Measuring, modeling, and decoupling of saturation-induced saliencies in carrier-signal injection-based sensorless AC drives

被引:69
作者
Briz, F [1 ]
Degner, MW
Diez, A
Lorenz, RD
机构
[1] Univ Oviedo, Dept Elect Comp & Syst Engn, E-33204 Gijon, Spain
[2] Ford Motor Co, Sci Res Lab, Dearborn, MI 48121 USA
[3] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
关键词
position estimation; self-sensing; sensorless control;
D O I
10.1109/28.952511
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The focus of this paper is the measuring, modeling, and decoupling of saturation-induced saliencies in carrier-signal injection-based sensorless control. First, techniques for the measurement of saturation-induced saliencies are presented. The goal of these measurements is to provide useful information on the position and magnitude of the various saturation-induced saliencies. Using the results from several different experimental measurements, models are developed explaining the source and behavior of the saturation-induced saliencies. The paper concludes by presenting methods for decoupling the effects caused by the parasitic saturation-induced saliencies, eliminating the errors that they cause in rotor position or flux angle estimation.
引用
收藏
页码:1356 / 1364
页数:9
相关论文
共 16 条
[1]  
Aime ML, 1998, IEEE IND APPLIC SOC, P159, DOI 10.1109/IAS.1998.732276
[2]  
Alger Philip L., 1970, Induction Machines, Their Behavior and Uses
[3]   Dynamic operation of carrier-signal-injection-based sensorless direct field-oriented AC drives [J].
Briz, F ;
Diez, A ;
Degner, MW .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (05) :1360-1368
[4]  
Cilia J, 1996, IEEE IND APPLIC SOC, P286, DOI 10.1109/IAS.1996.557031
[5]   A new zero-frequency flux-position detection approach for direct-field-oriented-control drives [J].
Consoli, A ;
Scarcella, G ;
Testa, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (03) :797-804
[6]  
CORLEY M, 1999, IEEE T IND APPL, V35, P784
[7]   Position estimation in induction machines utilizing rotor bar slot harmonics and carrier-frequency signal injection [J].
Degner, MW ;
Lorenz, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (03) :736-742
[8]   Using multiple saliencies for the estimation of flux, position, and velocity in AC machines [J].
Degner, MW ;
Lorenz, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) :1097-1104
[9]  
DEGNER MW, 1998, THESIS U WISCONSIN M
[10]   Sensorless field-orientation control of an induction machine by high-frequency signal injection [J].
Ha, JI ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (01) :45-51