Histomorphometry and micro-computed tomography of bone augmentation under a titanium membrane

被引:27
|
作者
Maréchal, M
Luyten, F
Nijs, J
Postnov, A
Schepers, E
van Steenberghe, D
机构
[1] Catholic Univ Louvain, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Periodontol, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, Fac Med, Dept Rheumatol, B-3000 Louvain, Belgium
[3] Catholic Univ Louvain, Fac Med, Dept Orthopaed Surg, B-3000 Louvain, Belgium
[4] Univ Antwerp, Dept Biomed Sci, Dept Phys, B-2020 Antwerp, Belgium
[5] Catholic Univ Louvain, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent, B-3000 Louvain, Belgium
关键词
bone augmentation; dental implants; histology; histomorphometry; membranes; micro-CT; periodontology; titanium;
D O I
10.1111/j.1600-0501.2005.01205.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Bone augmentation underneath an occlusive titanium membrane is evaluated in most cases by means of serial histological sections and histomorphometry. Micro-computed tomography (micro-CT) is a less invasive and dynamic technique to measure bone volume in animals of a size that fits into the gantry. The aim of the present study was to evaluate whether the latter approach could match histomorphometry to assess bone augmentation under a titanium membrane. Material and methods: Pre-formed titanium cups were placed on the skull of 16 rabbits. Bone formation underneath the cups was allowed to occur for 12 weeks. The amount of bone volume assessed by micro-CT was expressed as a numerical unit. One unit volume corresponds to 0.043 mm(3). The measurements reveal the volume of bone-like tissue under the membrane, with the same density as that of the original rabbit skull bone. Histological sections were cut along the same plane as the one used for the micro-CT images. The total bone surface was assessed by a digital image system in double-stained undecalcified histological sections and related to the maximum available surface of the titanium cups, which was on average 1366 mm(2). Results: The amount of total bone surface found under the titanium membrane varied between 40 and 163 mm(2). Measured by micro-CT, the bone detected ranged from 3.7 to 396 numerical units. A highly significant (P < 0.001) correlation was found between the total bone volume measured in conventional serial histological sections and by the micro-CT technique (r(2)=0.72). Conclusions: The total bone volume measured underneath a membrane using the micro-CT when compared with histological sections remained within a 16% error. This is because of the scattering effect of the metallic membrane and the impossibility to distinguish newly formed bone from the original skull bone on the micro-CT images.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [21] Micro-computed tomography assessment of bone structure in aging mice
    Junbo Shim
    Chihiro Iwaya
    Catherine G. Ambrose
    Akiko Suzuki
    Junichi Iwata
    Scientific Reports, 12
  • [22] VALIDATION OF A BONE MINERAL DENSITY CALIBRATION PROTOCOL FOR MICRO-COMPUTED TOMOGRAPHY
    Baruffaldi, Fabio
    Stoico, Rossella
    Tassani, Simone
    Mecozzi, Laura
    Falcioni, Stefano
    Fersini, Chiara
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [23] Is micro-computed tomography reliable to determine the microstructure of the maxillary alveolar bone?
    Gonzalez-Garcia, Raul
    Monje, Florencio
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 730 - 737
  • [24] Quantitative assessment of bone tissue mineralization with polychromatic micro-computed tomography
    Burghardt, Andrew J.
    Kazakia, Galateia J.
    Laib, Andres
    Majumdar, Sharmila
    CALCIFIED TISSUE INTERNATIONAL, 2008, 83 (02) : 129 - 138
  • [25] Quantification of bone formation and resorption rates by in vivo micro-computed tomography
    Gerhard, F. A.
    Lambers, F. M.
    Kuhn, G.
    Muller, R.
    BONE, 2009, 44 (02) : S245 - S245
  • [26] Quantitative Assessment of Bone Tissue Mineralization with Polychromatic Micro-Computed Tomography
    Andrew J. Burghardt
    Galateia J. Kazakia
    Andres Laib
    Sharmila Majumdar
    Calcified Tissue International, 2008, 83
  • [27] Impact of micro-computed tomography reconstruction protocols on bone microarachitecture analysis
    Leandro Nascimento, Eduarda Helena
    Gaeta-Araujo, Hugo
    Brasil, Danieli M.
    Madlum, Daniela Verardi
    Freitas, Deborah Q.
    Haiter-Neto, Frascisco
    Oliveira-Santos, Christiano
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (04): : 411 - 417
  • [28] The Effect of Micro-Computed Tomography Thresholding Methods on Bone Micromorphometric Analysis
    Buyuksungur, Arda
    Szabo, Bence Tamas
    Dobai, Adrienn
    Orhan, Kaan
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (11)
  • [29] Micro-computed tomography for evaluating alveolar bone resorption induced by hyperocclusion
    Tsutsumi, Takashi
    Kajiya, Hiroshi
    Tsuzuki, Takashi
    Goto, Kazuko T.
    Okabe, Koji
    Takahashi, Yutaka
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (03) : 298 - 302
  • [30] Fused micro-computed tomography (μCT) and histological images of bone specimens
    Mourad, C.
    Laperre, K.
    Halut, M.
    Galant, C.
    Van Cauter, M.
    Vande Berg, B. C.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (7-8) : 501 - 505