Flexible polyimide-based force sensor

被引:98
作者
Dobrzynska, Jagoda A. [1 ]
Gijs, Martin A. M. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Microsyst, CH-1015 Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
Force sensor; Capacitive sensor; Flexible sensor; Polyimide; Pattern transfer; Capacitor model; POLYMER TACTILE SENSOR; CLINICAL-ASSESSMENT; SHEAR; FABRICATION; TRANSDUCER; PRESSURE; STRESS; RELEASE; DEVICE; ARRAY;
D O I
10.1016/j.sna.2011.11.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have realized a flexible force sensor, composed of four redundant capacitors, the operation of which is based on the measurement of at load-induced capacitance change. We use polyimide both as flexible substrate and as elastic dielectric between two levels of finger-shaped aluminum electrodes. In particular we have developed a technology for realization of two-level polyimide microstructures with gentle slopes to facilitate subsequent metallization processes. Thereby, we could improve step coverage and electrical contacting between the two metallization levels, as well as the mechanical stability of the sensor. The smooth polyimide slopes were obtained by combining lithographic resist-reflow techniques with dry etching procedures. We have analytically modeled the sensor's capacitance and its force sensitivity. We have electrically characterized the capacitors using an impedance analyzer and obtained capacitances in the range of 130 pF and a typical force sensitivity of 0.5-1 fF/N, in excellent agreement with our model. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 65 条
[41]   Partial release and detachment of microfabricated metal and polymer structures by anodic metal dissolution [J].
Metz, S ;
Bertsch, A ;
Renaud, P .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (02) :383-391
[42]  
Microsystems HD, 2011, LIQ POL PBO PREC
[43]   CAPACITIVE TRANSDUCER FOR CONTINUOUS MEASUREMENT OF VERTICAL FOOT FORCE [J].
MIYAZAKI, S ;
ISHIDA, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :309-316
[44]   FOOT-FORCE MEASURING DEVICE FOR CLINICAL-ASSESSMENT OF PATHOLOGICAL GAIT [J].
MIYAZAKI, S ;
IWAKURA, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (04) :429-436
[45]   Miniaturized flexible temperature sensor [J].
Moser, Yves ;
Gijs, Maitin A. M. .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (06) :1349-1354
[46]   Novel MEMS stiffness sensor for force and elasticity measurements [J].
Peng, P. ;
Sezen, A. S. ;
Rajamani, R. ;
Erdman, A. G. .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 158 (01) :10-17
[47]   Aluminum nitride based 3D, piezoelectric, tactile sensor [J].
Polster, Tobias ;
Hoffmann, Martin .
PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01) :144-147
[48]   CAPACITIVE SENSORS - WHEN AND HOW TO USE THEM [J].
PUERS, R .
SENSORS AND ACTUATORS A-PHYSICAL, 1993, 37-8 :93-105
[49]   MINIATURE LOAD CELLS FOR THE MEASUREMENT OF FOOT-GROUND REACTION FORCES AND CENTER OF FOOT PRESSURE DURING GAIT [J].
RANU, HS .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (02) :175-177
[50]   Design, development, and characteristics of an in-shoe triaxial pressure measurement transducer utilizing a single element of piezoelectric copolymer film [J].
Razian, MA ;
Pepper, MG .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (03) :288-293