Development and validation of a fast and sensitive UPLC-MS/MS method for the quantification of six probe metabolites for the in vitro determination of cytochrome P450 activity

被引:42
作者
De Bock, Lies [1 ]
Boussery, Koen [1 ]
Colin, Pieter [1 ]
De Smet, Julie [1 ]
T'Jollyn, Huybrecht [1 ]
Van Bocxlaer, Jan [1 ]
机构
[1] Univ Ghent, Lab Med Biochem & Clin Anal, B-9000 Ghent, Belgium
关键词
Cytochrome P450; Drug metabolism; Human liver microsomes; Ultra high performance liquid chromatography-mass spectrometry; Validation; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; INHIBITION ASSAYS; LC-MS/MS; ENZYMES; STRATEGIES; LIVER; COCKTAIL; P450S;
D O I
10.1016/j.talanta.2011.11.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast and sensitive UPLC-MS/MS method was developed and validated for the simultaneous quantification of six probe metabolites for the in vitro cytochrome P450 activity determination in hepatic microsomes from patients with hepatic impairment. The metabolites acetaminophen (CYP1A2), 4'-hydroxy-mephenytoin (CYP2C19), 4-hydroxy-tolbutamide (CYP2C9), dextrorphan (CYP2D6), 6-hydroxy-chlorzoxazone (CYP2E1) and 1-hydroxy-midazolam (CYP3A4), together with the internal standard chlorpropamide, were separated on a Waters Acquity UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 mu m particle size) with VanGuard pre-column (5 mm x 2.1 mm, 1.7 mu m particle size). A short gradient elution (total run time of 5.25 min), using water with 0.1% formic acid (eluent A) and acetonitrile with 0.1% formic acid (eluent B) at a flow rate of 400 mu l/min, was used. The metabolites were detected with a triple quadrupole mass spectrometer in the multiple reaction monitoring mode. Two runs, one in the positive ionization mode and one in the negative mode, were necessary for the detection of all metabolites. The method was selective and showed good accuracy (84.59-109.83%) and between-day (RSD% < 5.13%) and within-day (RSD% < 9.60%) precision. The LOQ was in full accordance with the intended application, and no relative matrix effects were observed. Also, the sample incubation extracts were stable after three freeze-thaw cycles. The usability of the method was demonstrated by the incubation of pediatric microsomes with subsequent quantification of the formed metabolites and CYP activity calculation. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 24 条
[1]   A rapid ultra-performance liquid chromatography/tandem mass spectrometric methodology for the in vitro analysis of Pooled and Cocktail cytochrome P450 assays [J].
Alden, Peter G. ;
Plumb, Robert S. ;
Jones, Michael D. ;
Rainville, Paul D. ;
Shave, Darcy .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (01) :147-154
[2]  
[Anonymous], 2002, BIOAN METH VAL
[3]  
Burkart J.A., 1986, Appl. Ind. Hyg, V3, P153
[4]  
GEORGE J, 1995, HEPATOLOGY, V21, P120, DOI 10.1016/0270-9139(95)90418-2
[5]   High-throughput screening of inhibitory potential of nine cytochrome P450 enzymes in vitro using liquid chromatography/tandem mass spectrometry [J].
Kim, MJ ;
Kim, H ;
Cha, IJ ;
Park, JS ;
Shon, JH ;
Liu, KH ;
Shin, JG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) :2651-2658
[6]   Strategies to in vitro assessment of major human CYP enzyme activities by using liquid chromatography tandem mass spectrometry [J].
Lahoz, A. ;
Donato, M. T. ;
Castell, J. V. ;
Gomez-Lechon, M. J. .
CURRENT DRUG METABOLISM, 2008, 9 (01) :12-19
[7]   Determination of major human cytochrome P450s activities in 96-well plates using liquid chromatography tandem mass spectrometry [J].
Lahoz, A. ;
Donato, M. T. ;
Picazo, L. ;
Gomez-Lechon, M. J. ;
Castell, J. V. .
TOXICOLOGY IN VITRO, 2007, 21 (07) :1247-1252
[8]   Validated method for rapid inhibition screening of six cytochrome P450 enzymes by liquid chromatography-tandem mass spectrometry [J].
Li, Xiaoyan ;
Chen, Xiaoyan ;
Li, Qiang ;
Wang, Linling ;
Zhong, Dafang .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :128-137
[9]   In vitro assessment of cytochrome P450 inhibition:: Strategies for increasing LC/MS-Based assay throughput using a one-point IC50 method and multiplexing high-performance liquid chromatography [J].
Lin, Tong ;
Pan, Kristine ;
Mordenti, Joyce ;
Pan, Lin .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 96 (09) :2485-2493
[10]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+