Impact of Soong grading on flexor tendon ruptures following palmar plating for distal radial fractures

被引:19
作者
Goeren, Yekta [1 ]
Sauerbier, Michael [1 ]
Arsalan-Werner, Annika [1 ]
机构
[1] BG Trauma Ctr Frankfurt Am Main, Dept Plast Hand & Reconstruct Surg, Friedberger Landstr 430, D-60389 Frankfurt, Germany
关键词
Soong classification; distal radius fracture; palmar radius plate; plate removal; flexor pollicis longus rupture; FIXATION; REMOVAL; CLASSIFICATION;
D O I
10.1177/1753193419893561
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to evaluate flexor tendon injuries following palmar plating of distal radial fractures relative to the Soong grade. This retrospective cohort study included 113 patients who underwent palmar plate removal after a distal radial fracture between 2010 and 2016. In 13 patients, a greater than 50% injury of the flexor pollicis longus tendon was observed. Of these, nine patients were classified as Soong grade 2, four as Soong grade 1 and none as grade 0. The difference between the Soong groups was statistically significant (p = 0.006). Flexor tenosynovitis was present in eight patients (7%) and more likely in patients with a higher Soong grade (p = 0.026). We conclude that higher Soong grades are associated with significantly more flexor tendon complications. Therefore, elective removal of the palmar plate after union of the fracture should be considered in patients with Soong grades 1 and 2.
引用
收藏
页码:348 / 353
页数:6
相关论文
共 16 条
[1]   Flexor tendon injuries following plate fixation of distal radius fractures: A systematic review of the literature [J].
Asadollahi S. ;
Keith P.P.A. .
Journal of Orthopaedics and Traumatology, 2013, 14 (4) :227-234
[2]   Distal Radius Volar Plate Design and Volar Prominence to the Watershed Line in Clinical Practice: Comparison of Soong Grading of 2 Common Plates in 400 Patients [J].
Bergsma, Minke ;
Brown, Kimberly ;
Doornberg, Job ;
Sierevelt, Inger ;
Jaarsma, Ruurd ;
Jadav, Bhavin .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (10) :853-859
[3]   Comparative clinical study of locking screws versus smooth locking pegs in volar plating of distal radius fractures [J].
Boretto, J. G. ;
Pacher, N. ;
Giunta, D. ;
Gallucci, G. L. ;
Alfie, V. ;
De Carli, P. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (07) :755-760
[4]  
Cook Alyssa, 2020, Hand (N Y), V15, P692, DOI 10.1177/1558944718820956
[5]  
Creighton James J 3rd, 2020, Hand (N Y), V15, P414, DOI 10.1177/1558944718797347
[6]   Comparison of distal radius fracture intra-articular step reduction with volar locking plates and K wires: a retrospective review of quality and maintenance of fracture reduction [J].
Johnson, N. A. ;
Dias, J. J. ;
Wildin, C. J. ;
Cutler, L. ;
Bhowal, B. ;
Ullah, A. S. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (02) :144-150
[7]   Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation [J].
Kitay, Alison ;
Swanstrom, Morgan ;
Schreiber, Joseph J. ;
Carlson, Michelle G. ;
Nguyen, Joseph T. ;
Weiland, Andrew J. ;
Daluiski, Aaron .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (06) :1091-1096
[8]   Distal Radius Volar Locking Plate Design and Associated Vulnerability of the Flexor Pollicis Longus [J].
Limthongthang, Roongsak ;
Bachoura, Abdo ;
Jacoby, Sidney M. ;
Osterman, A. Lee .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (05) :852-860
[9]   Reliability of the Soong Classification for Volar Plate Position [J].
Lutsky, Kevin F. ;
Jimenez, Megan ;
Rivlin, Michael ;
Matzon, Jonas L. ;
Maltenfort, Mitchell ;
Beredjiklian, Pedro K. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (07) :E199-E202
[10]   Incidence of Hardware Removal Following Volar Plate Fixation of Distal Radius Fracture [J].
Lutsky, Kevin F. ;
Beredjiklian, Pedro K. ;
Hioe, Stephen ;
Bilello, Justin ;
Kim, Nayoung ;
Matzon, Jonas L. .