Real-time continuous glucose monitoring together with telemedical assistance improves glycemic control and glucose stability in pump-treated patients

被引:24
作者
Rigla, Mercedes [1 ,2 ]
Hernando, M. Elena [2 ,3 ]
Gomez, Enrique J. [2 ,3 ]
Brugues, Eulalia [1 ]
Garcia-Saez, Gema [3 ]
Capel, Ismael [1 ]
Pons, Belen [1 ]
de Leiva, Alberto [1 ,2 ]
机构
[1] Hosp Santa Creu & Sant Pau, Barcelona 08025, Spain
[2] CIBER BBN, Network Res Bioengn Biomat & Nanomed, Barcelona, Spain
[3] Univ Politecn Madrid, Bioengn & Telemed Grp, Madrid, Spain
关键词
D O I
10.1089/dia.2007.0273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Real-time continuous glucose monitoring (CGM) has recently been incorporated into routine diabetes management because of the potential advantages it offers for glycemic control. The aim of our study was to evaluate the impact of the use of real-time CGM together with a telemedicine system in hemoglobin A1c and glucose variability in patients with type 1 diabetes treated with insulin pumps. Methods: Ten patients (five women, 41.2 [range, 21-62] years old, duration of diabetes 14.9 [range, 3-52] years) were included in this randomized crossover study. Patients used the DIABTel telemedicine system throughout the study, and real-time CGM was used for 3 days every week during the intervention phase. At the end of the control phase, a blind 3-day CGM was performed. Glucose variability was evaluated using the Glucose Risk Index (GRI), a comparative analysis of continuous glucose values over two consecutive hours. Results: Hemoglobin A1c decreased significantly (8.1 +/- 1.1% vs. 7.3 +/- 0.8%; P = 0.007) after the intervention phase, while no changes were observed during the control phase. The mean number of daily capillary glucose readings was higher during the intervention phase (4.7 +/- 1.1 vs. 3.8 +/- 1.0; P < 0.01), because of an increase in random analyses (1.22 +/- 0.3 vs. 0.58 +/- 0.1; P < 0.01), and there was also a significant increase in the mean number of bolus doses per day (5.23 +/- 1.1 vs. 4.4 +/- 0.8; P < 0.05). The GRI was higher during the control phase than during the experimental phase (9.6 vs. 6.25; P < 0.05). Conclusions: Real-time CGM in conjunction with the DIABTel system improves glycemic control and glucose stability in pump-treated patients with type 1 diabetes.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 21 条
[1]   Reduction in hemoglobin A1c with real-time continuous glucose monitoring: Results from a 12-week observational study [J].
Bailey, Timothy S. ;
Zisser, Howard C. ;
Garg, Satish K. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2007, 9 (03) :203-210
[2]   The effect of glucose variability on the risk of microvascular complications in type 1 diabetes - Response to Monnier et al., the Diabetes Research in Children Network (DirecNet) Study Group, and Irsch and Brownlee [J].
Bolli, Geremia B. ;
Gerstein, Hertzel C. ;
Rosenstock, Julio .
DIABETES CARE, 2007, 30 (01) :188-189
[3]   Glucose variability and complications [J].
Bolli, Geremia B. .
DIABETES CARE, 2006, 29 (07) :1707-1709
[4]   Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring [J].
Deis, Dorothee ;
Bolinder, Jan ;
Riveline, Jean-Pierre ;
Battelino, Tadej ;
Bosi, Emanuele ;
Tubiana-Rufi, Nadia ;
Kerr, David ;
Phillip, Moshe .
DIABETES CARE, 2006, 29 (12) :2730-2732
[5]   Relative inaccuracy of the A1cNow in children with type 1 diabetes [J].
Fox, Larry ;
Dontchev, Mariya ;
Ruedy, Katrina ;
Beck, Roy ;
Kollman, Craig ;
Messer, Laurel ;
Coffey, Julie ;
Wilson, Darrell ;
Doyle, Elizabeth ;
Tamborlane, William ;
Steffes, Michael .
DIABETES CARE, 2007, 30 (01) :135-137
[6]   Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor [J].
Garg, S ;
Zisser, H ;
Schwartz, S ;
Bailey, T ;
Kaplan, R ;
Ellis, S ;
Jovanovic, L .
DIABETES CARE, 2006, 29 (01) :44-50
[7]   Relationship of fasting and hourly glucose levels to HbA1c values blood [J].
Garg, Satish ;
Jovanovic, Lots .
DIABETES CARE, 2006, 29 (12) :2644-2649
[8]  
GOMEZ EJ, 2005, COMPUT METH PROG BIO, V69, P163
[9]   A pilot trial in pediatrics with the sensor-augmented pump: Combining real-time continuous glucose monitoring with the insulin pump [J].
Halvorson, Mary ;
Carpenter, Sue ;
Kaiserman, Kevin ;
Kaufman, Francine R. .
JOURNAL OF PEDIATRICS, 2007, 150 (01) :103-105
[10]   Should minimal blood glucose variability become the gold standard of glycemic control? [J].
Hirsch, IB ;
Brownlee, M .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2005, 19 (03) :178-181