Coronary sinus lead extraction in the era of cardiac resynchronization therapy: Single center experience

被引:31
作者
Kasravi, B
Tobias, S
Barnes, MJ
Messenger, JC
机构
[1] Long Beach Mem Med Ctr, Mem Heart Inst, Mem Cardiol Med Grp, Long Beach, CA 90806 USA
[2] Univ Calif Irvine, Irvine Med Ctr, Orange, CA 92668 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2005年 / 28卷 / 01期
关键词
coronary sinus; lead extraction; resynchronization;
D O I
10.1111/j.1540-8159.2005.09353.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
As the number of coronary sinus (CS) lead implantations for cardiac resynchronization therapy increases so will the need for extraction of these leads. The safety of extraction of leads from the branches of the CS has not been reported. We reviewed our database of patients undergoing pacemaker lead extraction from January 2002 through February 2004 at our institution, Of 149 patients referred for lead extraction, 14 (9%) had a biventricular device. The indications for lead extraction were infection.. lead malfunction, and exit block. The duration of CS lead implants ranged between 2 and 43 months (mean 17 months). All 14 CS leads were removed successfully using nonsurgical lead extraction techniques. Three leads that were in place the longest (greater than or equal to 27 months) were removed via the femoral vein approach due to fibrous attachment of the CS lead body to the other pacemaker leads. The leads were structurally intact and without any significant fibrosis of their tips upon visual inspection. There were no major complications of CS laceration, hypotension, pericardial effusion, or excessive blood loss associated with any of the extraction procedures. CS leads were removed safely, successfully and with relative ease based on our experience in this small cohort of patients.
引用
收藏
页码:51 / 53
页数:3
相关论文
共 8 条
[1]   Clinical study of the laser sheath for lead extraction: The total experience in the United States [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Reiser, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (05) :804-808
[2]   Pacemaker and defibrillator lead extraction [J].
Kutalek, SP .
CURRENT OPINION IN CARDIOLOGY, 2004, 19 (01) :19-22
[3]   Pacing lead adhesions after long-term ventricular pacing via the coronary sinus [J].
Rosenthal, E ;
Cook, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (12) :1846-1848
[4]   CARDIAC-PACEMAKER ELECTRODES - IMPROVED METHODS OF EXTRACTION - WORK-IN-PROGRESS [J].
SMITH, CW ;
MESSENGER, JC ;
SCHANER, SP ;
RENNER, JW .
RADIOLOGY, 1994, 193 (03) :739-742
[5]   Post-mortem changes after lead extraction from the ovine coronary sinus and great cardiac vein [J].
Tacker, WA ;
Vanvleet, JF ;
Schoenlein, WE ;
Janas, W ;
Ayers, GM ;
Byrd, CL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :296-298
[6]  
Tyers GFO, 2003, PACE, V26, P524
[7]   Successful implantation of a coronary sinus lead after stenting of a coronary vein stenosis [J].
Van Gelder, BM ;
Meijer, A ;
Basting, P ;
Hendrix, G ;
Bracke, FA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (09) :1904-1906
[8]   Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial [J].
Wilkoff, BL ;
Byrd, CL ;
Love, CJ ;
Hayes, DL ;
Sellers, TD ;
Schaerf, R ;
Parsonnet, V ;
Epstein, LM ;
Sorrentino, RA ;
Reiser, C .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1671-1676