely corresponded with the surgical data. Conclusions-In comparison with the exclusive use of biplane imaging, the multiplane approach added new or complementary data in a significant proportion of patients with mitral prostheses. The ability to obtain the sequential adjacent planes allowed a more reliable appraisal of the extension of the leak and other abnormalities.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 8 条
[1]  
Flachskampf F A, 1995, J Am Soc Echocardiogr, V8, P70, DOI 10.1016/S0894-7317(05)80360-8
[2]   INITIAL EXPERIENCE WITH A MULTIPLANE TRANSESOPHAGEAL ECHO-TRANSDUCER - ASSESSMENT OF DIAGNOSTIC POTENTIAL [J].
FLACHSKAMPF, FA ;
HOFFMANN, R ;
VERLANDE, M ;
SCHNEIDER, W ;
AMELING, W ;
HANRATH, P .
EUROPEAN HEART JOURNAL, 1992, 13 (09) :1201-1206
[3]  
GROUNDSTROEM K, 1993, BRIT HEART J, V70, P259
[4]  
KHANDERIA BK, 1991, CIRCULATION, V68, P689
[5]   MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY - IMAGING PLANES, ECHOCARDIOGRAPHIC ANATOMY, AND CLINICAL-EXPERIENCE WITH A PROTOTYPE PHASED-ARRAY OMNIPLANE PROBE [J].
PANDIAN, NG ;
HSU, TL ;
SCHWARTZ, SL ;
WEINTRAUB, A ;
CAO, QL ;
SCHNEIDER, AT ;
GORDON, G ;
ENGLAND, M ;
SIMONETTI, J .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (06) :649-666
[6]  
Roelandt J R, 1992, J Am Soc Echocardiogr, V5, P361
[7]   MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY - IMAGE ORIENTATION, EXAMINATION TECHNIQUE, ANATOMIC CORRELATIONS, AND CLINICAL-APPLICATIONS [J].
SEWARD, JB ;
KHANDHERIA, BK ;
FREEMAN, WK ;
OH, JK ;
ENRIQUEZSARANO, M ;
MILLER, FA ;
EDWARDS, WD ;
TAJIK, AJ .
MAYO CLINIC PROCEEDINGS, 1993, 68 (06) :523-551
[8]   CLINICAL USEFULNESS OF MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY - COMPARISON TO BIPLANAR IMAGING [J].
TARDIF, JC ;
SCHWARTZ, SL ;
VANNAN, MA ;
CAO, QL ;
PANDIAN, NG .
AMERICAN HEART JOURNAL, 1994, 128 (01) :156-166