The fieldwork and control engineering studies on thermal comfort of occupants in a conventional office building in the tropics

被引:2
|
作者
Yau, Y. H. [1 ]
Chang, C. P. [1 ]
机构
[1] Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
来源
BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY | 2016年 / 37卷 / 03期
关键词
Fuzzy logic; thermostat; thermal comfort; actual mean vote; air conditioning; ENERGY; DESIGN;
D O I
10.1177/0143624415611580
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the fieldwork and the control system studies to examine and improve the thermal comfort of the occupants in a typical office building in Malaysia. The proposed control system works as the basis of adjusting the thermostat setting at a certain period of time with the degree of using the fuzzy logic. The thermostat of the central AC system has its set point fixed between 21? and 22?, slightly below the range of 23-26? as recommended by Malaysian Standard MS1525. In order to maintain the room comfort, the occupants choose to switch OFF the central AC system for a certain period of time before it is switched back ON. It has been repeated at least once per working days. Therefore, the proposed control system is designed to overcome this practice. Pre- and post-comfort surveys have been conducted where the thermal comfort level of the occupants throughout this study is investigated. The air temperature (T-a), globe temperature (T-g), air velocity (V) and relative humidity (RH) in the occupied area were data-logged for continuous five working days. These data are used to compute the operative temperature (T-op) before new thermostat set points are generated, which indicates possible adjustment from the recommended set-point (24?). The proposed thermostat setting has an error tolerance of 2.9% or less. As a result, the simulation results show an adjustment of the thermostat setting from 24? to 25.5?, which successfully maintained the room temperature of the main office between 23.3? and 25?. The relative humidity is maintained between 54.3% and 59.8%. Also, these outcomes have indirectly promoted an average increase of 22.6% in the thermal comfort satisfactory level of the occupants. Practical application: The new conclusions from the simplified thermostat control strategy, which can be customised according to the environment variables in the air-conditioned space (in this case the operative temperature and the relative humidity) or based on the preferences of the occupants, such as the level of thermal comfort that suits the current thermal environment in tropical climates, could be applied as an important guide for building services engineers and researchers. Their aims are to reduce energy usage in HVAC systems in the non-green office buildings in tropical climates while maintaining an adequate thermal comfort level, and thus, the performance and well-being of the office workers are improved.
引用
收藏
页码:355 / 373
页数:19
相关论文
共 50 条
  • [21] Evaluating the Building Performance of an Office Building in London to Improve Indoor Thermal Comfort
    Elsharkawy, Heba
    Zahiri, Sahar
    SMART AND HEALTHY WITHIN THE TWO-DEGREE LIMIT (PLEA 2018), VOL 3, 2018, : 978 - 979
  • [22] Gender differences and non-thermal factors in thermal comfort of office occupants in a hot-arid climate
    Erlandson, TM
    Cena, K
    de Dear, R
    Environmental Ergonomics: THE ERGONOMICS OF HUMAN COMFORT, HEALTH AND PERFORMANCE IN THE THERMAL ENVIRONMENT, 2005, 3 : 263 - 268
  • [23] Understanding Occupants' Thermal Sensitivity According to Solar Radiation in an Office Building with Glass Curtain Wall Structure
    Kim, Sung-Kyung
    Ryu, Ji-Hye
    Seo, Hyun-Cheol
    Hong, Won-Hwa
    BUILDINGS, 2022, 12 (01)
  • [24] Investigating thermal comfort and occupants position impacts on building sustainability using CFD and BIM
    Pazhoohesh, Mehdi
    Shahmir, Raja
    Zhang, Cheng
    LIVING AND LEARNING: RESEARCH FOR A BETTER BUILT ENVIRONMENT, 2015, : 257 - 266
  • [25] Coupling a neural network temperature predictor and a fuzzy logic controller to perform thermal comfort regulation in an office building
    Marvuglia, Antonino
    Messineo, Antonio
    Nicolosi, Giuseppina
    BUILDING AND ENVIRONMENT, 2014, 72 : 287 - 299
  • [26] Uncertainty analysis of thermal comfort in a prototypical naturally ventilated office building and its implications compared to deterministic simulation
    Chen, Jianli
    Augenbroe, Godfried
    Wang, Qinpeng
    Song, Xinyi
    ENERGY AND BUILDINGS, 2017, 146 : 283 - 294
  • [27] Transformation of an Office Building into a Nearly Zero Energy Building (nZEB): Implications for Thermal and Visual Comfort and Energy Performance
    Ballarini, Ilaria
    De Luca, Giovanna
    Paragamyan, Argun
    Pellegrino, Anna
    Corrado, Vincenzo
    ENERGIES, 2019, 12 (05)
  • [28] Building Integrated Shading and Building Applied Photovoltaic System Assessment in the Energy Performance and Thermal Comfort of Office Buildings
    Martinopoulos, Georgios
    Serasidou, Anna
    Antoniadou, Panagiota
    Papadopoulos, Agis M.
    SUSTAINABILITY, 2018, 10 (12)
  • [29] Evaluation of thermal comfort in a historic building refurbished to an office building with modernized HVAC systems
    Bakhtiari, H.
    Akander, J.
    Cehlin, M.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2020, 14 (02) : 218 - 237
  • [30] A Review on Adaptive Thermal Comfort of Office Building for Energy-Saving Building Design
    Lamsal, Prativa
    Bajracharya, Sushil Bahadur
    Rijal, Hom Bahadur
    ENERGIES, 2023, 16 (03)