Detection of cardiac right-to-left shunts by contrast-enhanced harmonic carotid duplex sonography

被引:14
作者
Draganski, B
Blersch, W
Holmer, S
Koch, H
May, A
Bogdahn, U
Hölscher, T
Schlachetzki, F
机构
[1] Univ Regensburg, Dept Neurol, D-8400 Regensburg, Germany
[2] Univ Regensburg, Dept Cardiol, D-8400 Regensburg, Germany
关键词
cardiac right-to-left shunt; extracranial duplex sonography; harmonic imaging; stroke;
D O I
10.7863/jum.2005.24.8.1071
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Paradoxical embolization by cardiac right-to-left shunts (RLS) is increasingly recognized as an important factor for embolic stroke. Contrast-enhanced transcranial Doppler sonography (ce-TCDS) is an established diagnostic tool for RLS detection but is frequently limited because of an inadequate temporal acoustic bone window. The purpose of this study was to determine whether extracranial sonography (ECS) using harmonic frequencies improves detection of RLS. Methods. Extracranial color duplex sonography using harmonic frequencies enables visualization of even single ultrasound contrast agent microbubbles because of oscillation. Patients with stroke and positive RLS findings on transesophageal echocardiography underwent a simultaneous extracranial and transcranial sonographic examination of the proximal common carotid artery (CCA) and middle cerebral artery (MCA) on the same side. A Valsalva strain was performed for 10 seconds after intravenous bolus injection of a galactose-based nontranspulmonary contrast agent. The B-mode frame sequences of the transverse plane of the CCA obtained by harmonic ECS and the ce-TCDS recordings of high-intensity transient signals from the MCA were analyzed offline. Results. In all patients with RLS, the shunts could be identified by harmonic ECS. A close correlation could be seen between the count of visualized microbubbles in the CCA and the number of high-intensity transient signals detected on ce-TCDS in the ipsilateral MCA. Conclusions. The results of this study indicate that contrast-enhanced ultrasound harmonic imaging of the CCA using a Valsalva strain might be an optional screening tool for detection of cardiac RLS in patients with insufficient acoustic bone windows.
引用
收藏
页码:1071 / 1076
页数:6
相关论文
共 25 条
[1]  
Bauer J, 1999, VERHALTENSTHERAPIE, V9, P3
[2]   IMPROVED SENSITIVITY OF COLOR DOPPLER BY SH-U-454 [J].
BECHER, H ;
SCHLIEF, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05) :374-377
[3]  
Burns PN, 1997, J NEUROIMAGING, V7, pS2
[4]   ATRIAL SEPTAL ANEURYSM AND PATENT FORAMEN OVALE AS RISK-FACTORS FOR CRYPTOGENIC STROKE IN PATIENTS LESS-THAN 55 YEARS OF AGE - A STUDY USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CABANES, L ;
MAS, JL ;
COHEN, A ;
AMARENCO, P ;
CABANES, PA ;
OUBARY, P ;
CHEDRU, F ;
GUERIN, F ;
BOUSSER, MG ;
DERECONDO, J .
STROKE, 1993, 24 (12) :1865-1873
[5]   A PROSPECTIVE-STUDY OF CEREBRAL-ISCHEMIA IN THE YOUNG - ANALYSIS OF PATHOGENIC DETERMINANTS [J].
CAROLEI, A ;
MARINI, C ;
FERRANTI, E ;
FRONTONI, M ;
PRENCIPE, M ;
FIESCHI, C ;
TOTARO, R ;
LANDI, G ;
BINDA, A ;
DEZANCHE, L ;
PARMA, M ;
SCODITTI, U ;
ZANETTE, EM ;
INZITARI, D ;
NENCINI, P ;
GANDOLFO, C ;
MORETTI, C ;
FINOCCHI, C ;
LOEB, CW .
STROKE, 1993, 24 (03) :362-367
[6]   TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS [J].
CHIMOWITZ, MI ;
NEMEC, JJ ;
MARWICK, TH ;
LORIG, RJ ;
FURLAN, AJ ;
SALCEDO, EE .
NEUROLOGY, 1991, 41 (12) :1902-1904
[7]   PATENT FORAMEN OVALE AS A RISK FACTOR FOR CRYPTOGENIC STROKE [J].
DITULLIO, M ;
SACCO, RL ;
GOPAL, A ;
MOHR, JP ;
HOMMA, S .
ANNALS OF INTERNAL MEDICINE, 1992, 117 (06) :461-465
[8]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts - Comparison of different procedures and different contrast agents [J].
Droste, DW ;
Kriete, JU ;
Stypmann, J ;
Castrucci, M ;
Wichter, T ;
Tietje, R ;
Weltermann, B ;
Young, P ;
Ringelstein, EB .
STROKE, 1999, 30 (09) :1827-1832
[9]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers [J].
Droste, DW ;
Silling, K ;
Stypmann, J ;
Grude, M ;
Kemény, V ;
Wichter, T ;
Kühne, K ;
Ringelstein, EB .
STROKE, 2000, 31 (07) :1640-1645
[10]   THE INCIDENCE OF PATENT FORAMEN OVALE IN 1,000 CONSECUTIVE PATIENTS - A CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY STUDY [J].
FISHER, DC ;
FISHER, EA ;
BUDD, JH ;
ROSEN, SE ;
GOLDMAN, ME .
CHEST, 1995, 107 (06) :1504-1509