Experimental investigation on shear performance of transverse angle shear connectors

被引:29
作者
Jiang, Haibo [1 ]
Fang, Haozhen [1 ]
Liu, Jie [1 ]
Fang, Zhuangcheng [1 ]
Zhang, Jianfeng [1 ]
机构
[1] Guangdong Univ Technol, Guangzhou Higher Educ Mega Ctr, Sch Civil & Transportat Engn, Guangzhou 510006, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel-concrete composite structures; Shear behavior; Angle shear connector; PUSH-OUT TESTS; MECHANICAL-BEHAVIOR; COMPOSITE GIRDERS; STEEL; PERFOBOND; RESISTANCE; STRENGTH; BRIDGES;
D O I
10.1016/j.istruc.2021.05.071
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To overcome the concrete casting obstruction of the bottom slabs in prestressed concrete box-girders with corrugated steel webs (CSWs), transverse angle shear connectors were adopted in some cases. The overall behavior of such steel-concrete structures highly depended on the shear behavior of the connectors. Seven large-scale push-out specimens, with different height and spacing of shear connectors, were tested to examine the shear performance of transverse angle shear connectors. The failure modes, load-slip relationships, ultimate shear strengths, initial stiffness and ductility of specimens were explored. Based on the experimental results, this study suggests that both of the connector height and spacing impacted the shear strength of transverse angle connectors. The initial stiffness of specimens improved with the increasing of both connector height and number. The ductile characteristic can also be observed in the load-slip relationship. Compared with traditional longitudinal PBL shear connector, the transverse angle shear connectors also showed apparent strength enhancement and acceptable ductile characteristic. The equation for angle shear connectors suggested in Eurocode 4 can be used for predicting the shear strength of transverse angle shear connectors with spacing ranged from 350 mm to 450 mm.
引用
收藏
页码:2050 / 2060
页数:11
相关论文
共 37 条
[1]   Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement [J].
Ahn, Jin-Hee ;
Lee, Chan-Goo ;
Won, Jeong-Hun ;
Kim, Sang-Hyo .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) :1295-1307
[2]  
AISC, 2016, SPEC STRUCT STEEL BU
[3]  
[Anonymous], 2011, Standard Test Method for Knoop and Vickers Hardness of Materials E384, P1, DOI DOI 10.1520/C0496_C0496M-11
[4]  
[Anonymous], 2004, EN 1994-1-1
[5]  
ASTM, 2015, C1231C1231M15 ASTM A
[6]  
ASTM, 2021, Standard Test Method for Static Modulus of elasticity and Poissons ratio of concrete in Compression
[7]   Study on Behaviour of Angle Shear Connector in steel-concrete Composite Structures [J].
Balasubramanian, Raguvaran ;
Rajaram, Baskar .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (03) :807-811
[8]   Behavior of steel-concrete partially composite beams with channel type shear connectors [J].
Baran, Eray ;
Topkaya, Cem .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 97 :69-78
[9]   Experimental evaluation of the structural response of Perfobond shear connectors [J].
Candido-Martins, J. P. S. ;
Costa-Neves, L. F. ;
Vellasco, P. C. G. da S. .
ENGINEERING STRUCTURES, 2010, 32 (08) :1976-1985
[10]   Interaction of plastic hinges in prestressed concrete bridges with corrugated steel webs [J].
Chen, X. C. ;
Zeng, Y. ;
Au, F. T. K. ;
Jiang, R. J. .
ENGINEERING STRUCTURES, 2017, 150 :359-372