Outcome of mechanical circulatory support at the University Medical Centre Utrecht

被引:7
|
作者
Felix, S. E. A. [1 ]
Ramjankhan, F. Z. [2 ]
Buijsrogge, M. P. [2 ]
Jacob, K. A. [2 ]
Asselbergs, F. W. [1 ,3 ]
Oerlemans, M. I. F. [1 ]
Kirkels, J. H. [1 ]
van Laake, L. W. [1 ]
Oppelaar, A. M. C. [2 ]
Suyker, W. J. L. [2 ]
de Jonge, N. [1 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Cardiol, Div Heart & Lungs, Utrecht, Netherlands
[2] Univ Utrecht, Univ Med Ctr Utrecht, Dept Cardiothorac Surg, Utrecht, Netherlands
[3] UCL, Fac Populat Hlth Sci, Inst Hlth Informat, London, England
关键词
Mechanical circulatory support; Outcome; Complications; VENTRICULAR ASSIST DEVICE; STAGE HEART-FAILURE; EUROPEAN REGISTRY; TRANSPLANTATION; IMPLANTATION; VALIDATION; SOCIETY; FOCUS; PUMP;
D O I
10.1007/s12471-020-01375-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The prevalence of heart failure (HF) is increasing substantially and, despite improvements in medical therapy, HF still carries a poor prognosis. Mechanical circulatory support (MCS) by a continuous-flow left ventricular assist device (cf-LVAD) improves survival and quality of life in selected patients. This holds especially for the short-term outcome, but experience regarding long-term outcome is growing as the waiting time for heart transplantation is increasing due to the shortage of donor hearts. Here we present our results from the University Medical Centre Utrecht. Methods Data of all patients with a cf-LVAD implant between March 2006 and January 2018 were collected. The primary outcome was survival. Secondary outcomes included adverse events defined according to the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) definitions, described per patient year. Results A total of 268 patients (69% male, mean age 50& x202f;+/- 13 years) received a cf-LVAD. After a median follow-up of 542 (interquartile range 205-1044) days, heart transplantation had been performed in 82 (31%) patients, the cf-LVAD had been explanted in 8 (3%) and 71 (26%) had died. Survival at 1, 3 and 5 years was 83%, 72% and 57%, respectively, with heart transplantation, cf-LVAD explantation or death as the end-point. Death was most often caused by neurological complications (31%) or infection (20%). Major bleeding occurred 0.51 times and stroke 0.15 times per patient year. Conclusion Not only short-term results but also 5-year survival after cf-LVAD support demonstrate that MCS is a promising therapy as an extended bridge to heart transplantation. However, the incidence of several major complications still has to be addressed.
引用
收藏
页码:210 / 218
页数:9
相关论文
共 50 条
  • [1] Outcome of mechanical circulatory support at the University Medical Centre Utrecht
    S. E. A. Felix
    F. Z. Ramjankhan
    M. P. Buijsrogge
    K. A. Jacob
    F. W. Asselbergs
    M. I. F. Oerlemans
    J. H. Kirkels
    L. W. van Laake
    A. M. C. Oppelaar
    W. J. L. Suyker
    N. de Jonge
    Netherlands Heart Journal, 2020, 28 : 210 - 218
  • [2] Twelve years of circulatory extracorporeal life support at the University Medical Centre Utrecht
    Meuwese, C. L.
    Hermens, J. A.
    de Haan, M.
    Braithwaite, S. A.
    Ramjankhan, F.
    Buijsrogge, M. P.
    de Jonge, N.
    Kirkels, J. H.
    de Jong, M.
    Pasma, W.
    Vromen-Wijsman, J. L. P.
    Kraaijeveld, A. O.
    de Waal, E. E.
    Torn, E.
    Platenkamp, M.
    van der Heijden, J. J.
    Cremer, O. L.
    van Dijk, D.
    Donker, D. W.
    NETHERLANDS HEART JOURNAL, 2021, 29 (7-8) : 394 - 401
  • [3] Twelve years of circulatory extracorporeal life support at the University Medical Centre Utrecht
    C. L. Meuwese
    J. A. Hermens
    M. de Haan
    S. A. Braithwaite
    F. Ramjankhan
    M. P. Buijsrogge
    N. de Jonge
    J. H. Kirkels
    M. de Jong
    W. Pasma
    J. L. P. Vromen-Wijsman
    A. O. Kraaijeveld
    E. E. de Waal
    E. Torn
    M. Platenkamp
    J. J. van der Heijden
    O. L. Cremer
    D. van Dijk
    D. W. Donker
    Netherlands Heart Journal, 2021, 29 : 394 - 401
  • [4] Mid Term Results of Mechanical Circulatory Support in the Netherlands, a Single Centre Experience from the University Medical Centre Utrecht (UMCU)
    Felix, S. E.
    Ramjankhan, F. Z.
    de Heer, F.
    de Jonge, N.
    Buijsrogge, M. P.
    Suyker, W. J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S332 - S332
  • [5] Thirty years of heart transplantation at the University Medical Centre Utrecht
    A. Sammani
    A. M. Wind
    J. H. Kirkels
    C. Klöpping
    M. P. Buijsrogge
    F. Z. Ramjakhan
    F. W. Asselbergs
    N. de Jonge
    Netherlands Heart Journal, 2017, 25 : 516 - 523
  • [6] Thirty years of heart transplantation at the University Medical Centre Utrecht
    Sammani, A.
    Wind, A. M.
    Kirkels, J. H.
    Klopping, C.
    Buijsrogge, M. P.
    Ramjakhan, F. Z.
    Asselbergs, F. W.
    de Jonge, N.
    NETHERLANDS HEART JOURNAL, 2017, 25 (09) : 516 - 523
  • [7] Mechanical circulatory support: lessons from a single centre
    El-Banayosy, A.
    Posival, H.
    Minami, K.
    Arusoglu, L.
    Kizner, L.
    Breymann, T.
    Seifert, D.
    Koerner, M. M.
    Koertke, H.
    Fey, O.
    Koerfer, R.
    PERFUSION-UK, 1996, 11 (02): : 93 - 102
  • [8] Development of mechanical circulatory support devices at the University of Tokyo
    Abe, Yusuke
    Isoyama, Takashi
    Saito, Itsuro
    Mochizuki, Shuichi
    Ono, Minoru
    Nakagawa, Hidernoto
    Taniguchi, Noriyuki
    Mitsurnune, Noribiko
    Sugino, Ayaka
    Mitsui, Mie
    Takiura, Koki
    Ono, Toshiya
    Kouno, Akirnasa
    Chinzei, Tsuneo
    Takarnoto, Shinichi
    Imachi, Kou
    JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (02) : 60 - 70
  • [9] Development of mechanical circulatory support devices at the University of Tokyo
    Yusuke Abe
    Takashi Isoyama
    Itsuro Saito
    Shuichi Mochizuki
    Minoru Ono
    Hidemoto Nakagawa
    Noriyuki Taniguchi
    Norihiko Mitsumune
    Ayaka Sugino
    Mie Mitsui
    Koki Takiura
    Toshiya Ono
    Akimasa Kouno
    Tsuneo Chinzei
    Shinichi Takamoto
    Kou Imachi
    Journal of Artificial Organs, 2007, 10
  • [10] A SINGLE CENTRE EXPERIENCE OF THE IMPELLA MECHANICAL CIRCULATORY SUPPORT DEVICE
    Sapontis, J. S.
    Scott, P. S.
    Kumar, V. K.
    Philip, P. M.
    Melikian, N. M.
    Byrne, J. B.
    Rafal, R. D.
    Ajay, A. M. S.
    Hill, J. M. H.
    HEART, 2013, 99