CNT encapsulated MnOx for an enhanced flow-through electro-Fenton process: the involvement of Mn(IV)

被引:27
|
作者
Guo, Dongli [1 ]
Jiang, Shengtao [2 ]
Jin, Limin [1 ]
Huang, Kui [3 ]
Lu, Ping [4 ]
Liu, Yanbiao [1 ,5 ]
机构
[1] Donghua Univ, Text Pollut Controlling Engn Ctr, Minist Environm Protect, Coll Environm Sci & Engn, Shanghai 201620, Peoples R China
[2] Taizhou Univ, Coll Life Sci, Taizhou 318000, Peoples R China
[3] Guangxi Univ, Sch Resources Environm & Mat, 100 Daxue Rd, Nanning 530004, Peoples R China
[4] Donghua Univ, Res Ctr Anal & Measurement, Shanghai 201620, Peoples R China
[5] Shanghai Inst Pollut Control & Ecol Secur, 1239 Siping Rd, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
CARBON NANOTUBE MEMBRANE; WASTE-WATER TREATMENT; OXYGEN REDUCTION; H2O2; DEGRADATION; MICROPOLLUTANTS; CATALYSIS; REMOVAL; OXIDE;
D O I
10.1039/d2ta03445j
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study reports a nanoconfined flow-through electro-Fenton system for highly efficient degradation of aqueous micropollutants. The key to such a system is a functional electroactive carbon nanotube (CNT) cathodic filter with encapsulated MnOx nanoparticles (MnOx-in-CNT). The nanohybrid filter, assisted by an electric field, generated hydrogen peroxide (H2O2) in situ, followed by its subsequent conversion to reactive oxygen species (ROS) accompanied by the redox cycling of Mn(IV)/Mn(III). Compared with the filter consisting of MnOx coated on the surface of CNT (MnOx-out-CNT), the MnOx-in-CNT filter demonstrated a 2.9 times higher k(L) value (0.050 min(-1) vs. 0.017 min(-1)) toward the degradation of bisphenol A (BPA). Density functional theory (DFT) computation and experimental studies revealed that the dominant ROS in the confined MnOx-in-CNT system were high-valent metal-oxo species (Mn(IV)) rather than the traditional hydroxyl or superoxide radicals in the unconfined MnOx-out-CNT system. The flow-through configuration outperformed a conventional batch reactor in BPA degradation due to convection-enhanced mass transport. These findings may provide a novel strategy for environmental remediation using highly efficient and integrated systems based on materials science, Fenton chemistry, and microfiltration techniques.
引用
收藏
页码:15981 / 15989
页数:10
相关论文
共 50 条
  • [21] Fabrication of FeOCl nanoparticles modified microchannel carbon cathode for flow-through electro-Fenton degradation of refractory organic pollutants
    Wang, Lei
    Wu, Shuai
    Chen, Hui
    Mao, Wei
    Kang, Wenda
    Chen, Shuo
    Yu, Hongtao
    Quan, Xie
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 288
  • [22] A coupled system of flow-through electro-Fenton and electrosorption processes for the efficient treatment of high-salinity organic wastewater
    Chai, Youzheng
    Qin, Pufeng
    Wu, Zhibin
    Bai, Ma
    Li, Wenjie
    Pan, Jiajia
    Cao, Ruoyu
    Chen, Anwei
    Jin, Doudou
    Peng, Cheng
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 267
  • [23] Study of the performance of a cylindrical flow-through electro-Fenton reactor using different arrangements of carbon felt electrodes: effect of key operating parameters
    Daniel Garcia-Espinoza, Josue
    Robles, Irma
    Duran-Moreno, Alfonso
    Godinez, Luis A.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (28) : 42305 - 42318
  • [24] The mechanism of Co-based carbon felt flow-through cathode non-homogeneous electro-Fenton system for organic pollutants degradation
    Yang, Jixiang
    Cai, Jingju
    Liu, Jiahao
    Xie, Qingrong
    Ding, Ziyi
    Han, Jing
    Zhou, Yufei
    Zhu, Jian
    JOURNAL OF WATER PROCESS ENGINEERING, 2025, 71
  • [25] Continuous flow-through electro-Fenton membrane reactor with Fe-N4-doped carbon membrane as cathode for efficient removal of dimethylacetamide
    Zhu, Yuxuan
    Chen, Zishang
    Wang, Hong
    Ma, Aijing
    Li, Jianxin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 354
  • [26] Flow-through heterogeneous electro-Fenton based on Co-CNT/Ti3C2TX membrane for improved tetracycline removal in wide pH ranges
    Zhang, Peng
    Wang, Yiran
    Luo, Xiaomin
    Wang, Jian
    Wang, Wenqi
    Duan, Xubin
    Qi, Kai
    Li, Meng
    ENVIRONMENTAL SCIENCE-NANO, 2022, 9 (12) : 4468 - 4483
  • [27] On-site Hydrogen Peroxide Production at Pilot Flow Plant: Application to Electro-Fenton Process
    Isarain-Chavez, Eloy
    de la Rosa, Catalina
    Martinez-Huitle, Carlos A.
    Peralta-Hernandez, Juan M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (03): : 3084 - 3094
  • [28] Flow-through heterogeneous electro-Fenton system based on the absorbent cotton derived bulk electrode for refractory organic pollutants treatment
    Wang, Xin
    Cao, Peike
    Zhao, Kun
    Chen, Shuo
    Yu, Hongtao
    Quan, Xie
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 276
  • [29] A review of the flow-through electro-catalytic water treatment process
    Li, Jiahui
    Li, Dong
    Liu, Cui
    Shi, Wei
    Yu, Jianghua
    Chen, Mindong
    Ma, Jun
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 365
  • [30] Enhanced in situ production of Fenton reagent's by nanobubble aeration and sacrificial iron anodes in the electro-Fenton process
    He, Siyuan
    Zhao, Siao
    Chen, Ziming
    Li, Xiaoqiang
    Ma, Yulong
    Ren, Yongsheng
    Duan, Xiaoxiao
    ELECTROCHEMISTRY COMMUNICATIONS, 2024, 158