ANESTHESIA INFORMATION MANAGEMENT SYSTEMS: A REVIEW OF FUNCTIONALITY AND INSTALLATION CONSIDERATIONS

被引:44
作者
Ehrenfeld, Jesse M. [1 ]
Rehman, Mohamed A. [2 ,3 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[2] Univ Penn, Dept Anesthesiol & Crit Care, Philadelphia, PA 19104 USA
[3] Childrens Hosp Philadelphia, Dept Anesthesiol & Crit Care Med, Philadelphia, PA 19104 USA
关键词
anesthesia; information systems; AIMS; informatics; software; OPERATING-ROOM; DOCUMENTATION; RECORD; CARE; IMPLEMENTATION; SURGERY; QUALITY; EVENTS;
D O I
10.1007/s10877-010-9256-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The functionality and rate of implementation of Anesthesia Information Management Systems (AIMS) has markedly risen over the past decade. These systems have now become much more than the generic automated record keepers, originally proposed and developed in the 1980s. AIMS have now become complex integrated systems, which have been shown to improve patient care and, in some cases, the financial performance of a department. Although the underlying technology has improved greatly over the past 5 years, the process of selecting and completing an AIMS installation still presents a number of challenges, and must be approached carefully in order to maximize the benefits provided by these systems.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 35 条
[1]   EFFECT OF AUTOMATIC RECORD-KEEPING ON VIGILANCE AND RECORD-KEEPING TIME [J].
ALLARD, J ;
DZWONCZYK, R ;
YABLOK, D ;
BLOCK, FE ;
MCDONALD, JS .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (05) :619-626
[2]   Perioperative cardiovascular mortality in noncardiac surgery: Validation of the Lee cardiac risk index [J].
Boersma, E ;
Kertai, MD ;
Schouten, O ;
Bax, JJ ;
Noordzij, P ;
Steyerberg, EW ;
Schinkel, AFL ;
van Santen, M ;
Simoons, ML ;
Thomson, IR ;
Klein, J ;
van Urk, H ;
Poldermans, D .
AMERICAN JOURNAL OF MEDICINE, 2005, 118 (10) :1134-1141
[3]   DIFFERENCES BETWEEN HANDWRITTEN AND AUTOMATIC BLOOD-PRESSURE RECORDS [J].
COOK, RI ;
MCDONALD, JS ;
NUNZIATA, E .
ANESTHESIOLOGY, 1989, 71 (03) :385-390
[4]   The anesthetic record: accuracy and completeness [J].
Devitt, JH ;
Rapanos, T ;
Kurrek, M ;
Cohen, MM ;
Shaw, M .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (02) :122-128
[5]   Use of an automated anesthesia information system to determine reference limits for vital signs during cesarean section [J].
Dexter, F ;
Penning, DH ;
Lubarsky, DA ;
DeLong, E ;
Sanderson, I ;
Gilbert, BC ;
Bell, E ;
Reves, JG .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1998, 14 (7-8) :491-498
[6]  
EDSALL DW, 1991, J CLIN MONITOR, V7, P351, DOI 10.1007/BF01619360
[7]   Right- and left-sided Mallinckrodt double-lumen tubes have identical clinical performance [J].
Ehrenfeld, Jesse M. ;
Walsh, John L. ;
Sandberg, Warren S. .
ANESTHESIA AND ANALGESIA, 2008, 106 (06) :1847-1852
[8]   Anesthesia information management systems: A survey of current implementation policies and practices [J].
Epstein, Richard H. ;
Vigoda, Michael M. ;
Feinstein, David M. .
ANESTHESIA AND ANALGESIA, 2007, 105 (02) :405-411
[9]   Development of a scheduled drug diversion surveillance system based on an analysis of atypical drug transactions [J].
Epstein, Richard H. ;
Gratch, David M. ;
Grunwald, Zvi .
ANESTHESIA AND ANALGESIA, 2007, 105 (04) :1053-1060
[10]   Implications of Event Entry Latency on Anesthesia Information Management Decision Support Systems [J].
Epstein, Richard H. ;
Dexter, Franklin ;
Ehrenfeld, Jesse M. ;
Sandberg, Warren S. .
ANESTHESIA AND ANALGESIA, 2009, 108 (03) :941-947