A comparative study between air cooling and liquid cooling thermal management systems for a high-energy lithium-ion battery module

被引:224
作者
Akbarzadeh, Mohsen [1 ,2 ,3 ]
Kalogiannis, Theodoros [1 ,2 ,3 ]
Jaguemont, Joris [1 ,2 ,3 ]
Jin, Lu [4 ]
Behi, Hamidreza [1 ,2 ,3 ]
Karimi, Danial [1 ,2 ,3 ]
Beheshti, Hamidreza [1 ,2 ,3 ]
Van Mierlo, Joeri [1 ,2 ,3 ]
Berecibar, Maitane [1 ,2 ,3 ]
机构
[1] Vrije Univ Brussel VUB, ETEC Dept, Pl Laan 2, B-1050 Brussels, Belgium
[2] Vrije Univ Brussel VUB, MOBI Res Grp, Pl Laan 2, B-1050 Brussels, Belgium
[3] Flanders Make, B-3001 Heverlee, Belgium
[4] Global Energy Interconnect Res Inst Europe GmbH, D-10623 Berlin, Germany
关键词
Battery thermal management; Electric vehicle; Air cooling; Liquid cooling; Parasitic power consumption; STRUCTURAL OPTIMIZATION; PRISMATIC BATTERY; HEAT-TRANSFER; DESIGN; PERFORMANCE; PACKS;
D O I
10.1016/j.applthermaleng.2021.117503
中图分类号
O414.1 [热力学];
学科分类号
摘要
The parasitic power consumption of the battery thermal management systems is a crucial factor that affects the specific energy of the battery pack. In this paper, a comparative analysis is conducted between air type and liquid type thermal management systems for a high-energy lithium-ion battery module. The parasitic power consumption and cooling performance of both thermal management systems are studied using computational fluid dynamics (CFD) simulations. The 48 V module investigated in this study is comprised of 12 prismatic-shape NMC batteries. An experimental test bench is built up to test the module without any cooling system under the natural convection at room temperature, and the numerical model of the module is validated with experimental results. Two different cooling systems for the module are then designed and investigated including a U-type parallel air cooling and a new indirect liquid cooling with a U-shape cooling plate. The influence of coolant flow rate and coolant temperature on the thermal behavior of the module is investigated for a 2C discharge process. It was found that for a certain amount of power consumption, the liquid type BTMS results in a lower module temperature and better temperature uniformity. As an example, for the power consumption of around 0.5 W, the average temperature of the hottest battery cell in the liquid-cooled module is around 3 degrees C lower than the aircooled module. The results of this research represent a further step towards the development of energyefficient battery thermal management systems.
引用
收藏
页数:15
相关论文
共 48 条
[1]   A novel liquid cooling plate concept for thermal management of lithium-ion batteries in electric vehicles [J].
Akbarzadeh, Mohsen ;
Jaguemont, Joris ;
Kalogiannis, Theodoros ;
Karimi, Danial ;
He, Jiacheng ;
Jin, Lu ;
Xie, Peng ;
Mierlo, Joeri Van ;
Berecibar, Maitane .
ENERGY CONVERSION AND MANAGEMENT, 2021, 231
[2]   Thermal modeling of a high-energy prismatic lithium-ion battery cell and module based on a new thermal characterization methodology [J].
Akbarzadeh, Mohsen ;
Kalogiannis, Theodoros ;
Jaguemont, Joris ;
He, Jiacheng ;
Jin, Lu ;
Berecibar, Maitane ;
Van Mierlo, Joeri .
JOURNAL OF ENERGY STORAGE, 2020, 32 (32)
[3]   Novel thermal management system using boiling cooling for high-powered lithium-ion battery packs for hybrid electric vehicles [J].
Al-Zareer, Maan ;
Dincer, Ibrahim ;
Rosen, Marc A. .
JOURNAL OF POWER SOURCES, 2017, 363 :291-303
[5]   PCM assisted heat pipe cooling system for the thermal management of an LTO cell for high-current profiles [J].
Behi, Hamidreza ;
Karimi, Danial ;
Gandoman, Foad Heidari ;
Akbarzadeh, Mohsen ;
Khaleghi, Sahar ;
Kalogiannis, Theodoros ;
Hosen, Md Sazzad ;
Jaguemont, Joris ;
Van Mierlo, Joeri ;
Berecibar, Maitane .
CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
[6]   Heat pipe air-cooled thermal management system for lithium-ion batteries: High power applications [J].
Behi, Hamidreza ;
Behi, Mohammadreza ;
Karimi, Danial ;
Jaguemont, Joris ;
Ghanbarpour, Morteza ;
Behnia, Masud ;
Berecibar, Maitane ;
Van Mierlo, Joeri .
APPLIED THERMAL ENGINEERING, 2021, 183 (183)
[7]   A new concept of thermal management system in Li-ion battery using air cooling and heat pipe for electric vehicles [J].
Behi, Hamidreza ;
Karimi, Danial ;
Behi, Mohammadreza ;
Ghanbarpour, Morteza ;
Jaguemont, Joris ;
Sokkeh, Mohsen Akbarzadeh ;
Gandoman, Foad Heidari ;
Berecibar, Maitane ;
Van Mierlo, Joeri .
APPLIED THERMAL ENGINEERING, 2020, 174
[8]  
Bernardi D., 1970, A General Energy Balance for Battery Systems, P132
[9]   Comparison of different cooling methods for lithium ion battery cells [J].
Chen, Dafen ;
Jiang, Jiuchun ;
Kim, Gi-Heon ;
Yang, Chuanbo ;
Pesaran, Ahmad .
APPLIED THERMAL ENGINEERING, 2016, 94 :846-854
[10]   Effects of different phase change material thermal management strategies on the cooling performance of the power lithium ion batteries: A review [J].
Chen, Jingwei ;
Kang, Siyi ;
Jiaqiang, E. ;
Huang, Zhonghua ;
Wei, Kexiang ;
Zhang, Bin ;
Zhu, Hao ;
Deng, Yuanwang ;
Zhang, Feng ;
Liao, Gaoliang .
JOURNAL OF POWER SOURCES, 2019, 442