13C-octanoic acid breath test (OBT) with a new test meal (EXPIROGer®): Toward standardization for testing gastric emptying of solids

被引:37
|
作者
Perri, Francesco [1 ]
Bellini, Massimo [2 ]
Portincasa, Piero [3 ]
Parodi, Andrea [4 ]
Bonazzi, Patrizia [5 ]
Marzio, Leonardo [6 ]
Galeazzi, Francesca [7 ]
Usai, Paolo [8 ]
Citrino, Attilio [9 ]
Usai-Satta, Paolo [10 ]
机构
[1] Madonna Soccorso Hosp, Div Gastroenterol & Digest Endoscopy, I-63039 San Benedetto Tronto, Ap, Italy
[2] Univ Pisa, Dept Gastroenterol, Gastroenterol Unit, I-56100 Pisa, Italy
[3] Univ Med Sch, Dept Internal Med & Publ Med, Bari, Italy
[4] Univ Genoa, Dept Internal Med, Gastroenterol Unit, I-16126 Genoa, Italy
[5] Politech Univ Marche, Dept Gastroenterol, Ancona, Italy
[6] Univ G dAnnunzio, Sch Gastroenterol GDAnnunzio, Chieti, Italy
[7] Univ Padua, Dept Surg & Gastroenterol Sci, Gastroenterol Sect, I-35100 Padua, Italy
[8] Univ Cagliari, Gastroenterol Unit, Monserrato, Ca, Italy
[9] SOFAR Diagnost Div, Milan, Italy
[10] Brotzu Hosp, Gastroenterol Unit, Cagliari, Italy
关键词
Dyspepsia; Gastric emptying; Motility disorders; Octanoic acid breath test; Stable isotope; MUFFIN MEAL; SCINTIGRAPHY; SYMPTOMS; DISEASE;
D O I
10.1016/j.dld.2010.01.001
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Standardization of the C-13-octanoic acid breath test is still lacking. Aim: To evaluate the accuracy of the C-13-octanoic acid breath test using a new standardized ready-to-eat, gluten-, glucose-, and lactose-free muffin. Methods: Healthy subjects were recruited and sorted by sex and age. Patients with diabetic gastroparesis and untreated celiac disease with known gastric motility disorders were also tested with the new labelled muffin. Expired breath (CO2)-C-13 was analysed and t(1/2) was calculated. Results: Overall, 131 healthy subjects were enrolled. The reference range of t(1/2) was 88 +/- 29 min with the value of 146 min as the upper limit of normal range. No significant difference in t(1/2) was found among subjects sorted by sex or age. The within-subject variability of t(1/2) was 17%. Mean (+/- standard deviation) t(1/2) values were 179 +/- 50 min in patients with diabetic gastroparesis (n = 8) and 151 +/- 20 min in those with untreated celiac disease (n = 11) (p <= 0.001 vs controls). Conclusions: A new standardized test meal simplifies the execution of the C-13-octanoic acid breath test, is not influenced by sex or age, has low intra-individual variability, is palatable, does not cause side effects, and is able to evaluate gastric emptying in both patients and healthy controls. Moreover, it can be used in subjects with lactose intolerance, diabetes, and celiac disease. (C) 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 50 条
  • [21] Effect of body size on gastric emptying using the 13C-octanoic acid breath test
    Yam, PS
    McLellan, J
    Wyse, C
    Reid, SWJ
    Cooper, J
    Preston, T
    JOURNAL OF SMALL ANIMAL PRACTICE, 2004, 45 (08) : 386 - 389
  • [22] Bayesian Hierarchical Methods to Interpret the 13C-Octanoic Acid Breath Test for Gastric Emptying
    Bluck, Leslie J. C.
    Jackson, Sarah J.
    Vlasakakis, Georgios
    Mander, Adrian
    DIGESTION, 2011, 83 (1-2) : 96 - 107
  • [23] The "stepped" assessment of solid gastric emptying with 13C-octanoic acid breath test.
    Aoki, S
    Haruma, K
    Hata, J
    Matsumura, S
    Futagami, K
    Yoshida, S
    Kusunoki, H
    Kitadai, Y
    Tanaka, S
    Yoshihara, M
    Sumii, K
    Kajiyama, G
    GASTROENTEROLOGY, 2000, 118 (04) : A143 - A143
  • [24] How accurate is the measurement of gastric emptying of solids by 13C-octanoic acid breath test in symptomatic diabetic patients?
    Lee, JS
    Choi, MG
    Burton, DD
    Nair, KS
    Verlinden, M
    Olson, CA
    Camilleri, M
    GASTROENTEROLOGY, 1998, 114 (04) : A786 - A786
  • [25] Development of gastric emptying in premature infants:: Use of the 13C-octanoic acid breath test
    Pozler, O
    Neumann, D
    Vorisek, V
    Bukac, J
    Bures, J
    Kokstein, Z
    NUTRITION, 2003, 19 (7-8) : 593 - 596
  • [26] Validation of the 13C-octanoic acid breath test for measurement of equine gastric emptying rate of solids using radioscintigraphy
    Sutton, DGM
    Bahr, A
    Preston, T
    Christley, RM
    Love, S
    Roussel, AJ
    EQUINE VETERINARY JOURNAL, 2003, 35 (01) : 27 - 33
  • [27] The 13C-octanoic acid breath test:: validation of a new noninvasive method of measuring gastric emptying in rats
    Schoonjans, R
    Van Vlem, B
    Van Heddeghem, N
    Vandamme, W
    Vanholder, R
    Lameire, N
    Lefebvre, R
    De Vos, M
    NEUROGASTROENTEROLOGY AND MOTILITY, 2002, 14 (03): : 287 - 293
  • [28] The evaluation of solid gastric emptying with 13C-octanoic acid breath test -: Comparison with ultrasonography-.
    Kusunoki, H
    Haruma, K
    Aoki, S
    Hata, J
    Matsumura, S
    Yoshida, S
    Futagami, K
    Kitadai, Y
    Tanaka, S
    Yoshihara, M
    Sumii, K
    Kajiyama, G
    GASTROENTEROLOGY, 2000, 118 (04) : A1183 - A1183
  • [29] Comparison of 13C-octanoic breath test and scintigraphy for the assessment of gastric emptying.
    Holtmann, G
    Neufang-Hueber, J
    Haag, S
    Kaune, A
    Eising, EG
    Talley, NJ
    Gerken, G
    GASTROENTEROLOGY, 1999, 116 (04) : A1008 - A1008
  • [30] Reproducibility of the 13C-octanoic acid breath test for assessment of gastric emptying in healthy preterm infants
    Barnett, C
    Snel, A
    Omari, T
    Davidson, G
    Haslam, R
    Butler, R
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1999, 29 (01): : 26 - 30