Characterization of an abdominal aortic velocity waveform in patients with abdominal aortic aneurysm

被引:38
作者
Fraser, Katharine H. [1 ]
Meagher, Siobhan [1 ]
Blake, James R. [1 ]
Easson, William J. [1 ]
Hoskins, Peter R. [1 ]
机构
[1] Univ Edinburgh, Sch Engn & Elect, Edinburgh, Midlothian, Scotland
基金
英国工程与自然科学研究理事会;
关键词
abdominal aortic aneurysm; aorta; haemodynamics; spectral Doppler; velocity waveform;
D O I
10.1016/j.ultrasmedbio.2007.06.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Haemodynamics studies of abdominal aortic aneurysm require data on the velocity in the normal section of the aorta. Centreline velocity waveforms were measured in abdominal aortic aneurysm patients proximal to the aneurysm using spectral Doppler ultrasound. Characteristic points were automatically found on 21 of the waveforms and their parameters were used to create an archetypal centreline velocity waveform. The maximum velocity was 45 +/- 13 cm s(-1), the minimum velocity was -15 +/- 11 cult s(-1) and the maximum diastolic velocity was 2.7 +/- 4.7 cm s(-1). The velocity wave is suitable for use as an input to in vitro or in silico investigations of abdominal aortic aneurysm haemodynamics.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 38 条
[1]   Steady flow in an aneurysm model: Correlation between fluid dynamics and blood platelet deposition [J].
Bluestein, D ;
Niu, L ;
Schoephoerster, RT ;
Dewanjee, MK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :280-286
[2]   Abdominal aortic hemodynamic conditions in healthy subjects aged 50-70 at rest and during lower limb exercise: in vivo quantification using MR1 [J].
Cheng, CP ;
Herfkens, RJ ;
Taylor, CA .
ATHEROSCLEROSIS, 2003, 168 (02) :323-331
[3]  
Daigle RJ, 1990, J VASC TECHNOL, V14, P206
[4]  
DAWSON TH, 1991, ENG DESIGN CARDIOVAS, P83
[5]   Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm [J].
Di Martino, ES ;
Guadagni, G ;
Fumero, A ;
Ballerini, G ;
Spirito, R ;
Biglioli, P ;
Redaelli, A .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (09) :647-655
[6]   Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions [J].
Egelhoff, CJ ;
Budwig, RS ;
Elger, DF ;
Khraishi, TA ;
Johansen, KH .
JOURNAL OF BIOMECHANICS, 1999, 32 (12) :1319-1329
[8]   Blood flow in abdominal aortic aneurysms: Pulsatile flow hemodynamics [J].
Finol, EA ;
Amon, CH .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05) :474-484
[9]   THE ROLE OF FLUID-MECHANICS IN THE LOCALIZATION AND DETECTION OF ATHEROSCLEROSIS [J].
GIDDENS, DP ;
ZARINS, CK ;
GLAGOV, S .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :588-594
[10]   Risk: factors for rupture of abdominal aortic aneurysm based on three-dimensional study [J].
Hatakeyama, T ;
Shigematsu, H ;
Muto, T .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) :453-461