Determination of the scale of segregation of low dose tablets using hyperspectral imaging

被引:12
作者
Ely, David R. [1 ]
Carvajal, M. Teresa [1 ]
机构
[1] Purdue Univ, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
NIR; Chemical imaging; Hyperspectroscopy; Scale of segregation; Low dose; BLEND UNIFORMITY; SPECTROSCOPY; HOMOGENEITY;
D O I
10.1016/j.ijpharm.2011.05.027
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In this work, near infrared (NIR) hyperspectral imaging was used to quantify the spatial distribution of drug in tablets containing tolmetin sodium dihydrate. Hyperspectral data cubes were generated by imaging the same spatial region of a sample while illuminated by a laser at a different wavelength for each image. Images were generated for wavelengths ranging from 1100 to 2200 nm. Ten tablets with concentrations ranging from 0.0 to 10.0% w/w tolmetin were imaged, and the scales of segregation were calculated for the tablets. Lactose anhydrous was used as the diluent, and all mixtures contained 0.5% magnesium stearate as a lubricant. This research has shown hyperspectral imaging to be viable tool for quantifying segregation of low dose drugs in tablets. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 10 条
[1]  
American Society for Testing Materials (ASTM), 2000, E165500 ASTM
[2]   Direct quantification and distribution assessment of major and minor components in pharmaceutical tablets by NIR-chemical imaging [J].
Amigo, Jose Manuel ;
Ravn, Carsten .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 37 (02) :76-82
[3]   THE DEFINITION AND MEASUREMENT OF SOME CHARACTERISTICS OF MIXTURES [J].
DANCKWERTS, PV .
APPLIED SCIENTIFIC RESEARCH SECTION A-MECHANICS HEAT CHEMICAL ENGINEERING MATHEMATICAL METHODS, 1952, 3 (04) :279-296
[4]   An investigation into low dose blend uniformity and segregation determination using NIR spectroscopy [J].
Ely, David ;
Chamarthy, Sai ;
Carvajal, M. Teresa .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2006, 288 (1-3) :71-76
[5]  
ENNIS BJ, 2006, MEAS POWD FLOW ITS A
[6]   Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity [J].
Hausman, DS ;
Cambron, RT ;
Sakr, A .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2005, 298 (01) :80-90
[7]  
JOHNSON MCR, 1975, PHARM ACTA HELV, V50, P60
[8]   Application of a fluorescence sensor for miniscale on-line monitoring of powder mixing kinetics [J].
Lai, CK ;
Cooney, CC .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (01) :60-70
[9]   Real time and noninvasive monitoring of dry powder blend homogeneity [J].
Lai, CK ;
Holt, D ;
Leung, JC ;
Cooney, CL ;
Raju, GK ;
Hansen, P .
AICHE JOURNAL, 2001, 47 (11) :2618-2622
[10]   An experimental investigation of effusivity as an indicator of powder blend uniformity [J].
Leonard, G. ;
Bertrand, F. ;
Chaouki, J. ;
Gosselin, P. M. .
POWDER TECHNOLOGY, 2008, 181 (02) :149-159