An image-based rat model for Monte Carlo organ dose calculations

被引:29
|
作者
Wu, Li [1 ]
Zhang, Guozhi [1 ]
Luo, Qingming [1 ]
Liu, Qian [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
voxel; organ dose; Monte Carlo;
D O I
10.1118/1.2952647
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An anatomically realistic rat model was developed from color images of successive cryosections of a mature Sprague-Dawley rat. Images were obtained, by digital scanning, of 9475 slices with thickness of 0.02 mm. A total of 13 major organs and tissues were selected, and models of these organs and tissues constructed from the images were used for calculations of absorbed dose from external photon sources. A detailed set of conversion coefficients from kerma free-in-air to organ absorbed dose have been calculated for external monoenergetic photon beams with energies ranging from 10 keV to 10 MeV under five idealized irradiation conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic) using the Monte Carlo code MCNPX. Dose results are presented in form of tables as supplemental data for practical use and comparison. The influence of anatomical characteristics, including organ volume, shape, location, and orientation, on dose distributions were evaluated. It would also be possible to make internal dose assessments using the computational rat model. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3759 / 3764
页数:6
相关论文
共 50 条
  • [21] Dose calculations with the BEAM Monte Carlo code at extended SSD's
    Stathakis, S
    Kappas, C
    Papanikolaou, N
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1679 - 1680
  • [22] Point flux PL-estimators for Monte Carlo dose calculations
    Donskoy, EN
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3203 - 3205
  • [23] ATOM-MIRD Hybrid Voxel Model for Monte Carlo Calculations of Organ Doses: A Complement to a Physical Phantom
    Cho, Sungkoo
    Choi, Sang Hyoun
    Yi, Chul-Young
    Kim, Chan Hyeong
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 306 - 308
  • [24] VIP-man: An image-based whole-body adult male model constructed from color photographs of the visible human project for multi-particle Monte Carlo calculations
    Xu, XG
    Chao, TC
    Bozkurt, A
    HEALTH PHYSICS, 2000, 78 (05): : 476 - 486
  • [25] Monte Carlo based operational and shutdown dose rate calculations of HT-7U tokamak
    Chen, YX
    Wu, YC
    Huang, QY
    FUSION ENGINEERING AND DESIGN, 2004, 70 (02) : 155 - 162
  • [26] Sub-second high dose rate brachytherapy Monte Carlo dose calculations with bGPUMCD
    Hissoiny, Sami
    D'Amours, Michel
    Ozell, Benoit
    Despres, Philippe
    Beaulieu, Luc
    MEDICAL PHYSICS, 2012, 39 (07) : 4559 - 4567
  • [27] Measurement of organ dose in chest CT examination using Monte Carlo simulation
    Harki, E. M. T.
    Al-Kinani, A. T.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2007, 4 (04): : 205 - 209
  • [28] Monte Carlo calculations of radiotherapy dose distributions within and around orthopaedic implants
    Katsifis, Georgio Andrew
    McKenzie, David R.
    Suchowerska, Natalka
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 123 - 130
  • [29] MONTE CARLO CALCULATIONS OF NEUTRON DOSE CONVERSION COEFFICIENTS FOR REFERENCE KOREAN MALE
    Kim, Chan Hyeong
    Jeong, Jong Hwi
    Cho, Sungkoo
    Choi, Sang Hyoun
    Chung, Min Suk
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 345 - 348
  • [30] Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
    Bush, K.
    Gagne, I. M.
    Zavgorodni, S.
    Ansbacher, W.
    Beckham, W.
    MEDICAL PHYSICS, 2011, 38 (04) : 2208 - 2221