Anterior Chamber and Lens Position before and after Phacoemulsification According to Axial Length

被引:1
|
作者
Jung, Suk Hoon [1 ]
Kim, Seonjoo [1 ]
Chung, So Hyang [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Ophthalmol, Seoul, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2020年 / 61卷 / 01期
关键词
Anterior chamber depth; Axial length; Intraocular lens; Long; Short; OPTICAL COHERENCE TOMOGRAPHY; DEPTH; POWER; CATARACT; BIOMETRY; PENTACAM; REPEATABILITY; EYES;
D O I
10.3341/jkos.2020.61.1.17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In this study, we evaluated changes in the anterior chamber structure and lens position before and after phacoemulsification in eyes grouped by axial length (AL). Methods: This study included 65 eyes (16 short eyes [AL < 22.5 mm], 33 normal eyes [22.5 mm < AL < 25.0 mm], and 16 long eyes [AL > 25.5 mm]) that underwent cataract surgery. Pre- and postoperative anterior chamber depth (ACD) was measured using Pentacam (R) and IOL Master (R). In addition, we evaluated the anterior chamber angle (ACA), anterior chamber volume (ACV), epithelium-iris distance, and iris-lens (intraocular lens [IOL]) distance. Results: The change in ACD was significantly smaller in long eyes (Pentacam (R), p = 0.000; IOL Master (R), p = 0.001). The change in ACA was significantly larger in short eyes (p = 0.000), and the change in ACV was significantly smaller in long eyes (p = 0.000). The change in the epithelium-iris distance was significantly smaller in long eyes (p = 0.000), and the change in the iris-lens (IOL) distance was significantly smaller in short eyes (p = 0.000). Conclusions: In short eyes, changes in ACD, ACA, and ACV were found to be larger than those of other groups as the iris moved backward. In long eyes, greater backward movement of the IOL was observed. Therefore, the appropriate IOL power should be chosen, considering the postoperative position of the IOL during cataract surgery of short and long eyes.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [31] Effect of Anterior Chamber Depth on the Choice of Intraocular Lens Calculation Formula in Patients with Normal Axial Length
    Miraftab, Mohammad
    Hashemi, Hassan
    Fotouhi, Akbar
    Khabazkhoob, Mehdi
    Rezvan, Farhad
    Asgari, Soheila
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (04) : 307 - 311
  • [32] The measurement of anterior chamber depth and axial length with the IOLMaster compared with contact ultrasonic axial scan
    Bai, Quan-Hao
    Wang, Jun-Li
    Wang, Qing-Qiang
    Yan, Qi-Chang
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (02) : 151 - 154
  • [33] Influence of measurement differences of anterior chamber depth and axial length on lens thickness evaluation in cataract patients: a comparison of two tests
    Xu, Jiayi
    Li, Chen
    Wang, Lijun
    Li, Caixin
    Li, Xin
    Lu, Peirong
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [34] Influence of measurement differences of anterior chamber depth and axial length on lens thickness evaluation in cataract patients: a comparison of two tests
    Jiayi Xu
    Chen Li
    Lijun Wang
    Caixin Li
    Xin Li
    Peirong Lu
    BMC Ophthalmology, 20
  • [35] Effect of Anterior Chamber Instability during Phacoemulsification Combined with Intraocular Lens Implantation
    Geng, Wenjing
    Lin, Wenli
    Song, Pei
    Zhang, Min
    Wu, Jian
    Su, Shu
    Yuan, Yurong
    Ji, Min
    Guan, Huaijin
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [36] Anterior-Chamber Angle and Axial Length Measurements in Normal Chinese Children
    Jin, Peiyao
    Li, Meili
    He, Xiangui
    Lu, Lina
    Zhu, Jianfeng
    Chang, Ta Chen
    Zou, Haidong
    JOURNAL OF GLAUCOMA, 2016, 25 (08) : 692 - 697
  • [37] Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
    Gungor, Sirel Gur
    Akman, Ahmet
    Asena, Leyla
    Aksoy, Mustafa
    Sezenoz, Almila Sarigul
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2016, 46 (06): : 255 - 258
  • [38] Comparison of intraocular lens power formulas according to axial length after myopic corneal laser refractive surgery
    Whang, Woong-Joo
    Hoffer, Kenneth J.
    Kim, Seon-Ju
    Chung, So-Hyang
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (03): : 297 - 303
  • [39] Correlation between axial length and anterior chamber depth in short eyes, normal eyes, and long eyes
    El-Ghazawy, Rafik M. F.
    El-Awamry, Amr, I
    Zaki, Rania G.
    Aziz, Joseph H. F.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2019, 112 (01) : 30 - 33
  • [40] Effects of Residual Anterior Lens Epithelial Cell Removal on Axial Position of Intraocular Lens after Cataract Surgery
    Bang, Seung Pil
    Yoo, Young-Sik
    Jun, Jong Hwa
    Joo, Choun-Ki
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018