Construction of a fluorine substituted chromenylium-cyanine near-infrared fluorophore for ratiometric sensing

被引:25
作者
Zhu, Xiaoyan [1 ,2 ]
Yuan, Lin [1 ]
Hu, Xiaoxiao [3 ]
Zhang, Lili [1 ]
Liang, Yuxin [1 ]
He, Shengyuan [1 ]
Zhang, Xiao-Bing [1 ]
Tan, Weihong [1 ]
机构
[1] Hunan Univ, Collaborat Innovat Ctr Chem & Mol Med, Coll Biol,Mol Sci & Biomed Lab, Coll Chem & Chem Engn,State Key Lab Chemo Biosens, Changsha 410082, Hunan, Peoples R China
[2] Hunan City Univ, Coll Mat & Chem Engn, Yiyang 413000, Peoples R China
[3] Hunan Univ, Aptamer Engn Ctr Hunan Prov, Coll Chem & Chem Engn,Coll Life Sci, Mol Sci & Biomed Lab,State Key Lab Chemo Biosensi, Changsha 410082, Hunan, Peoples R China
关键词
Near-infrared; Ratiometric; Fluorescent probe; Mitochondria-targeted; Cysteine; Imaging; RESPONSIVE FLUORESCENT-PROBES; OFF-ON PROBE; IN-VIVO; LIVING CELLS; SELECTIVE DETECTION; DESIGN STRATEGIES; BIOIMAGING APPLICATIONS; 2-PHOTON PROBES; SUPEROXIDE; CYSTEINE;
D O I
10.1016/j.snb.2017.12.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Near-infrared (NIR) fluorescent probes have been considered as powerful tools for exploring bioactive species and biological processes in living systems by virtue of the substantial merits of the NIR window (such as minimal photo-toxicity, deep tissue penetration, and low background interference). However, the development of effective NIR fluorescent probes for biological application is still facing great challenges due to some weakness (for example, pH sensitivity, poor chemical and photo-stability) of mainly current NIR fluorophores. Herein, we synthesized a novel fluorine atom substituted NIR chromenylium-cyanine fluorophore, termed CCF-OH, with an optically tunable hydroxyl group. Compound CCF-OH possess several optical advantages, including high chemical stability, high photo-stability, and high fluorescence quantum yield (Phi = 0.47). Significantly, a low pK(a) value (6.3) of CCF-OH was obtained, making its fluorescence signal steady around the pH ranging from 6.8 to 8.1. To demonstrate the practicability of CCF-OH, a mitochondria-targeted near-infrared fluorescent probe, N-Cys, was developed by masking the hydroxyl group of CCF-OH with an acrylate group as the recognition unit for cysteine (Cys). N-Cys responded to Cys with an obvious ratiometric signal. Furthermore, N-Cys has also been successfully applied for ratiometric NIR imaging of Cys in living cells, suggesting the great potential of the new NIR fluorophore, CCF-OH, for practical applications in living systems. (c) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 225
页数:7
相关论文
共 48 条
  • [11] Fluorescent Probe HKSOX-1 for Imaging and Detection of Endogenous Superoxide in Live Cells and In Vivo
    Hu, Jun Jacob
    Wong, Nai-Kei
    Ye, Sen
    Chen, Xingmiao
    Lu, Ming-Yang
    Zhao, Angela Qian
    Guo, Yuhan
    Ma, Alvin Chun-Hang
    Leung, Anskar Yu-Hung
    Shen, Jiangang
    Yang, Dan
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2015, 137 (21) : 6837 - 6843
  • [12] Small-Molecule Two-Photon Probes for Bioimaging Applications
    Kim, Hwan Myung
    Cho, Bong Rae
    [J]. CHEMICAL REVIEWS, 2015, 115 (11) : 5014 - 5055
  • [13] Two-Photon Probes for Intracellular Free Metal Ions, Acidic Vesicles, And Lipid Rafts in Live Tissues
    Kim, Hwan Myung
    Cho, Bong Rae
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 2009, 42 (07) : 863 - 872
  • [14] BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
    Kowada, Toshiyuki
    Maeda, Hiroki
    Kikuchi, Kazuya
    [J]. CHEMICAL SOCIETY REVIEWS, 2015, 44 (14) : 4953 - 4972
  • [15] Hydrocyanines: A Class of Fluorescent Sensors That Can Image Reactive Oxygen Species in Cell Culture, Tissue, and In Vivo
    Kundu, Kousik
    Knight, Sarah F.
    Willett, Nick
    Lee, Scingmun
    Taylor, W. Robert
    Murthy, Niren
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (02) : 299 - 303
  • [16] Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
    Lee, Min Hee
    Kim, Jong Seung
    Sessler, Jonathan L.
    [J]. CHEMICAL SOCIETY REVIEWS, 2015, 44 (13) : 4185 - 4191
  • [17] Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
    Li, Xiaohua
    Gao, Xinghui
    Shi, Wen
    Ma, Huimin
    [J]. CHEMICAL REVIEWS, 2014, 114 (01) : 590 - 659
  • [18] Hemicyanine-based High Resolution Ratiometric near-Infrared Fluorescent Probe for Monitoring pH Changes in Vivo
    Li, Yinhui
    Wang, Yijun
    Yang, Sheng
    Zhao, Yirong
    Yuan, Lin
    Zheng, Jing
    Yang, Ronghua
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (04) : 2495 - 2503
  • [19] in vivo imaging and detection of nitroreductase in zebrafish by a new near-infrared fluorescence off-on probe
    Li, Zhao
    He, Xinyuan
    Wang, Zhe
    Yang, Ronghua
    Shi, Wen
    Ma, Huimin
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 63 : 112 - 116
  • [20] AIEgen based light-up probes for live cell imaging
    Liang, Jing
    Feng, Guangxue
    Kwok, Ryan Tsz Kin
    Ding, Dan
    Tang, Benzhong
    Liu, Bin
    [J]. SCIENCE CHINA-CHEMISTRY, 2016, 59 (01) : 53 - 61