Laser speckle contrast imaging identifies ischemic areas on gastric tube reconstructions following esophagectomy

被引:44
作者
Milstein, Dan M. J. [1 ]
Ince, Can [2 ]
Gisbertz, Suzanne S. [3 ]
Boateng, Kofi B. [4 ]
Geerts, Bart F. [4 ]
Hollmann, Markus W. [4 ]
Henegouwen, Mark I. van Berge [3 ]
Veelo, Denise P. [4 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Oral & Maxillofacial Surg, Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Translat Physiol, Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Surg, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Anesthesiol, Amsterdam, Netherlands
关键词
blood perfusion; esophagectomy; gastric tube reconstruction; laser speckle contrast imaging; RANDOMIZED CONTROLLED-TRIAL; TISSUE BLOOD-FLOW; DOPPLER FLOWMETRY; MICROVASCULAR PERFUSION; CANCER; MICROCIRCULATION; ESOPHAGUS; MODEL; OPTIMIZATION; OXYGENATION;
D O I
10.1097/MD.0000000000003875
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Gastric tube reconstruction (GTR) is a high-risk surgical procedure with substantial perioperative morbidity. Compromised arterial blood supply and venous congestion are believed to be the main etiologic factors associated with early and late anastomotic complications. Identifying low blood perfusion areas may provide information on the risks of future anastomotic leakage and could be essential for improving surgical techniques. The aim of this study was to generate a method for gastric microvascular perfusion analysis using laser speckle contrast imaging (LSCI) and to test the hypothesis that LSCI is able to identify ischemic regions on GTRs.Patients requiring elective laparoscopy-assisted GTR participated in this single-center observational investigation. A method for intraoperative evaluation of blood perfusion and postoperative analysis was generated and validated for reproducibility. Laser speckle measurements were performed at 3 different time pointes, baseline (devascularized) stomach (T0), after GTR (T1), and GTR at 20 degrees reverse Trendelenburg (T2).Blood perfusion analysis inter-rater reliability was high, with intraclass correlation coefficients for each time point approximating 1 (P<0.0001). Baseline (T0) and GTR (T1) mean blood perfusion profiles were highest at the base of the stomach and then progressively declined towards significant ischemia at the most cranial point or anastomotic tip (P<0.01). After GTR, a statistically significant improvement in mean blood perfusion was observed in the cranial gastric regions of interest (P<0.05). A generalized significant decrease in mean blood perfusion was observed across all GTR regions of interest during 20 degrees reverse Trendelenburg (P<0.05).It was feasible to implement LSCI intraoperatively to produce blood perfusion assessments on intact and reconstructed whole stomachs. The analytical design presented in this study resulted in good reproducibility of gastric perfusion measurements between different investigators. LSCI provides spatial and temporal information on the location of adequate tissue perfusion and may thus be an important aid in optimizing surgical and anesthesiological procedures for strategically selecting anastomotic site in patients undergoing esophagectomy with GTR.
引用
收藏
页数:8
相关论文
共 32 条
  • [1] The effect of thoracic epidural bupivacaine and an intravenous adrenaline infusion on gastric tube blood flow during esophagectomy
    Al-Rawi, Omar Y.
    Pennefather, Stephen H.
    Page, Richard D.
    Dave, Ishani
    Russell, Glen N.
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (03) : 884 - 887
  • [2] Real-time assessment of renal cortical microvascular perfusion heterogeneities using near-infrared laser speckle imaging
    Bezemer, Rick
    Legrand, Matthieu
    Klijn, Eva
    Heger, Michal
    Post, Ivo C. J. H.
    van Gulik, Thomas M.
    Payen, Didier
    Ince, Can
    [J]. OPTICS EXPRESS, 2010, 18 (14): : 15054 - 15061
  • [3] Minimally invasive versus open oesophagectomy for patients with oesophageal cancer: a multicentre, open-label, randomised controlled trial
    Biere, Surya S. A. Y.
    Henegouwen, Mark I. van Berge
    Maas, Kirsten W.
    Bonavina, Luigi
    Rosman, Camiel
    Roig Garcia, Josep
    Gisbertz, Suzanne S.
    Klinkenbijl, Jean H. G.
    Hollmann, Markus W.
    de lange, Elly S. M.
    Bonjer, H. Jaap
    van der Peet, Donald L.
    Cuesta, Miguel A.
    [J]. LANCET, 2012, 379 (9829) : 1887 - 1892
  • [4] Quantitative measurement of gastric mucosal microcirculation using a combined laser Doppler flowmeter and spectrophotometer
    Bludau, M.
    Vallboehmer, D.
    Gutschow, C.
    Hoelscher, A. H.
    Schroeder, W.
    [J]. DISEASES OF THE ESOPHAGUS, 2008, 21 (07) : 668 - 672
  • [5] Boyle NH, 1998, BRIT J SURG, V85, P1407
  • [6] Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
    Briers, JD
    [J]. PHYSIOLOGICAL MEASUREMENT, 2001, 22 (04) : R35 - R66
  • [7] The effect of nitroglycerin on microvascular perfusion and oxygenation during gastric tube reconstruction
    Buise, MP
    Ince, C
    Tilanus, HW
    Klein, J
    Gommers, D
    van Bommel, J
    [J]. ANESTHESIA AND ANALGESIA, 2005, 100 (04) : 1107 - 1111
  • [8] Efficient characterization of regional mesenteric blood flow by use of laser speckle imaging
    Cheng, HY
    Luo, QM
    Wang, Z
    Gong, H
    Chen, SB
    Liang, WX
    Zeng, SQ
    [J]. APPLIED OPTICS, 2003, 42 (28) : 5759 - 5764
  • [9] Non-invasive imaging of microcirculation: a technology review
    Eriksson, Sam
    Nilsson, Jan
    Sturesson, Christian
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2014, 7 : 445 - 452
  • [10] FLOW VISUALIZATION BY MEANS OF SINGLE-EXPOSURE SPECKLE PHOTOGRAPHY
    FERCHER, AF
    BRIERS, JD
    [J]. OPTICS COMMUNICATIONS, 1981, 37 (05) : 326 - 330