The Impact of Utilizing Different Optical Coherence Tomography Devices for Clinical Purposes and in Multiple Sclerosis Trials

被引:58
作者
Warner, Christina V. [1 ]
Syc, Stephanie B. [1 ]
Stankiewicz, Aleksandra M. [1 ]
Hiremath, Girish [1 ]
Farrell, Sheena K. [1 ]
Crainiceanu, Ciprian M. [2 ]
Conger, Amy [3 ]
Frohman, Teresa C. [3 ]
Bisker, Esther R. [4 ]
Balcer, Laura J. [4 ]
Frohman, Elliot M. [3 ]
Calabresi, Peter A. [1 ]
Saidha, Shiv [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Neurol, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Biostat, Bloomberg Sch Publ Hlth, Baltimore, MD 21205 USA
[3] Univ Texas SW Med Ctr Dallas, Dept Neurol, Dallas, TX 75390 USA
[4] Univ Penn, Sch Med, Dept Neurol, Philadelphia, PA 19104 USA
关键词
NERVE-FIBER LAYER; LESION LOAD MEASUREMENTS; SPECTRAL-DOMAIN; TIME-DOMAIN; THICKNESS MEASUREMENTS; INTERSCANNER VARIATION; BRAIN ATROPHY; AXONAL-INJURY; STRATUS OCT; NEURITIS;
D O I
10.1371/journal.pone.0022947
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Optical coherence tomography (OCT) derived retinal measures, particularly peri-papillary retinal nerve fiber layer (RNFL) thickness, have been proposed as outcome measures in remyelinating and neuroprotective trials in multiple sclerosis (MS). With increasing utilization of multiple centers to improve power, elucidation of the impact of different OCT technologies is crucial to the design and interpretation of such studies. In this study, we assessed relation and agreement between RNFL thickness and total macular volume (in MS and healthy controls) derived from three commonly used OCT devices: Stratus time-domain OCT, and Cirrus HD-OCT and Spectralis, two spectral-domain (SD) OCT devices. OCT was performed on both Cirrus HD-OCT and Stratus in 229 participants and on both Cirrus HD-OCT and Spectralis in a separate cohort of 102 participants. Pearson correlation and Bland-Altman analyses were used to assess correlation and agreement between devices. All OCT retinal measures correlated highly between devices. The mean RNFL thickness was 7.4 mu m lower on Cirrus HD-OCT than Stratus, indicating overall poor agreement for this measurement between these machines. Further, the limits of agreement (LOA) between Cirrus HD-OCT and Stratus were wide (-4.1 to 18.9 mu m), indicating poor agreement at an individual subject level. The mean RNFL thickness was 1.94 mm (LOA: -5.74 to 9.62 mu m) higher on Spectralis compared to Cirrus HD-OCT, indicating excellent agreement for this measurement across this cohort. Although these data indicate that these three devices agree poorly at an individual subject level (evidenced by wide LOA in both study cohorts) precluding their co-utilization in everyday practice, the small difference for mean measurements between Cirrus HD-OCT and Spectralis indicate pooled results from these two SD-devices could be used as outcome measures in clinical trials, provided patients are scanned on the same machine throughout the trial, similar to the utilization of multiple different MRI platforms in MS clinical trials.
引用
收藏
页数:11
相关论文
共 69 条
[1]  
AG Heckenlively JR, PRINCIPLES PRACTICES, P25
[2]   COMPARISON OF METHODS OF MEASURING BLOOD-PRESSURE [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1986, 40 (03) :274-275
[3]   Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT [J].
Arthur, S. N. ;
Smith, S. D. ;
Wright, M. M. ;
Grajewski, A. L. ;
Wang, Q. ;
Terry, J. M. ;
Lee, M. S. .
EYE, 2011, 25 (02) :192-200
[4]   Optic neuritis [J].
Balcer, LJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 354 (12) :1273-1280
[5]   Axonal and neuronal degeneration in multiple sclerosis: mechanisms and functional consequences [J].
Bjartmar, C ;
Trapp, BD .
CURRENT OPINION IN NEUROLOGY, 2001, 14 (03) :271-278
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Time domain and spectral domain optical coherence tomography in multiple sclerosis: a comparative cross-sectional study [J].
Bock, Markus ;
Brandt, Alexander Ulrich ;
Doerr, Jan ;
Pfueller, Caspar F. ;
Ohlraun, Stephanie ;
Zipp, Frauke ;
Paul, Friedemann .
MULTIPLE SCLEROSIS JOURNAL, 2010, 16 (07) :893-896
[8]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[9]  
Burkholder BM, 2009, ARCH NEUROL-CHICAGO, V66, P1366, DOI 10.1001/archneurol.2009.230
[10]   Detection of cortical inflammatory lesions by double inversion recovery magnetic resonance imaging in patients with multiple sclerosis [J].
Calabrese, Massimiliano ;
De Stefano, Nicola ;
Atzori, Matteo ;
Bernardi, Valentina ;
Mattisi, Irene ;
Barachino, Luigi ;
Morra, Aldo ;
Rinaldi, Luciano ;
Romualdi, Chiara ;
Perini, Paola ;
Battistin, Leontino ;
Gallo, Paolo .
ARCHIVES OF NEUROLOGY, 2007, 64 (10) :1416-1422