STABILITY OF SLOT-RECTANGULAR SPOUTED BEDS: EFFECT OF SLOT CONFIGURATION

被引:19
作者
Chen, Z. [1 ]
Lim, C. J. [1 ]
Grace, J. R. [1 ]
机构
[1] Univ British Columbia, Dept Chem & Biol Engn, Vancouver, BC V6T 1Z3, Canada
关键词
slot-rectangular; spouted bed; stability; gas inlet; pressure fluctuations; HYDRODYNAMICS; REGIMES; PARTICLES;
D O I
10.1002/cjce.20511
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experiments were carried out to determine the flow stability of slot-rectangular spouted beds of 300 x 100 mm cross-section with slots of different widths, lengths, and depths. The effects of slot expansion angle and diverging base were also investigated. Dependent variables included the minimum spouting velocity, bed pressure drop and standard deviation of pressure fluctuations. Based on the flow regimes and spout termination mechanisms, instability was found to be mainly due to the interaction of multiple spouts. Criteria were identified relating stable spouting to slot dimensions and particle size. Slots of limited cross-sectional area can provide sustainable and symmetric spouting with little fluctuation, as long as the slot length-to-width ratio and depth are within certain limits, related to those for conventional spouted beds.
引用
收藏
页码:1401 / 1407
页数:7
相关论文
共 25 条
  • [1] Chandnani P.P., 1986, FLUIDIZATION, P233
  • [2] Hydrodynamics of slot-rectangular spouted beds: Effect of slot configuration on the local flow structure
    Chen, Z.
    Lim, C. J.
    Grace, J. R.
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2008, 86 (03) : 598 - 604
  • [3] Chen Z., 2008, THESIS U BRIT COLUMB
  • [4] Hydrodynamics and stability of slot-rectangular spouted beds. Part I: Thin bed
    Dogan, OM
    Freitas, LAP
    Lim, CJ
    Grace, JR
    Luo, B
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 2000, 181 : 225 - 242
  • [5] Hydrodynamic studies in a half slot-rectangular spouted bed column
    Dogan, ÖM
    Uysal, BZ
    Grace, JR
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 2004, 191 (04) : 566 - 579
  • [6] Coating of urea with an aqueous polymeric suspension in a two-dimensional spouted bed
    Donida, MW
    Rocha, SCS
    [J]. DRYING TECHNOLOGY, 2002, 20 (03) : 685 - 704
  • [7] Hydrodynamics and stability of slot-rectangular spouted beds - Part II: Increasing bed thickness
    Freitas, LAP
    Dogan, OM
    Lim, CJ
    Grace, JR
    Luo, B
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 2000, 181 : 243 - 258
  • [8] Freitas LAP, 2004, CAN J CHEM ENG, V82, P60
  • [9] PERMANENT JET FORMATION IN BEDS OF PARTICULATE SOLIDS
    GRACE, JR
    LIM, CJ
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1987, 65 (01) : 160 - 162
  • [10] SPOUTED BED AND SPOUT FLUID BED BEHAVIOR IN A COLUMN OF DIAMETER 0.91-M
    HE, YL
    LIM, CJ
    GRACE, JR
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1992, 70 (05) : 848 - 857