Fluorinated monolithic column for CEC

被引:7
作者
Choodum, Aree [1 ,2 ]
Smith, Norman William [3 ]
Thavarungkul, Panote [2 ,4 ]
Kanatharana, Proespichaya [2 ,5 ]
机构
[1] Prince Songkla Univ, Dept Appl Sci, Fac Sci, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[3] Kings Coll London, Micro Separat Grp, Pharmaceut Sci Res Div, London WC2R 2LS, England
[4] Prince Songkla Univ, Dept Phys, Fac Sci, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Dept Chem, Fac Sci, Hat Yai 90112, Songkhla, Thailand
关键词
Fluorinated monolith; Material technology; Monolithic material; Separate CEC and analytical technique; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY ELECTROCHROMATOGRAPHY; REVERSED-PHASE; STATIONARY-PHASE; METHACRYLATE; SEPARATIONS; RETENTION; SILICA; HPLC;
D O I
10.1002/jssc.201000873
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to overcome the drawbacks associated with particle-based fluorinated stationary phases, a fluorinated cationic monolith was successfully synthesized by the in situ copolymerization of a 45% monomer mixture and 55% porogens with thermal initiation using 0.1% initiator with respect to the monomer mixture. The monomer mixture was composed of perfluorododecyl acrylate (49.75%), ethylene dimethacrylate (49.75%), and 0.5% of the quaternary amine acrylic monomer supporting an anodal electroosmotic flow. A tertiary porogenic solvent system consisting of 40% 1-propanol, 40% 1-octanol, and 20% 1-dodecanol was used. The resulting monolith column showed good characteristics in terms of morphology, permeability (pressure drop was 4.8-25.7 MPa between 5 and 25 mu L/min), and the electroosmotic mobility (3.68 (+/- 0.05) x 10(-4) cm(2) v(-1) s(-1)). The monolith was tested for the separation of four phenolic compounds, three aromatic hydrocarbons, and one fluorine-containing compound. Good efficiencies (up to 135 000 (+/- 4000) plate/m and resolution up to 2.6 (+/- 0.1)) with short analysis time (< 9 min for tau-fluvalinate, <7 min for four phenolic compounds, and <12 min for three aromatic hydrocarbons) and good stability (1.0-1.5% RSD for intraday, 1.2-1.6% RSD for interday, and 3.9-5.0% RSD for column-to-column) were obtained.
引用
收藏
页码:2264 / 2270
页数:7
相关论文
共 21 条
[1]   Capillary electrochromatography with monolithic stationary phases - II. Preparation of cationic stearyl-acrylate monoliths and their electrochromatographic characterization [J].
Bedair, M ;
El Rassi, Z .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1013 (1-2) :35-45
[2]   LIQUID-CHROMATOGRAPHIC SEPARATIONS OF DIHYDROXYBENZENES WITH SILICA, DIAMINE, AND COBALT COMPLEX BONDED PHASE COLUMNS [J].
CHANG, CA ;
TU, CF .
ANALYTICAL CHEMISTRY, 1982, 54 (07) :1179-1182
[3]   Ecstasy Analysis by Monolithic Materials-Capillary Electrochromatography [J].
Choodum, Aree ;
Thavarungkul, Panote ;
Kanatharana, Proespichaya ;
Smith, Norman W. .
ANALYTICAL SCIENCES, 2009, 25 (04) :517-522
[4]   Fritless Xterra Particles Encapsulated Within a Poly(butylmethacrylate) Based Monolith for Use in CEC [J].
Choodum, Aree ;
Thavarungkul, Panote ;
Kanatharana, Proespichaya ;
Smith, Norman William .
CHROMATOGRAPHIA, 2009, 69 (5-6) :481-488
[5]   Development of fluorinated, monolithic columns for improved chromatographic separations of fluorous-tagged analytes [J].
Daley, Adam B. ;
Oleschuk, Richard D. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (05) :772-780
[6]   Preparation of macroporous methacrylate monolithic material with convective flow properties for bioseparation: Investigating the kinetics of pore formation and hydrodynamic performance [J].
Danquah, Michael K. ;
Forde, Gareth M. .
CHEMICAL ENGINEERING JOURNAL, 2008, 140 (1-3) :593-599
[7]   Polyacrylamide-based monolithic capillary column with coating of cellulose tris(3,5-dimethylphenyl-carbamate) for enantiomer separation in capillary electrochromatography [J].
Dong, Xiaoli ;
Wu, Ren'an ;
Dong, Jing ;
Wu, Minghuo ;
Zhu, Yan ;
Zou, Hanfa .
ELECTROPHORESIS, 2008, 29 (04) :919-927
[8]   Practical aspects of using methacrylate-ester-based monolithic columns in capillary electrochromatography [J].
Eeltink, S ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (01) :74-79
[9]   Monolithic columns with mixed modes of reversed-phase and anion-exchange stationary phase for capillary electrochromatography [J].
Fu, HJ ;
Xie, CH ;
Xiao, H ;
Dong, J ;
Hu, JW ;
Zou, HF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :237-244
[10]   Preparation and evaluation of poly (polyethylene glycol methyl ether acrylate-co-polyethylene glycol diacrylate) monolith for protein analysis [J].
Gu, BH ;
Armenta, JM ;
Lee, ML .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :382-391