Risk-adjusted outcome analysis of endovascular abdominal aortic aneurysm repair in a large population: How do stent-grafts compare?

被引:103
作者
van Marrewijk, CJ
Leurs, LJ
Vallabhaneni, SR
Harris, PL
Buth, J
Laheij, RJF
机构
[1] Catharina Hosp, Dept Vasc Surg, Eindhoven, Netherlands
[2] Royal Liverpool Univ Hosp, Reg Vasc Unit, Liverpool, Merseyside, England
关键词
abdominal aortic aneurysm; endovascular repair; complications; adverse events; stent-graft failure; endoleak; mortality; rupture; outcome analysis;
D O I
10.1583/05-1530R.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To compare differences in the applicability and incidence of postoperative adverse events among stent-grafts used for repair of infrarenal aortic aneurysms. Methods: An analysis of 6787 patients from the EUROSTAR Registry database was conducted to compare aneurysm morphological features, patient characteristics, and postoperative events for the AneuRx, EVT/Ancure, Excluder, Stentor, Talent, and Zenith devices versus the Vanguard device (control) and each other. Annual incidence rates of complications were determined, and risks were compared using the Cox proportional hazards analysis. Results: The annual incidence rates were: device-related endoleak (types I and 111) 6% (range 4%-10%), type 11 endoleak 5% (range 0.3%-11%), migration 3% (range 0.5%-5%), kinking 2% (range 1%-5%), occlusion 3% (range 1%-5%), rupture 0.5% (range 0%-1%), and all-cause mortality 7% (range 5%-8%). After adjustment for factors influencing outcome, AneuRx, Excluder, Talent, and Zenith devices were associated with a lower risk of migration, kinking, occlusion, and secondary intervention compared to the Vanguard device. Significant increased risk for conversion (EVT/Ancure) and reduced risk of aneurysm rupture (AneuRx and Zenith) and all-cause mortality (Excluder) were found compared to the Vanguard device. Conclusions: Significant differences exist between stent-grafts of different labels in terms of applicability and complications during intermediate to long-term follow-up. Since each stent-graft has its drawbacks, no single label can be identified as the best. It is reassuring that developments in stent-grafts indeed result in better performance than the early stentgrafts. However, a single device incorporating all the perceived improvements should still be pursued.
引用
收藏
页码:417 / 429
页数:13
相关论文
共 37 条
[1]  
Ahn SS, 2000, SURGICAL AND ENDOVASCULAR TREATMENT OF AORTIC ANEURYSMS, P81
[2]   Endoleaks after endovascular repair of abdominal aortic aneurysms [J].
Baum, RA ;
Stavropoulos, SW ;
Fairman, RM ;
Carpenter, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (09) :1111-1117
[3]   Mid-term results of endovascular versus open repair for abdominal aortic aneurysm in patients anatomically suitable for endovascular repair [J].
Becquemin, JP ;
Bourriez, A ;
D'Audiffret, A ;
Zubilewicz, T ;
Kobeiter, H ;
Allaire, E ;
Mellière, D ;
Desgranges, P .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (06) :656-661
[4]   Abdominal aortic aneurysm size regression after endovascular repair is endograft dependent [J].
Bertges, DJ ;
Chow, K ;
Wyers, MC ;
Landsittel, D ;
Frydrych, AV ;
Stavropoulos, W ;
Tan, WA ;
Rhee, RY ;
Fillinger, MF ;
Fairman, RM ;
Makaroun, MS .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (04) :716-723
[5]   Early experience with the bifurcated Excluder endoprosthesis for treatment of the abdominal aortic aneurysm [J].
Bush, RL ;
Najibi, S ;
Lin, PH ;
Weiss, VJ ;
MacDonald, MJ ;
Redd, DC ;
Martin, LG ;
Chaikof, EL ;
Lumsden, AB .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (03) :497-502
[6]   Early complications and endoleaks after endovascular abdominal aortic aneurysm repair: Report of a multicenter study - Discussion [J].
Parodi, JC ;
Buth, J .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) :145-146
[7]   Predicting iliac limb occlusions after bifurcated aortic stent grafting: Anatomic and device-related causes [J].
Carroccio, A ;
Faries, PL ;
Morrissey, NJ ;
Teodorescu, V ;
Burks, JA ;
Gravereaux, EC ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (04) :679-684
[8]   Late abdominal aortic aneurysm enlargement after endovascular repair with the excluder device [J].
Cho, JS ;
Dillavou, ED ;
Rhee, RY ;
Makaroun, AS .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (06) :1236-1241
[9]   TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
FIORE, WM ;
DEWEESE, JA ;
QUERAL, LA ;
CRIADO ;
NATH, RL ;
BERKOWITZ, HD ;
SUMPIO, BE .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :185-197
[10]  
Criado FJ, 2001, J VASC SURG, V33, pS146