An image-based rat model for Monte Carlo organ dose calculations

被引:29
|
作者
Wu, Li [1 ]
Zhang, Guozhi [1 ]
Luo, Qingming [1 ]
Liu, Qian [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
voxel; organ dose; Monte Carlo;
D O I
10.1118/1.2952647
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An anatomically realistic rat model was developed from color images of successive cryosections of a mature Sprague-Dawley rat. Images were obtained, by digital scanning, of 9475 slices with thickness of 0.02 mm. A total of 13 major organs and tissues were selected, and models of these organs and tissues constructed from the images were used for calculations of absorbed dose from external photon sources. A detailed set of conversion coefficients from kerma free-in-air to organ absorbed dose have been calculated for external monoenergetic photon beams with energies ranging from 10 keV to 10 MeV under five idealized irradiation conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic) using the Monte Carlo code MCNPX. Dose results are presented in form of tables as supplemental data for practical use and comparison. The influence of anatomical characteristics, including organ volume, shape, location, and orientation, on dose distributions were evaluated. It would also be possible to make internal dose assessments using the computational rat model. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3759 / 3764
页数:6
相关论文
共 50 条
  • [1] Effect of CT image-based voxel size on Monte Carlo dose calculation
    Wu Ai-dong
    Wu Yi-can
    Tao Sheng-xiang
    Zhang Jian-hui
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6449 - 6451
  • [2] An anatomically realistic lung model for Monte Carlo-based dose calculations
    Liang, Liang
    Larsen, Edward W.
    Chetty, Indrin J.
    MEDICAL PHYSICS, 2007, 34 (03) : 1013 - 1025
  • [3] A comparison of Monte Carlo and model-based dose calculations in radiotherapy using MCNPTV
    Wyatt, Mark S.
    Miller, Laurence F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02): : 1013 - 1016
  • [4] Evaluating Effective Dose: A Comparison of Methods Based on Organ Dose Calculations versus Dose-Length Product and Monte Carlo Simulation
    Abuelhia, Elfatih
    Tajaldeen, Abdulrahman
    Alghamdi, Ali
    Mabrouk, Osama
    Aluraik, Wejdan
    Msmar, Amir
    Elsadig, Muawia
    Osman, Entisar
    Al-Othman, Abdullah
    Alghamdi, Salem
    Albadri, Mesbah
    Aljondi, Rowa
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [5] The development and application of the Visible Chinese Human model for Monte Carlo dose calculations
    Zhang, Guozhi
    Luo, Qingming
    Zeng, Shaoqun
    Liu, Qian
    HEALTH PHYSICS, 2008, 94 (02): : 118 - 125
  • [6] A photon source model based on particle transport in a parameterized accelerator structure for Monte Carlo dose calculations
    Ishizawa, Yoshiki
    Dobashi, Suguru
    Kadoya, Noriyuki
    Ito, Kengo
    Chiba, Takahito
    Takayama, Yoshiki
    Sato, Kiyokazu
    Takeda, Ken
    MEDICAL PHYSICS, 2018, 45 (07) : 2937 - 2946
  • [7] Analysis of Uncertainties in Monte Carlo Simulated Organ Dose for Chest CT
    Muryn, John S.
    Morgan, Ashraf G.
    Segars, W. Paul
    Liptak, Chris L.
    Dong, Frank F.
    Primak, Andrew N.
    Li, Xiang
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [8] Monte Carlo calculations of radiotherapy dose in "homogeneous" anatomy
    Kairn, Tanya
    Livingstone, Alexander G.
    Crowe, Scott B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 156 - 165
  • [9] Organ Dose Calculations Using ICRP Adult Voxel Phantoms and TRIPOLI-4 Monte Carlo Code
    Lee, Yi-Kang
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2020, 6 (04):
  • [10] Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculations
    Jiang, Hongyu
    Seco, Joao
    Paganetti, Harald