Electrochemical and Electrochemiluminescence Determination of Cancer Cells Based on Aptamers and Magnetic Beads

被引:75
作者
Ding, Caifeng [1 ]
Ge, Ying [1 ]
Zhang, Shusheng [1 ]
机构
[1] Qingdao Univ Sci & Technol, State Key Lab Base Ecochem Engn, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
关键词
aptamers; cancer; electrochemistry; luminescence; nanoparticles; DISSEMINATED TUMOR-CELLS; SURFACE CARBOHYDRATE; DNA HYBRIDIZATION; LEUKEMIA; BLOOD; DIFFERENTIATION; AMPLIFICATION; NANOPARTICLES; ARCHITECTURE; SELECTION;
D O I
10.1002/chem.201001173
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical and electrochemiluminescence (ECL) detection of cell lines of Burkitt's lymphoma (Ramos) by using magnetic beads as the separation tool and high-affinity DNA aptamers for signal recognition is reported. Au nanoparticles (NPs) bifunctionalized with aptamers and CdS NPs were used for electrochemical signal amplification. The anodic stripping voltammetry technology employed for the analysis of cadmium ions dissolved from CdS NPs on the aggregates provided a means to quantify the amount of the target cells. This electrochemical method could respond clown to 67 cancer cells per mL with a linear calibration range from 1.0 x 10(2) to 1.0 x 10(5) cells mL(-1), which shows very high sensitivity. In addition, the assay was able to differentiate between target and control cells based on the aptamer used in the assay, indicating the wide applicability of the assay for diseased cell detection. ECL detection was also performed by functionalizing the signal DNA, which was complementary to the aptamer of the Ramos cells, with tris(2,2-bipyridyl) ruthenium. The ECL intensity of the signal DNA, replaced by the target cells from the ECL probes, directly reflected the quantity of the amount of the cells. With the use of the developed ECL probe, a limit of detection as low as 89 Ramos cells per mL could be achieved. The proposed methods based on electrochemical and ECL should have wide applications in the diagnosis of cancers due to their high sensitivity, simplicity, and low cost.
引用
收藏
页码:10707 / 10714
页数:8
相关论文
共 42 条
[1]  
Belov L, 2001, CANCER RES, V61, P4483
[2]  
Brody E N, 2000, J Biotechnol, V74, P5, DOI 10.1016/S1389-0352(99)00004-5
[3]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[4]   Mapping Receptor Density on Live Cells by Using Fluorescence Correlation Spectroscopy [J].
Chen, Yan ;
Munteanu, Alina C. ;
Huang, Yu-Fen ;
Phillips, Joseph ;
Zhu, Zhi ;
Mavros, Michael ;
Tan, Weihong .
CHEMISTRY-A EUROPEAN JOURNAL, 2009, 15 (21) :5327-5336
[5]   Effective cell capture with tetrapeptide-functionalized carbon nanotubes and dual signal amplification for cytosensing and evaluation of cell surface carbohydrate [J].
Cheng, Wei ;
Ding, Lin ;
Lei, Jianping ;
Ding, Shijia ;
Ju, Huangxian .
ANALYTICAL CHEMISTRY, 2008, 80 (10) :3867-3872
[6]  
COLIN DM, 2008, ANAL CHEM, V80, P1067
[7]   A tenascin-C aptamer identified by tumor cell SELEX: Systematic evolution of ligands by exponential enrichment [J].
Daniels, DA ;
Chen, H ;
Hicke, BJ ;
Swiderek, KM ;
Gold, L .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (26) :15416-15421
[8]   Carbohydrate monolayer strategy for electrochemical assay of cell surface carbohydrate [J].
Ding, Lin ;
Cheng, Wei ;
Wang, Xiaojian ;
Ding, Shijia ;
Ju, Huangxian .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (23) :7224-+
[9]   Electrochemical immunoassay of membrane P-glycoprotein by immobilization of cells on gold nanoparticles modified on a methoxysilyl-terminated butyrylchitosan matrix [J].
Du, D ;
Ju, HX ;
Zhang, XJ ;
Chen, J ;
Cai, J ;
Chen, HY .
BIOCHEMISTRY, 2005, 44 (34) :11539-11545
[10]   Clinical significance of cytogenetic abnormalities in adult acute lymphoblastic leukemia [J].
Faderl, S ;
Kantarjian, HM ;
Talpaz, M ;
Estrov, Z .
BLOOD, 1998, 91 (11) :3995-4019