Graft materials provide greater static strength to medial opening wedge high tibial osteotomy than when no graft is included

被引:14
作者
Belsey, James [1 ,5 ]
Kaze, Arnaud Diffo [2 ,3 ]
Jobson, Simon [1 ]
Faulkner, James [1 ]
Maas, Stefan [2 ]
Khakha, Raghbir [5 ]
Wilson, Adrian J. [4 ]
Pape, Dietrich [3 ]
机构
[1] Univ Winchester, Dept Sport Exercise & Hlth, Sparkford Rd, Winchester SO22 4NR, Hants, England
[2] Univ Luxembourg, Fac Sci Technol & Commun, 6 Rue R Coudenhove Kalergi, L-1359 Luxembourg, Luxembourg
[3] Ctr Hosp Luxembourg, Dept Orthopaed Surg, L-1460 Luxembourg, Luxembourg
[4] Hampshire Clin, Basing Rd, Basingstoke RG24 7AL, Hants, England
[5] Basingstoke & North Hampshire Hosp, Aldermaston Rd, Basingstoke RG24 9NA, Hants, England
关键词
Tibial osteotomy; Allograft; Synthetic graft; Biomechanical analysis; Static strength; Activmotion plate; FULL WEIGHT-BEARING; PLATE FIXATION; KNEE; TERM;
D O I
10.1186/s40634-019-0184-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The purpose of this study was to compare the stability of medial opening-wedge high tibial osteotomy (MOWHTO) with and without different graft materials. Good clinical and radiological outcomes have been demonstrated when either using or not using graft materials during MOWHTO. Variations in the biomechanical properties of different graft types, regarding the stability they provide a MOWHTO, have not been previously investigated. Methods A 10 mm biplanar MOWHTO was performed on 15 artificial sawbone tibiae, which were fixed using the Activmotion 2 plate. Five bones had OSferion60 wedges (synthetic group), five had allograft bone wedges (allograft group), and five had no wedges (control group) inserted into the osteotomy gap. Static compression was applied axially to each specimen until failure of the osteotomy. Ultimate load, horizontal and vertical displacements were measured and used to calculate construct stiffness and valgus malrotation of the tibial head. Results The synthetic group failed at 6.3 kN, followed by the allograft group (6 kN), and the control group (4.5 kN). The most valgus malrotation of the tibial head was observed in the allograft group (2.6 degrees). The synthetic group showed the highest stiffness at the medial side of the tibial head (9.54 kN center dot mm(- 1)), but the lowest stiffness at the lateral side (1.59 kN center dot mm(-1)). The allograft group showed high stiffness on the medial side of the tibial head (7.54 kN center dot mm(- 1)) as well as the highest stiffness on the lateral side (2.18 kN center dot mm(- 1)). Conclusions The use of graft materials in MOWHTO results in superior material properties compared to the use of no graft. The static strength of MOWHTO is highest when synthetic grafts are inserted into the osteotomy gap. Allograft wedges provide higher mechanical strength to a MOWHTO than when no graft used. In comparison to the synthetic grafts, allograft wedges result in the stiffness of the osteotomy being more similar at the medial and lateral cortices.
引用
收藏
页数:9
相关论文
共 41 条
[1]   Results of high tibial osteotomy: review of the literature [J].
Amendola, Annunziato ;
Bonasia, Davide Edoardo .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (02) :155-160
[2]   Do we need synthetic osteotomy augmentation materials for opening-wedge high tibial osteotomy [J].
Aryee, Sebastian ;
Imhoff, Andreas B. ;
Rose, Tim ;
Tischer, Thomas .
BIOMATERIALS, 2008, 29 (26) :3497-3502
[3]   Prospective 5-year survival rate data following open-wedge valgus high tibial osteotomy [J].
Bode, Gerrit ;
von Heyden, Johanna ;
Pestka, Jan ;
Schmal, Hagen ;
Salzmann, Gian ;
Suedkamp, Norbert ;
Niemeyer, Philipp .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) :1949-1955
[4]   Early full weight bearing is safe in open-wedge high tibial osteotomy [J].
Brinkman, Justus-Martijn ;
Luites, Joan W. H. ;
Wymenga, Ate B. ;
van Heerwaarden, Ronald J. .
ACTA ORTHOPAEDICA, 2010, 81 (02) :193-198
[5]   Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: Prospective evaluation of bone union, precision and maintenance of correction in 51 cases [J].
Brosset, T. ;
Pasquier, G. ;
Migaud, H. ;
Gougeon, F. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (07) :705-711
[6]   A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate [J].
Cotic, Matthias ;
Vogt, Stephan ;
Hinterwimmer, Stefan ;
Feucht, Matthias J. ;
Slotta-Huspenina, Julia ;
Schuster, Tibor ;
Imhoff, Andreas B. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) :2032-2040
[7]   PROXIMAL TIBIAL OSTEOTOMY - A CRITICAL LONG-TERM STUDY OF 87 CASES [J].
COVENTRY, MB ;
ILSTRUP, DM ;
WALLRICHS, SL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02) :196-201
[8]  
Diffo Kaze A, 2016, THESIS U LUXEMBOURG
[9]   Static and fatigue strength of a novel anatomically contoured implant compared to five current open-wedge high tibial osteotomy plates [J].
Diffo Kaze A. ;
Maas S. ;
Belsey J. ;
Hoffmann A. ;
Pape D. .
Journal of Experimental Orthopaedics, 4 (1)
[10]   Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy [J].
Diffo Kaze A. ;
Maas S. ;
Waldmann D. ;
Zilian A. .
Journal of Experimental Orthopaedics, 2 (1) :1-17