Anterior Chamber and Lens Position before and after Phacoemulsification According to Axial Length

被引:1
|
作者
Jung, Suk Hoon [1 ]
Kim, Seonjoo [1 ]
Chung, So Hyang [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol, Seoul, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2020年 / 61卷 / 01期
关键词
Anterior chamber depth; Axial length; Intraocular lens; Long; Short; OPTICAL COHERENCE TOMOGRAPHY; DEPTH; POWER; CATARACT; BIOMETRY; PENTACAM; REPEATABILITY; EYES;
D O I
10.3341/jkos.2020.61.1.17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In this study, we evaluated changes in the anterior chamber structure and lens position before and after phacoemulsification in eyes grouped by axial length (AL). Methods: This study included 65 eyes (16 short eyes [AL < 22.5 mm], 33 normal eyes [22.5 mm < AL < 25.0 mm], and 16 long eyes [AL > 25.5 mm]) that underwent cataract surgery. Pre- and postoperative anterior chamber depth (ACD) was measured using Pentacam (R) and IOL Master (R). In addition, we evaluated the anterior chamber angle (ACA), anterior chamber volume (ACV), epithelium-iris distance, and iris-lens (intraocular lens [IOL]) distance. Results: The change in ACD was significantly smaller in long eyes (Pentacam (R), p = 0.000; IOL Master (R), p = 0.001). The change in ACA was significantly larger in short eyes (p = 0.000), and the change in ACV was significantly smaller in long eyes (p = 0.000). The change in the epithelium-iris distance was significantly smaller in long eyes (p = 0.000), and the change in the iris-lens (IOL) distance was significantly smaller in short eyes (p = 0.000). Conclusions: In short eyes, changes in ACD, ACA, and ACV were found to be larger than those of other groups as the iris moved backward. In long eyes, greater backward movement of the IOL was observed. Therefore, the appropriate IOL power should be chosen, considering the postoperative position of the IOL during cataract surgery of short and long eyes.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [41] Predictive Accuracy of Intraocular Lens Formulas Calculated by Biometers with Multiple Refractive Indices According to Axial Length
    Won, Yeo Kyoung
    Yoo, Young-Sik
    Yun, Hee-jee
    Chung, Tae-Young
    Lim, Dong Hui
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (22)
  • [42] Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens
    Takagi, Yuki
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    PLOS ONE, 2020, 15 (11):
  • [43] Change in central corneal thickness, corneal endothelial cell density, anterior chamber depth and axial length after repair of rhegmatogenous retinal detachment
    Mukhtar, Ahsan
    Mehboob, Mohammad Asim
    Babar, Zaheer Uddin
    Ishaq, Mazhar
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (06) : 1412 - 1417
  • [44] Assessment of anterior chamber angle changes after phacoemulsification with swept-source OCT
    Zheng, Qian
    Hu, Man
    Li, Zhang-Liang
    Chang, Ping-Jun
    Zhao, Yun-E
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (10) : 1527 - 1532
  • [45] Anterior chamber parameters measured by the Pentacam CES after uneventful phacoemulsification in normotensive eyes
    Ucakhan, Ozlenen O.
    Ozkan, Muhip
    Kanpolat, Ayfer
    ACTA OPHTHALMOLOGICA, 2009, 87 (05) : 544 - 548
  • [46] Association of biometric factors with anterior chamber angle widening and intraocular pressure reduction after uneventful phacoemulsification for cataract
    Huang, Guofu
    Gonzalez, Eduardo
    Lee, Roland
    Chen, Yi-Chun
    He, Mingguang
    Lin, Shan C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01): : 108 - 116
  • [47] Anterior Segment Characteristics of Eyes with Anterior Chamber Depth Less than 2.8 mm and Axial Length Greater than 25 mm
    Niu, Lingling
    Luo, Xiumei
    Chen, Xueli
    Wang, Xiaoying
    Zhou, Xingtao
    Qian, Yishan
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (02) : 1195 - 1206
  • [48] Microbial contamination of the anterior chamber during cataract phacoemulsification and intraocular lens implantation in dogs
    Ledbetter, EC
    Millichamp, NJ
    Dziezyc, J
    VETERINARY OPHTHALMOLOGY, 2004, 7 (05) : 327 - 334
  • [49] Effects of Axial Length and Anterior Chamber Depth on Intrascleral Fixation Using a Fibrin Adhesive
    Son, Hyeon Woo
    Park, Jung Min
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (05): : 656 - 664
  • [50] Effect of strabismus surgery on ocular axial length, anterior chamber depth, and intraocular pressure
    Lee, Donghun
    Kim, Myung Mi
    Kim, Won Jae
    MEDICINE, 2019, 98 (22)