Characterization and evaluation of two-dimensional microfluidic chip-HPLC coupled to tandem mass spectrometry for quantitative analysis of 7-aminoflunitrazepam in human urine

被引:29
作者
Bai, Hsin-Yu [1 ]
Lin, Shu-Ling [1 ]
Chan, Shen-An
Fuh, Ming-Ren [1 ]
机构
[1] Soochow Univ, Dept Chem, Taipei, Taiwan
关键词
SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY-LC; WHOLE-BLOOD; FLUNITRAZEPAM; METABOLITES; BENZODIAZEPINES; SAMPLES; IDENTIFICATION; PROTEINS;
D O I
10.1039/c0an00355g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidic chip-based high-performance-liquid-chromatography coupled to mass spectrometry (chip-HPLC-MS) has been widely used in proteomic research due to its enhanced sensitivity. We employed a chip-HPLC-MS system for determining small molecules such as drug metabolites in biological fluids. This chip-HPLC-MS system integrates a microfluidic switch, a 2-dimensional column design including an enrichment column (160 nL) for sample pre-concentration and an analytical column for chromatographic separation, as well as a nanospray emitter on a single polyimide chip. In this study, a relatively large sample volume (500 nL) was injected into the enrichment column for pre-concentration and an additional 4 mu L of the initial mobile phase was applied to remove un-retained components from the sample matrix prior to chromatographic separation. The 2-dimensional column design provides the advantages of online sample concentration and reducing matrix influence on MS detection. 7-Aminoflunitrazepam (7-aminoFM2), a major metabolite of flunitrazepam (FM2), was determined in urine samples using the integrated chip-HPLC-MS system. The linear range was 0.1-10 ng mL(-1) and the method detection limit (signal-to-noise ratio of 3) was 0.05 ng mL(-1) for 7-aminoFM2. After consecutive liquid-liquid extraction (LLE) and solid-phase extraction (SPE), the chip-HPLC-MS exhibited high correlation between 7-aminoFM2 spiked Milli-Q water and 7-aminoFM2 spiked urine samples. This system also showed good precision (n = 5) and recovery for spiked urine samples at the levels of 0.1, 1.0, and 10 ng mL(-1). Intra-day and inter-day precision were 2.0-7.1% and 4.3-6.0%, respectively. Clinical urine samples were also analyzed by this chip-HPLC-MS system and acceptable relative differences (-1.3 to -13.0%) compared with the results using a GC-MC method were determined. Due to its high sensitivity and ease of operation, the chip-HPLC-MS system can be utilized for the determination of small molecules such as drug metabolites and neurotransmitters in biological fluids for clinical diagnosis.
引用
收藏
页码:2737 / 2742
页数:6
相关论文
共 46 条
[1]   Simultaneous determination of fifteen low-dosed benzodiazepines in human urine by solid-phase extraction and gas chromatography-mass spectrometry [J].
Borrey, D ;
Meyer, E ;
Lambert, W ;
Van Peteghem, C ;
De Leenheer, AP .
JOURNAL OF CHROMATOGRAPHY B, 2001, 765 (02) :187-197
[2]   A label-free internal standard method for the differential analysis of bioactive lupin proteins using nano HPLC-Chip coupled with Ion Trap mass spectrometry [J].
Brambilla, Francesca ;
Resta, Donatella ;
Isak, Ilena ;
Zanotti, Marco ;
Arnoldi, Anna .
PROTEOMICS, 2009, 9 (02) :272-286
[3]  
Buckenmaier S, 2008, LC GC EUR, P25
[4]   Rapid analysis of benzodiazepines in whole blood by high-performance liquid chromatography: use of a monolithic column [J].
Bugey, A ;
Staub, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (03) :555-562
[5]   HPLC-CHIP coupled to a triple quadrupole mass spectrometer for carbonic anhydrase II quantification in human serum [J].
Callipo, Luciano ;
Foglia, Patrizia ;
Gubbiotti, Riccardo ;
Samperi, Roberto ;
Lagana, Aldo .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (03) :811-820
[6]   Separation efficiency of particle-packed HPLC microchips [J].
Ehlert, Steffen ;
Kraiczek, Karsten ;
Mora, Jose-Angel ;
Dittmann, Monika ;
Rozing, Gerard P. ;
Tallarek, Ulrich .
ANALYTICAL CHEMISTRY, 2008, 80 (15) :5945-5950
[7]   Studying Protein Phosphorylation in Low MW CSF Fractions with capLC-ICPMS and nanoLC-CHIP-ITMS for Identification of Phosphoproteins [J].
Ellis, Jenny ;
Grimm, Rudolf ;
Clark, Joseph F. ;
Pyne-Gaithman, Gail ;
Wilbur, Steve ;
Caruso, Joseph A. .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (11) :4736-4742
[8]   Electroosmosis- and pressure-driven chromatography in chips using continuous beds [J].
Ericson, C ;
Holm, J ;
Ericson, T ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :81-87
[9]   Fast analysis of isobaric grape anthocyanins by Chip-liquid chromatography/mass spectrometry [J].
Flamini, Riccardo ;
De Rosso, Mirko ;
Smaniotto, Anna ;
Panighel, Annarita ;
Vedova, Antonio Dalla ;
Seraglia, Roberta ;
Traldi, Pietro .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (18) :2891-2896
[10]   Urinary Detection Times and Excretion Patterns of Flunitrazepam and its Metabolites After A Single Oral Dose [J].
Forsman, Malin ;
Nystrom, Ingrid ;
Roman, Markus ;
Berglund, Liselotte ;
Ahlner, Johan ;
Kronstrand, Robert .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (08) :491-501