Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry

被引:51
作者
Casson, R [1 ]
James, B [1 ]
Rubinstein, A [1 ]
Ali, H [1 ]
机构
[1] Stoke Mandeville Eye Unit, Aylesbury HP21 8AL, Bucks, England
关键词
D O I
10.1136/bjo.85.3.360
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim-To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. Methods-In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to determine the sensitivity and specificity of the FDT perimetry compared with the full threshold H24-2 as the gold standard. Results-Missed points on the FDT perimetry correlated with both the mean deviation and the corrected pattern standard deviation on the Humphrey perimetry. A score assigned to abnormal points on the FDT perimetry and the Humphrey total deviation plot showed a significant correlation for both the location and the depth of the defect. In comparing the Humphrey hemifield test with the FDT perimetry results, if at least one missed point on the frequency doubling test was considered as abnormal then the overall sensitivity of the test was 78.1% and the specificity was 89.1%. Conclusion-FDT perimetry in the screening mode performed in a clinical setting was highly specific, exhibited reasonable sensitivity, and accurately determined the location and depth of scotomas when compared with the full threshold Humphrey 24-2.
引用
收藏
页码:360 / 362
页数:3
相关论文
共 16 条
[1]  
Brusini P, 1998, ACTA OPHTHALMOL SCAN, V76, P23
[2]   Comparison of frequency doubling perimetry with Humphrey visual field analysis in a glaucoma practice [J].
Burnstein, Y ;
Ellish, NJ ;
Magbalon, M ;
Higginbotham, EJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :328-333
[3]   Frequency doubling technology perimetry for detection of glaucomatous visual field loss [J].
Cello, KE ;
Nelson-Quigg, JM ;
Johnson, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :314-322
[4]  
Chauhan BC, 1999, INVEST OPHTH VIS SCI, V40, P648
[5]  
Johnson CA, 1997, INVEST OPHTH VIS SCI, V38, P413
[6]   Frequency doubling technology perimetry using a 24-2 stimulus presentation pattern [J].
Johnson, CA ;
Cioffi, GA ;
Van Buskirk, EM .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) :571-581
[7]   FREQUENCY DOUBLING IN VISUAL RESPONSES [J].
KELLY, DH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1966, 56 (11) :1628-&
[8]   Testing for glaucoma with the frequency-doubling illusion in the whole, macular and eccentric visual fields [J].
Maddess, T ;
Severt, WL .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1999, 27 (3-4) :194-196
[9]  
MADDESS T, 1992, CLIN VISION SCI, V7, P371
[10]  
MADDESS T, 1995, INVEST OPHTH VIS SCI, V36, pS335