Histomorphometry and micro-computed tomography of bone augmentation under a titanium membrane

被引:27
|
作者
Maréchal, M
Luyten, F
Nijs, J
Postnov, A
Schepers, E
van Steenberghe, D
机构
[1] Catholic Univ Louvain, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Periodontol, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, Fac Med, Dept Rheumatol, B-3000 Louvain, Belgium
[3] Catholic Univ Louvain, Fac Med, Dept Orthopaed Surg, B-3000 Louvain, Belgium
[4] Univ Antwerp, Dept Biomed Sci, Dept Phys, B-2020 Antwerp, Belgium
[5] Catholic Univ Louvain, Fac Med, Sch Dent Oral Pathol & Maxillofacial Surg, Dept Prosthet Dent, B-3000 Louvain, Belgium
关键词
bone augmentation; dental implants; histology; histomorphometry; membranes; micro-CT; periodontology; titanium;
D O I
10.1111/j.1600-0501.2005.01205.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Bone augmentation underneath an occlusive titanium membrane is evaluated in most cases by means of serial histological sections and histomorphometry. Micro-computed tomography (micro-CT) is a less invasive and dynamic technique to measure bone volume in animals of a size that fits into the gantry. The aim of the present study was to evaluate whether the latter approach could match histomorphometry to assess bone augmentation under a titanium membrane. Material and methods: Pre-formed titanium cups were placed on the skull of 16 rabbits. Bone formation underneath the cups was allowed to occur for 12 weeks. The amount of bone volume assessed by micro-CT was expressed as a numerical unit. One unit volume corresponds to 0.043 mm(3). The measurements reveal the volume of bone-like tissue under the membrane, with the same density as that of the original rabbit skull bone. Histological sections were cut along the same plane as the one used for the micro-CT images. The total bone surface was assessed by a digital image system in double-stained undecalcified histological sections and related to the maximum available surface of the titanium cups, which was on average 1366 mm(2). Results: The amount of total bone surface found under the titanium membrane varied between 40 and 163 mm(2). Measured by micro-CT, the bone detected ranged from 3.7 to 396 numerical units. A highly significant (P < 0.001) correlation was found between the total bone volume measured in conventional serial histological sections and by the micro-CT technique (r(2)=0.72). Conclusions: The total bone volume measured underneath a membrane using the micro-CT when compared with histological sections remained within a 16% error. This is because of the scattering effect of the metallic membrane and the impossibility to distinguish newly formed bone from the original skull bone on the micro-CT images.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [1] Evaluation of Osseointegration of Titanium Alloyed Implants: A Comparison of Micro-computed Tomography and Histomorphometry
    Gabler, Carolin
    Zietz, Carmen
    Bieck, Richard
    Goehler, Rebecca
    Bader, Rainer
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1132 - S1132
  • [2] Comparison of micro-computed tomography and histomorphometry in the measurement of bone-implant Contact ratios
    Choi, Jung-Yoo
    Park, Jae-Il
    Chae, Ji Soo
    Yeo, In-Sung Luke
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (01): : 87 - 95
  • [3] Histomorphometry and micro-computed tomography on human bone biopsies:: Comparison insight measurements.
    Chappard, D
    Legrand, E
    Audran, M
    Baslé, MF
    JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 : S469 - S469
  • [4] A comparison of microstructure of trabecular bone between micro-computed tomography and conventional histomorphometry.
    Uchiyama, T
    Tanizawa, T
    Tokunaga, K
    Nishida, S
    Endo, N
    Takahashi, HE
    Ito, M
    Saito, S
    Hara, T
    JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 : T698 - T698
  • [5] The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography
    Schouten, Corinne
    Meijer, Gert J.
    van den Beucken, Jeroen J. J. P.
    Spauwen, Paul H. M.
    Jansen, John A.
    BIOMATERIALS, 2009, 30 (27) : 4539 - 4549
  • [6] Utilizing micro-computed tomography to evaluate bone structure surrounding dental implants: A comparison with histomorphometry
    Vandeweghe, Stefan
    Coelho, Paulo G.
    Vanhove, Christian
    Wennerberg, Ann
    Jimbo, Ryo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101 (07) : 1259 - 1266
  • [7] Characterisation of the influence of dietary fat and sugar on bone health utilising densitometry, micro-computed tomography and histomorphometry
    Khan, J.
    Sadie-Van Gijsen, H.
    Kotze-Horstmann, L. M.
    Kotze, S. H.
    Layman-Lemphane, J. I.
    BONE, 2025, 192
  • [8] Hierarchical structure of bone and micro-computed tomography
    McCreadie, BR
    Goulet, RW
    Feldkamp, LA
    Goldstein, SA
    NONINVASIVE ASSESSMENT OF TRABECULAR BONE ARCHITECTURE AND THE COMPETENCE OF BONE, 2001, 496 : 67 - 83
  • [9] Correlation between micro-computed tomography and histomorphometry for assessment of new bone formation in a calvarial experimental model
    Yeom, Heyri
    Blanchard, Steven
    Kim, SeokJin
    Zunt, Susan
    Chu, Tien-Min G.
    JOURNAL OF CRANIOFACIAL SURGERY, 2008, 19 (02) : 446 - 452
  • [10] Micro-computed tomography and compressive characterization of trabecular bone
    Catarina Vale, A.
    Pereira, M. F. C.
    Mauricio, A.
    Amaral, P.
    Rosa, L. G.
    Lopes, A.
    Rodrigues, A.
    Caetano-Lopes, J.
    Vidal, B.
    Monteiro, J.
    Fonseca, J. E.
    Canhao, H.
    Fatima Vaz, M.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 438 : 199 - 205