Gonioscopy-assisted Transluminal Trabeculotomy (GATT): Thermal Suture Modification With a Dye-stained Rounded Tip

被引:36
作者
Grover, Davinder S. [1 ]
Fellman, Ronald L. [1 ]
机构
[1] Glaucoma Associates Texas, 10740 N Cent Expressway,Suite 300, Dallas, TX 75231 USA
关键词
trabeculotomy; minimally invasive glaucoma surgery (MIGS); ab interno; GATT; gonioscopy-assisted transluminal trabeculotomy; OPEN-ANGLE GLAUCOMA; ILLUMINATED MICROCATHETER; CONGENITAL GLAUCOMA; TRABECULECTOMY; ABEXTERNO;
D O I
10.1097/IJG.0000000000000325
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. Patient: One patient was used as an example for this technique. Methods: Technique report. Results and Conclusions: The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.
引用
收藏
页码:501 / 504
页数:4
相关论文
共 11 条
[1]   360-DEGREES TRABECULOTOMY FOR PRIMARY CONGENITAL GLAUCOMA [J].
BECK, AD ;
LYNCH, MG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (09) :1200-1202
[2]  
CHIHARA E, 1993, OPHTHALMIC SURG LAS, V24, P735
[3]   Reduction of Intraocular Pressure Using a Modified 360-degree Suture Trabeculotomy Technique in Primary and Secondary Open-Angle Glaucoma: A Pilot Study [J].
Chin, Shinki ;
Nitta, Takuya ;
Shinmei, Yasuhiro ;
Aoyagi, Maiko ;
Nitta, Akari ;
Ohno, Shigeaki ;
Ishida, Susumu ;
Yoshida, Kazuhiko .
JOURNAL OF GLAUCOMA, 2012, 21 (06) :401-407
[4]   Circumferential Trabeculotomy With an Illuminated Microcatheter in Congenital Glaucomas [J].
Girkin, Christopher A. ;
Marchase, Nick ;
Cogen, Martin S. .
JOURNAL OF GLAUCOMA, 2012, 21 (03) :160-163
[5]   Gonioscopy-Assisted Transluminal Trabeculotomy, Ab Interno Trabeculotomy Technique Report and Preliminary Results [J].
Grover, Davinder S. ;
Godfrey, David G. ;
Smith, Oluwatosin ;
Feuer, William J. ;
de Oca, Ildamaris Montes ;
Fellman, Ronald L. .
OPHTHALMOLOGY, 2014, 121 (04) :855-861
[6]  
Harms H, 1970, Trans Ophthalmol Soc U K, V89, P491
[7]   Success Rates of Trabeculotomy for Steroid-Induced Glaucoma: A Comparative, Multicenter, Retrospective Cohort Study [J].
Iwao, Keiichiro ;
Inatani, Masaru ;
Tanihara, Hidenobu .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (06) :1047-1056
[8]   TRABECULOTOMY ABEXTERNO AND TRABECULECTOMY IN CONGENITAL AND ADULT-ONSET GLAUCOMA [J].
LUNTZ, MH ;
LIVINGSTON, DG .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1977, 83 (02) :174-179
[9]   An illuminated microcatheter for 360-degree trabeculectomy in congenital glaucoma: A retrospective case series [J].
Sarkisian, Steven R., Jr. .
JOURNAL OF AAPOS, 2010, 14 (05) :412-416
[10]  
SMITH R, 1960, Br J Ophthalmol, V44, P370, DOI 10.1136/bjo.44.6.370