Focused microwave-induced combustion for digestion of botanical samples and metals determination by ICP OES and ICP-MS

被引:43
作者
Barin, J. S. [1 ]
Pereira, J. S. F. [1 ]
Mello, P. A. [1 ]
Knorr, C. L. [1 ]
Moraes, D. P. [2 ]
Mesko, M. F. [3 ]
Nobrega, J. A. [4 ]
Korn, M. G. A. [5 ]
Flores, E. M. M. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[3] Univ Fed Pelotas, Inst Quim & Geociencias, BR-96010610 Pelotas, RS, Brazil
[4] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
[5] Univ Fed Bahia, Inst Quim, Dept Quim Analit, BR-40170290 Salvador, BA, Brazil
基金
巴西圣保罗研究基金会;
关键词
Focused microwave; Microwave-induced combustion; Trace plant analysis; Residual carbon content; OPTICAL-EMISSION-SPECTROMETRY; CRUDE-OIL; ELEMENTS; SULFUR; ACID; COAL;
D O I
10.1016/j.talanta.2012.03.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The advantages and shortcomings of focused microwave-induced combustion (FMIC) for digestion of plant samples were studied. The effects of sample mass, absorbing solution, oxygen gas flow-rate, and time of reflux step on recoveries of major, minor and trace metals were systematically evaluated. Afterwards, Al, Ba, Ca, Co, Cr, Cu, Mg, Mn, Ni, Sr, V. and Zn were determined by inductively coupled plasma optical emission spectrometry (ICP OES) and by inductively coupled plasma mass spectrometry (ICP-MS). The main advantages of FMIC when compared to microwave-assisted wet digestion (MAWD) and focused-microwave-assisted wet digestion (FMAWD) are the possibility to digest larger masses of samples (up to 3 g) using shorter heating times and diluted nitric acid solution for absorbing all analytes. Using the selected experimental conditions for FMIC, residual carbon content was lower than 0.7% for all samples and relative standard deviation (RSD) varied from 1.5 to 14.1%. Certified reference materials (NIST 1515 apple leaves and NIST 1547 peach leaves) were used for checking accuracy and determined values for all metals were in agreement with certified values at a 95% confidence level. No statistical difference (ANOVA, 95% of confidence level) was observed for results obtained by FMIC, FMAWD, and MAWD. Limits of detection were lower when using FMIC in the range of 0.02-0.15 mu g g(-1) for ICP OES and 0.001-0.01 mu g g(-1) for ICP-MS, which were about 3 and 6 times lower than the values obtained by FMAWD and MAWD, respectively. It is important to point out that FMIC was a suitable sample preparation method for major, minor and trace metals by both determination techniques (ICP OES and ICP-MS). Additionally, since it allows lower LODs (because up to 3 g of sample can be digested) and diluted acid solutions are used (without any further dilution), the use of ICP-MS is not mandatory. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:308 / 314
页数:7
相关论文
共 21 条
  • [1] Heavy metals in Egyptian spices and medicinal plants and the effect of processing on their levels
    Abou-Arab, AAK
    Abou Donia, MA
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (06) : 2300 - 2304
  • [2] [Anonymous], 2003, PERKINELMER SCIEX EL
  • [3] Determination of toxic elements in coal by ICP-MS after digestion using microwave-induced combustion
    Antes, Fabiane G.
    Duarte, Fabio A.
    Mesko, Marcia F.
    Nunes, Matheus A. G.
    Pereira, Vanda A.
    Mueller, Edson I.
    Dressler, Valderi L.
    Flores, Erico M. M.
    [J]. TALANTA, 2010, 83 (02) : 364 - 369
  • [4] Anton Paar GmbH, 2003, MICR SAMPL PREP SYST
  • [5] Focused-microwave-assisted digestion of encapsulated lubricating oils:: Gradual sample addition to pre-heated acid
    Bressani, Flavia A.
    Silva, Hamilton O.
    Nobrega, Joaquim A.
    Costa, Leticia M.
    Nogueira, Ana Rita A.
    [J]. QUIMICA NOVA, 2006, 29 (06): : 1210 - 1214
  • [6] Focused microwave-assisted acid digestion of oils:: an evaluation of the residual carbon content
    Costa, LM
    Silva, FV
    Gouveia, ST
    Nogueira, ARA
    Nóbrega, JA
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1981 - 1985
  • [7] Determination of halogens in coal after digestion using the microwave-induced combustion technique
    Flores, Erico M. M.
    Mesko, Marcia F.
    Moraes, Diogo P.
    Pereira, Juliana S. F.
    Mello, Paola A.
    Barin, Juliano S.
    Knapp, Guenter
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (06) : 1865 - 1870
  • [8] Sample preparation techniques based on combustion reactions in closed vessels - A brief overview and recent applications
    Flores, Erico M. M.
    Barin, Juliano S.
    Mesko, Marcia F.
    Knapp, Guenter
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 1051 - 1064
  • [9] Comparison of digestion methods for determination of trace minor metals in plant samples
    Lavilla, I
    Filgueiras, AV
    Bendicho, C
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (12) : 5072 - 5077
  • [10] Determination of sulfur in petroleum coke combining closed vessel Microwave-Induced Combustion and Inductively Coupled Plasma-Optical Emission Spectrometry
    Mello, Paola de A.
    Giesbrecht, Cristiano K.
    Alencar, Mauricio S.
    Moreira, Elizabeth M.
    Paniz, Jose N. G.
    Dressler, Valderi L.
    Flores, Erico M. M.
    [J]. ANALYTICAL LETTERS, 2008, 41 (09) : 1623 - 1632