13C-octanoic acid breath test (OBT) with a new test meal (EXPIROGer®): Toward standardization for testing gastric emptying of solids

被引:37
作者
Perri, Francesco [1 ]
Bellini, Massimo [2 ]
Portincasa, Piero [3 ]
Parodi, Andrea [4 ]
Bonazzi, Patrizia [5 ]
Marzio, Leonardo [6 ]
Galeazzi, Francesca [7 ]
Usai, Paolo [8 ]
Citrino, Attilio [9 ]
Usai-Satta, Paolo [10 ]
机构
[1] Madonna Soccorso Hosp, Div Gastroenterol & Digest Endoscopy, I-63039 San Benedetto Tronto, Ap, Italy
[2] Univ Pisa, Dept Gastroenterol, Gastroenterol Unit, I-56100 Pisa, Italy
[3] Univ Med Sch, Dept Internal Med & Publ Med, Bari, Italy
[4] Univ Genoa, Dept Internal Med, Gastroenterol Unit, I-16126 Genoa, Italy
[5] Politech Univ Marche, Dept Gastroenterol, Ancona, Italy
[6] Univ G dAnnunzio, Sch Gastroenterol GDAnnunzio, Chieti, Italy
[7] Univ Padua, Dept Surg & Gastroenterol Sci, Gastroenterol Sect, I-35100 Padua, Italy
[8] Univ Cagliari, Gastroenterol Unit, Monserrato, Ca, Italy
[9] SOFAR Diagnost Div, Milan, Italy
[10] Brotzu Hosp, Gastroenterol Unit, Cagliari, Italy
关键词
Dyspepsia; Gastric emptying; Motility disorders; Octanoic acid breath test; Stable isotope; MUFFIN MEAL; SCINTIGRAPHY; SYMPTOMS; DISEASE;
D O I
10.1016/j.dld.2010.01.001
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Standardization of the C-13-octanoic acid breath test is still lacking. Aim: To evaluate the accuracy of the C-13-octanoic acid breath test using a new standardized ready-to-eat, gluten-, glucose-, and lactose-free muffin. Methods: Healthy subjects were recruited and sorted by sex and age. Patients with diabetic gastroparesis and untreated celiac disease with known gastric motility disorders were also tested with the new labelled muffin. Expired breath (CO2)-C-13 was analysed and t(1/2) was calculated. Results: Overall, 131 healthy subjects were enrolled. The reference range of t(1/2) was 88 +/- 29 min with the value of 146 min as the upper limit of normal range. No significant difference in t(1/2) was found among subjects sorted by sex or age. The within-subject variability of t(1/2) was 17%. Mean (+/- standard deviation) t(1/2) values were 179 +/- 50 min in patients with diabetic gastroparesis (n = 8) and 151 +/- 20 min in those with untreated celiac disease (n = 11) (p <= 0.001 vs controls). Conclusions: A new standardized test meal simplifies the execution of the C-13-octanoic acid breath test, is not influenced by sex or age, has low intra-individual variability, is palatable, does not cause side effects, and is able to evaluate gastric emptying in both patients and healthy controls. Moreover, it can be used in subjects with lactose intolerance, diabetes, and celiac disease. (C) 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 50 条
  • [31] Gastric emptying in formula-fed and breast-fed infants measured with the 13C-octanoic acid breath test
    Van Den Driessche, M
    Peeters, K
    Marien, P
    Ghoos, Y
    Devlieger, H
    Veereman-Wauters, G
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1999, 29 (01) : 46 - 51
  • [32] Assessment of the rate of solid-phase gastric emptying in ponies by means of the 13C-octanoic acid breath test:: a preliminary study
    Wyse, CA
    Murphy, DM
    Preston, T
    Morrison, DJ
    Love, S
    EQUINE VETERINARY JOURNAL, 2001, 33 (02) : 197 - 203
  • [33] Effects of Helicobacter pylori eradication therapy on gastric emptying measured using the 13C-octanoic acid breath test and the acetaminophen method
    Kachi, Masaaki
    Shirasaka, Daisuke
    Aoyama, Nobuo
    Ebara, Shigeyuki
    Miki, Ikuya
    Morita, Yoshinori
    Tamura, Takao
    Kasuga, Masato
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2006, 21 (05) : 824 - 830
  • [34] [ASTERISK-C]OCTANOIC ACID BREATH TEST TO MEASURE GASTRIC-EMPTYING RATE OF SOLIDS
    MAES, BD
    GHOOS, YF
    RUTGEERTS, PJ
    HIELE, MI
    GEYPENS, B
    VANTRAPPEN, G
    DIGESTIVE DISEASES AND SCIENCES, 1994, 39 (12) : S104 - S106
  • [35] The [13C]octanoic acid breath test for gastric emptying quantification: A focus on nutrition and modeling
    von Gerichten, Johanna
    Elnesr, Marwan H.
    Prollins, Joe E.
    De Mel, Ishanki A.
    Flanagan, Alan
    Johnston, Jonathan D.
    Fielding, Barbara A.
    Short, Michael
    LIPIDS, 2022, 57 (4-5) : 205 - 219
  • [36] Effects of mineral-water supplementation on gastric emptying of solids in patients with functional dyspepsia assessed with the 13C-octanoic-acid breath test
    Anti, M
    Lippi, ME
    Santarelli, L
    Gabrielli, M
    Gasbarrini, A
    Gasbarrini, G
    HEPATO-GASTROENTEROLOGY, 2004, 51 (60) : 1856 - 1859
  • [37] 13C-acetic acid is more sensitive than 13C-octanoic acid for evaluating gastric emptying of liquid enteral nutrient formula by breath test in conscious rats
    Uchida, Masayuki
    Shimizu, Kimiko
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2007, 30 (03) : 487 - 489
  • [38] The C-13-octanoic acid breath test: A noninvasive technique to assess gastric emptying in preterm infants
    VeeremanWauters, G
    Ghoos, Y
    vanderSchoor, S
    Maes, B
    Hebbalkar, N
    Devlieger, H
    Eggermont, E
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1996, 23 (02) : 111 - 117
  • [39] Gastric emptying in patients with Type 2 diabetes mellitus and diabetes associated with mitochondrial DNA 3243 mutation using 13C-octanoic acid breath test
    Nohara, Sakae
    Iwase, Masanori
    Imoto, Hirofumi
    Sasaki, Nobuhiro
    Nakamura, Udai
    Uchizono, Yuji
    Abe, Saori
    Doi, Yasufumi
    Iida, Mitsuo
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2006, 20 (05) : 295 - 301
  • [40] Gastric Emptying of Solids and Semi-solids in Morbidly Obese and Non-obese Subjects: An Assessment Using the 13C-Octanoic Acid and 13C-Acetic Acid Breath Tests
    Aloísio Cardoso-Júnior
    Luiz Gonzaga Vaz Coelho
    Paulo Roberto Savassi-Rocha
    Maria Cristina Vignolo
    Marcelo Militão Abrantes
    Aline Miranda de Almeida
    Emanuela Eudes Dias
    Gerival Vieira Júnior
    Mariana Moreira de Castro
    Yara Vieira Lemos
    Obesity Surgery, 2007, 17 : 236 - 241