Long-term outcomes of standard endovascular aneurysm repair in patients with severe neck angulation

被引:38
|
作者
Oliveira, Nelson F. G. [1 ,2 ]
Goncalves, Frederico Bastos [1 ,3 ]
Hoeks, Sanne E. [4 ]
van Rijn, Marie Josee [1 ]
Ultee, Klaas [1 ]
Pinto, Jose Pedro [1 ,5 ]
Ten Raa, Sander [1 ]
van Herwaarden, Joost A. [6 ]
de Vries, Jean-Paul P. M. [7 ]
Verhagen, Hence J. M. [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Vasc Surg, Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Anesthesiol, Rotterdam, Netherlands
[3] Hosp Divino Espirito Santo, Dept Angiol & Vasc Surg, Ponta Delgada, Azores, Portugal
[4] Ctr Hosp Lisboa Cent, Hosp Santa Marta, Dept Angiol & Vasc Surg, Lisbon, Portugal
[5] Hosp Sao Joao, Dept Angiol & Vasc Surg, Porto, Portugal
[6] Univ Med Ctr Utrecht, Dept Vasc Surg, Utrecht, Netherlands
[7] St Antonius Hosp, Dept Vasc Surg, Nieuwegein, Netherlands
关键词
Aortic aneurysm; Abdominal; Blood vessel prosthesis implantation; Severe aortic neck angulation; Long-term follow-up; Endurant stent graft; Retrospective studies; ABDOMINAL AORTIC-ANEURYSM; ENDURANT STENT-GRAFT; HOSTILE; TRIAL; COMPLICATIONS; PREDICTORS; CURVATURE; CRITERIA;
D O I
10.1016/j.jvs.2018.03.427
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Severe neck angulation is associated with complications after endovascular aneurysm repair (EVAR). Newer endografts may overcome this limitation, but the literature lacks long-term results. We studied the long-term outcomes of EVAR in patients with severe neck angulation. Methods: A retrospective case-control study of a prospective multicenter database was performed. All measurements were made with dedicated software with center lumen line reconstruction. A study group including patients with neck length >15 mm, infrarenal angle (beta) > 75 degrees or suprarenal angle (alpha) > 60 degrees, and neck length 10 to 15 mm with beta > 60 degrees or alpha > 45 degrees was compared with a control group matched for demographics and other morphologic neck features. The primary end point was type IA endoleak (EL1A). Secondary end points were freedom from neck-related secondary interventions, primary clinical success, and overall survival. Results: Forty-five patients were included in the angulated neck group and compared with 65 matched patients. Median follow-up was 7.4 years (interquartile range, 4.8-8.5 years). In the angulated neck group, mean a was 51.4 degrees (+/-21.1 degrees) and the mean beta was 80.8 degrees (+/-15.6 degrees); in the nonangulated group, these were 17.9 degrees (+/-17.0 degrees) and 35.4 degrees (+/-20.0 degrees), respectively. At 7 years, five patients in the angulated neck group and two nonangulated patients developed EL1A, yielding a freedom from EL1A of 86.1% (n = 14; standard error [SE], 0.069) and 96.6% (n = 34; SE, 0.023), respectively (P =.056). After exclusion of a patient who developed an EL1A secondary to an endograft infection, this difference was significant: 86.1% (n = 14; SE, 0.069) in the angulated neck group and 98.2% (n = 34; SE, 0.018) in the nonangulated group (P =.016). At 7 years, freedom from neck-related secondary interventions was 91.7% (n = 14; SE, 0.059) and 91.6% (n = 29; SE, 0.029), respectively. The 7-year primary clinical success estimates were 41.2% (n = 11; SE, 0.085) and 56.6% (n = 20; SE, 0.072) for the angulated neck and nonangulated groups, respectively (P =.12). The 7-year survival rates were 44.3% (n = 18; SE, 0.076) vs 66.7% (n = 42; SE, 0.059) for the angulated neck and nonangulated groups, respectively (P =.25). Device integrity failure was not observed. Conclusions: Despite satisfactory results early and in the midterm, a higher rate of EL1A was identified among patients with severely angulated necks in the long term. However, mortality was not affected by this difference. These findings suggest that EVAR should be used judiciously in patients with extreme angulation of the proximal neck and highlight the need for close follow-up of EVAR, especially in the long term and in patients treated outside instructions for use.
引用
收藏
页码:1725 / 1735
页数:11
相关论文
共 50 条
  • [1] Impact of suprarenal neck angulation on endovascular aneurysm repair outcomes
    Mathlouthi, Asma
    Locham, Satinderjit
    Dakour-Aridi, Hanaa
    Black, James H.
    Malas, Mahmoud B.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (06) : 1900 - 1906
  • [2] Prognostic Role of Severe Infrarenal Aortic Neck Angulation in Endovascular Aneurysm Repair
    Qayyum, Haisum
    Hansrani, Vivak
    Antoniou, George A.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 62 (03) : 409 - 421
  • [3] Long-term results after standard endovascular aneurysm repair with the Endurant and Excluder stent grafts
    Oliveira-Pinto, Jose
    Oliveira, Nelson F. G.
    Bastos-Goncalves, Frederico M.
    Hoeks, Sanne
    Van Rijn, Marie Josee
    Ten Raa, Sander
    Mansilha, Armando
    Verhagen, Hence J. M.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) : 64 - 74
  • [4] Patients with large neck diameter have a higher risk of type IA endoleaks and aneurysm rupture after standard endovascular aneurysm repair
    Oliveira, Nelson F. G.
    Goncalves, Frederico Bastos
    Ultee, Klaas
    Pinto, Jose Pedro
    van Rijn, Marie Jose
    Ten Raa, Sander
    Mwipatayi, Patrice
    Boeckler, Dittmar
    Hoeks, Sanne E.
    Verhagen, Hence J. M.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (03) : 783 - 791
  • [5] The Correlation of Aortic Neck Angle and Length in Abdominal Aortic Aneurysm with Severe Neck Angulation for Prediction of Intraoperative Neck Complications and Postoperative Outcomes after Endovascular Aneurysm Repair
    Chinsakchai, Khamin
    Sirivech, Thana
    Moll, Frans L.
    Tongsai, Sasima
    Hongku, Kiattisak
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [6] Evidence for endovascular aneurysm repair in patients with highly angulated neck anatomy
    Weale, A. R.
    Beckitt, T.
    Collin, N.
    Hardman, J.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2012, 53 (04) : 433 - 445
  • [7] Mid-Term Results of EVAR in Severe Proximal Aneurysm Neck Angulation
    Oliveira, N. F. G.
    Bastos Goncalves, F. M.
    de Vries, J. -P. P. M.
    Ultee, K. H. J.
    Werson, D. A. B.
    Hoeks, S. E.
    Moll, F.
    van Herwaarden, J. A.
    Verhagen, H. J. M.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (01) : 19 - 27
  • [8] Long-term outcomes and interventions of postoperative type 1a endoleak following elective endovascular aortic aneurysm repair
    Major, Matthew
    Long, Graham W.
    Eden, Christine L.
    Studzinski, Diane M.
    Callahan, Rose E.
    Brown, O. William
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (01) : 136 - +
  • [9] Long-term Outcomes of the Endurant and Excluder Stent Grafts for Endovascular Aneurysm Repair in a Japanese Cohort
    Sekimoto, Yasuhito
    Fujimura, Naoki
    Matsubara, Kentaro
    Uchida, Norio
    Asami, Atsunori
    Harada, Hirohisa
    Shintani, Tsunehiro
    Watada, Susumu
    Ono, Shigeshi
    Fujii, Taku
    Shimogawara, Tatsuya
    Hayashi, Keita
    Hayashi, Masanori
    Obara, Hideaki
    Kitagawa, Yuko
    JOURNAL OF ENDOVASCULAR THERAPY, 2023, 30 (04) : 571 - 579
  • [10] Thrombotic Occlusion of Stent Graft Limbs due to Severe Angulation of Aortic Neck in Endovascular Repair of Abdominal Aortic Aneurysm
    Kim, Minsu
    Kim, Myeong Gun
    Kang, Woong Chol
    Oh, Pyung Chun
    Lee, Ji Yeon
    Kang, Jin Mo
    Chung, Wook-Jin
    Shin, Eak Kyun
    KOREAN CIRCULATION JOURNAL, 2016, 46 (05) : 727 - 729