On-line speciation of uranyl chelates in supercritical CO2 by time-resolved laser-induced fluorescence spectroscopy

被引:17
作者
Addleman, RS
Carrott, M
Wai, CM [1 ]
Carleson, TE
Wenclawiak, BW
机构
[1] Univ Idaho, Dept Chem, Moscow, ID 83844 USA
[2] Univ Idaho, Dept Chem Engn, Moscow, ID 83844 USA
[3] Univ Siegen, Dept Chem, D-57068 Siegen, Germany
关键词
D O I
10.1021/ac001039p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The dynamic emission characteristics of selected uranyl complexes in supercritical (ScF) CO2 have been quantified with time-resolved laser-induced fluorescence (TRLIF). A variety of factors were found to affect the emission from uranyl complexes in ScF including ligand, adduct, pressure, and temperature. TRLIF was shown to allow on-line speciation and quantitative analysis of uranyl complexes with different primary ligands in ScF CO2. The method was applied to real-time analysis of multiligand uranium extractions from aqueous solutions with ScF CO2.