Comparison of electrode materials for the detection of rapid hydrogen peroxide fluctuations using background-subtracted fast scan cyclic voltammetry

被引:27
作者
Roberts, James G. [1 ]
Hamilton, Keri L. [1 ]
Sombers, Leslie A. [1 ]
机构
[1] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
关键词
CARBON-FIBER MICROELECTRODES; ELECTROCHEMICAL OXIDATION; PLATINUM-ELECTRODES; DOPAMINE RELEASE; IN-VIVO; H2O2; NAFION; BRAIN; ADSORPTION; SYSTEMS;
D O I
10.1039/c1an15337d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen peroxide (H(2)O(2)) is a critically important signaling molecule. Endogenous H(2)O(2) mediates diverse physiological processes both intra-and intercellularly; and enzymatically generated H(2)O(2) is a widely used reporter molecule at biosensors that rely on enzymes to detect non-electroactive species. However, the development and application of electroanalytical methods for the direct detection of this molecule has been challenging because the electron transfer kinetics for the irreversible oxidation of H(2)O(2) are slow. We comparatively characterize the electrochemical oxidation of H(2)O(2) on bare and Nafion (R)-coated platinum and carbon-fiber microdisc electrodes using fast-scan cyclic voltammetry (FSCV). Using a waveform ranging from +0.2 to +1.3 V at 400 V s(-1), the electrocatalytic properties of the platinum surface were not readily apparent, and the carbon-fiber microelectrode demonstrated greater sensitivity and selectivity toward H(2)O(2). Nafion (R)-coating further enhanced detection on carbon electrodes. These results confirm that platinum electrodes, with or without Nafion (R), will not work acceptably with this approach, and confirm the value of carbon-fiber microelectrodes relative to more traditionally used platinum electrodes in the direct detection of rapid H(2)O(2) fluctuations using FSCV.
引用
收藏
页码:3550 / 3556
页数:7
相关论文
共 53 条
  • [1] [Anonymous], 1996, REV EXPANDED
  • [2] [Anonymous], 2001, ELECTROCHEMICAL METH
  • [3] ELECTRODE-KINETICS OF THE OXIDATION OF HYDROGEN-PEROXIDE AT PRETREATED GLASSY-CARBON AND CARBON-FIBER ELECTRODES
    AOKI, K
    ISHIDA, M
    TOKUDA, K
    HASEBE, K
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 251 (01): : 63 - 71
  • [4] AMPA receptor-dependent H2O2 generation in striatal medium spiny neurons but not dopamine axons:: One source of a retrograde signal that can inhibit dopamine release
    Avshalumov, Marat V.
    Patel, Jyoti C.
    Rice, Margaret E.
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 2008, 100 (03) : 1590 - 1601
  • [5] H2O2 signaling in the nigrostriatal dopamine pathway via ATP-sensitive potassium channels:: Issues and answers
    Avshalumov, Marat V.
    Bao, Li
    Patel, Jyoti C.
    Rice, Margaret E.
    [J]. ANTIOXIDANTS & REDOX SIGNALING, 2007, 9 (02) : 219 - 231
  • [6] Avshalumov MV, 2003, J NEUROSCI, V23, P2744
  • [7] Mitochondria Are the Source of Hydrogen Peroxide for Dynamic Brain-Cell Signaling
    Bao, Li
    Avshalumov, Marat V.
    Patel, Jyoti C.
    Lee, Christian R.
    Miller, Evan W.
    Chang, Christopher J.
    Rice, Margaret E.
    [J]. JOURNAL OF NEUROSCIENCE, 2009, 29 (28) : 9002 - 9010
  • [8] Bard A.J., 1973, Encyclopedia of electrochemistry of the elements
  • [9] Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes
    Bath, BD
    Michael, DJ
    Trafton, BJ
    Joseph, JD
    Runnels, PL
    Wightman, RM
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (24) : 5994 - 6002
  • [10] Ceramic-based multisite microelectrode arrays for simultaneous measures of choline and acetylcholine in CNS
    Burmeister, Jason J.
    Pomerleau, Francois
    Huettl, Peter
    Gash, Clelland R.
    Wemer, Catherine E.
    Bruno, John P.
    Gerhardt, Greg A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (09) : 1382 - 1389