Determination of bezafibrate and ciprofibrate in pharmaceutical formulations by densitometric and videodensito metric TLC

被引:10
作者
Misztal, G [1 ]
Korrista, L [1 ]
机构
[1] Med Univ, Dept Med Chem, PL-20093 Lublin, Poland
关键词
normal phase TLC; densitometry; videodensitometry; videoscanning; bezaflbrate; ciprofibrate;
D O I
10.1556/JPC.18.2005.3.3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New simple TLC methods with densitometry and videoscanning have been developed for the quantitation of bezafibrate in Bezamidin tablets and ciprofibrate in Lipanor capsules. Analysis was performed on HPTLC Dint F-254 plates with hexane-tetrahydrofu ran, 8 + 2, as mobile phase. Detection was performed by densitometry at lambda = 227 nm and videoscanning at A = 254 nm. Calibration plots were constructed in the range 5-30 mu g per spot for both drugs. The calibration data were tested using several regression models and the optimum models were selected (quadratic for videoscanning and nonlinear y = ax(m) + b for densitometry; R-2 was always > 0.995). The active substances were extracted from tablets with methanol. The linearity of the method was tested by spotting different amounts of extracted solution (15-30 mg). The recovery function was always sufficiently linear, with an insignificant intercept and slope very close to unity. Accuracy was tested by quantitating three fortified samples (50, 100, and 150%); this resulted in homogeneous results without significant differences. Recovery measured by use of densitometry was 100.3% (RSD 7.84%) for bezalibrate and 98.01% (RSD 6.12%) for ciprofibrate. Videodensitometry resulted in recovery of 96.16% (RSD 9.8%) and 97.8% (RSD 11.2%), respectively. The F-Snedecor test and t-test for two means showed there was no significant difference between the precision and accuracy of the methods.
引用
收藏
页码:188 / 193
页数:6
相关论文
共 6 条
[1]   Lack-of-fit testing of ion chromatographic calibration curves with inexact replicates [J].
Coleman, DE ;
Vanatta, LE .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :43-51
[2]   Comparison of linear and non-linear equations for univariate calibration [J].
Kirkup, L ;
Mulholland, M .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :1-11
[3]   The retention behavior in normal-phase chromatographic systems of some fibrate-type antihyperlipidemic drugs [J].
Misztal, G ;
Komsta, L .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2003, 16 (05) :351-358
[4]  
*R DEV COR TEAM R, 2004, LANG ENV STAT COMP
[5]   Proposals for error-reduction in planar chromatography [J].
Spangenberg, B ;
Klein, KF ;
Mannhardt, J .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2002, 15 (03) :204-209
[6]   Linearity of calibration curves: use and misuse of the correlation coefficient [J].
Van Loco, J ;
Elskens, M ;
Croux, C ;
Beernaert, H .
ACCREDITATION AND QUALITY ASSURANCE, 2002, 7 (07) :281-285