13C-octanoic acid breath test (OBT) with a new test meal (EXPIROGer®): Toward standardization for testing gastric emptying of solids

被引:37
作者
Perri, Francesco [1 ]
Bellini, Massimo [2 ]
Portincasa, Piero [3 ]
Parodi, Andrea [4 ]
Bonazzi, Patrizia [5 ]
Marzio, Leonardo [6 ]
Galeazzi, Francesca [7 ]
Usai, Paolo [8 ]
Citrino, Attilio [9 ]
Usai-Satta, Paolo [10 ]
机构
[1] Madonna Soccorso Hosp, Div Gastroenterol & Digest Endoscopy, I-63039 San Benedetto Tronto, Ap, Italy
[2] Univ Pisa, Dept Gastroenterol, Gastroenterol Unit, I-56100 Pisa, Italy
[3] Univ Med Sch, Dept Internal Med & Publ Med, Bari, Italy
[4] Univ Genoa, Dept Internal Med, Gastroenterol Unit, I-16126 Genoa, Italy
[5] Politech Univ Marche, Dept Gastroenterol, Ancona, Italy
[6] Univ G dAnnunzio, Sch Gastroenterol GDAnnunzio, Chieti, Italy
[7] Univ Padua, Dept Surg & Gastroenterol Sci, Gastroenterol Sect, I-35100 Padua, Italy
[8] Univ Cagliari, Gastroenterol Unit, Monserrato, Ca, Italy
[9] SOFAR Diagnost Div, Milan, Italy
[10] Brotzu Hosp, Gastroenterol Unit, Cagliari, Italy
关键词
Dyspepsia; Gastric emptying; Motility disorders; Octanoic acid breath test; Stable isotope; MUFFIN MEAL; SCINTIGRAPHY; SYMPTOMS; DISEASE;
D O I
10.1016/j.dld.2010.01.001
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Standardization of the C-13-octanoic acid breath test is still lacking. Aim: To evaluate the accuracy of the C-13-octanoic acid breath test using a new standardized ready-to-eat, gluten-, glucose-, and lactose-free muffin. Methods: Healthy subjects were recruited and sorted by sex and age. Patients with diabetic gastroparesis and untreated celiac disease with known gastric motility disorders were also tested with the new labelled muffin. Expired breath (CO2)-C-13 was analysed and t(1/2) was calculated. Results: Overall, 131 healthy subjects were enrolled. The reference range of t(1/2) was 88 +/- 29 min with the value of 146 min as the upper limit of normal range. No significant difference in t(1/2) was found among subjects sorted by sex or age. The within-subject variability of t(1/2) was 17%. Mean (+/- standard deviation) t(1/2) values were 179 +/- 50 min in patients with diabetic gastroparesis (n = 8) and 151 +/- 20 min in those with untreated celiac disease (n = 11) (p <= 0.001 vs controls). Conclusions: A new standardized test meal simplifies the execution of the C-13-octanoic acid breath test, is not influenced by sex or age, has low intra-individual variability, is palatable, does not cause side effects, and is able to evaluate gastric emptying in both patients and healthy controls. Moreover, it can be used in subjects with lactose intolerance, diabetes, and celiac disease. (C) 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 50 条
  • [41] Gastric Emptying of Solids and Semi-solids in Morbidly Obese and Non-obese Subjects: An Assessment Using the 13C-Octanoic Acid and 13C-Acetic Acid Breath Tests
    Aloísio Cardoso-Júnior
    Luiz Gonzaga Vaz Coelho
    Paulo Roberto Savassi-Rocha
    Maria Cristina Vignolo
    Marcelo Militão Abrantes
    Aline Miranda de Almeida
    Emanuela Eudes Dias
    Gerival Vieira Júnior
    Mariana Moreira de Castro
    Yara Vieira Lemos
    Obesity Surgery, 2007, 17 : 236 - 241
  • [42] Validity of 13C octanoic acid breath test for measurement of solid meat gastric emptying time in children
    Eradi, B.
    Wright, J.
    Gibbons, Nicola J.
    Blackshaw, P. Elaine
    Perkins, Alan C.
    Wakefield, Jennifer
    Sithole, J.
    Singh, Shailinder Jit
    JOURNAL OF PEDIATRIC SURGERY, 2006, 41 (12) : 2062 - 2065
  • [43] Procedures in the 13C octanoic acid breath test for measurement of gastric emptying: analysis using Bland-Altman methods
    Clegg, Miriam E.
    Shafat, Amir
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2010, 45 (7-8) : 852 - 861
  • [44] Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
    Creedon, Christopher T.
    Verhulst, Pieter-Jan
    Choi, Kyoung M.
    Mason, Jessica E.
    Linden, David R.
    Szurszewski, Joseph H.
    Gibbons, Simon J.
    Farrugia, Gianrico
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (73):
  • [45] Reproducibility and reliability of the 13C-acetate breath test to measure gastric emptying of liquid meal in infants
    Barbosa, L
    Vera, H
    Moran, S
    Del Prado, M
    López-Alarcón, M
    NUTRITION, 2005, 21 (03) : 289 - 294
  • [46] Measurement of Gastric Emptying Using a 13 C-octanoic Acid Breath Test with Wagner-Nelson Analysis and Scintigraphy in Type 2 Diabetes
    Trahair, Laurence G.
    Nauck, Michael A.
    Wu, Tongzhi
    Stevens, Julie E.
    Buttfield, Madeline D.
    Hatzinikolas, Seva
    Pham, Hung
    Meier, Juris J.
    Rayner, Christopher K.
    Horowitz, Michael
    Jones, Karen L.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2022, 130 (11) : 751 - 757
  • [47] Analysis and Optimization of the 13C Octanoic Acid Breath Test
    Bevilacqua, Vitoantonio
    Riezzo, Marco
    Brunetti, Antonio
    Russo, Francesco
    D'Attoma, Benedetta
    Riezzo, Giuseppe
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 4528 - 4533
  • [48] COMBINED CARBON-13-GLYCINE CARBON-14-OCTANOIC ACID BREATH TEST TO MONITOR GASTRIC-EMPTYING RATES OF LIQUIDS AND SOLIDS
    MAES, BD
    GHOOS, YF
    GEYPENS, BJ
    MYS, G
    HIELE, MI
    RUTGEERTS, PJ
    VANTRAPPEN, G
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : 824 - 831
  • [49] Significance of diagnostic parameters in [13C]octanoic acid gastric emptying breath tests
    Schommartz, B
    Ziegler, D
    Schadewaldt, P
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 1997, 33 (1-2) : 135 - 143
  • [50] [C-13]Octanoic acid breath test for non-invasive assessment of gastric emptying in diabetic patients: Validation and relationship to gastric symptoms and cardiovascular autonomic function
    Ziegler, D
    Schadewaldt, P
    Mirza, AP
    Piolot, R
    Schommartz, B
    Reinhardt, M
    Vosberg, H
    Brosicke, H
    Gries, FA
    DIABETOLOGIA, 1996, 39 (07) : 823 - 830