A Digital Microfluidics Platform for Loop-Mediated Isothermal Amplification Detection

被引:34
作者
Coelho, Beatriz Jorge [1 ,2 ]
Veigas, Bruno [1 ,2 ]
Aguas, Hugo [1 ]
Fortunato, Elvira [1 ]
Martins, Rodrigo [1 ]
Baptista, Pedro Viana [2 ]
Igreja, Rui [1 ]
机构
[1] Univ Nova Lisboa, Dept Ciencia Mat, CENIMAT i3N, Fac Ciencias & Tecnol, Campus Caparica, P-2829516 Caparica, Portugal
[2] Univ Nova Lisboa, Dept Ciencias Vida, UCIBIO, Fac Ciencias & Tecnol, Campus Caparica, P-2829516 Caparica, Portugal
关键词
digital microfluidics; loop-mediated isothermal amplification; c-Myc; lab-on-a-chip; point-of-care diagnostics; POLYMERASE-CHAIN-REACTION; CARE; INTEGRATION; DEVICES; POINT; CHIP; RNA;
D O I
10.3390/s17112616
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Digital microfluidics (DMF) arises as the next step in the fast-evolving field of operation platforms for molecular diagnostics. Moreover, isothermal schemes, such as loop-mediated isothermal amplification (LAMP), allow for further simplification of amplification protocols. Integrating DMF with LAMP will be at the core of a new generation of detection devices for effective molecular diagnostics at point-of-care (POC), providing simple, fast, and automated nucleic acid amplification with exceptional integration capabilities. Here, we demonstrate for the first time the role of coupling DMF and LAMP, in a dedicated device that allows straightforward mixing of LAMP reagents and target DNA, as well as optimum temperature control (reaction droplets undergo a temperature variation of just 0.3 degrees C, for 65 degrees C at the bottom plate). This device is produced using low-temperature and low-cost production processes, adaptable to disposable and flexible substrates. DMF-LAMP is performed with enhanced sensitivity without compromising reaction efficacy or losing reliability and efficiency, by LAMP-amplifying 0.5 ng/mu L of target DNA in just 45 min. Moreover, on-chip LAMP was performed in 1.5 mu L, a considerably lower volume than standard bench-top reactions.
引用
收藏
页数:11
相关论文
共 30 条
[1]   A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips [J].
Ahmad, Farhan ;
Seyrig, Gregoire ;
Tourlousse, Dieter M. ;
Stedtfeld, Robert D. ;
Tiedje, James M. ;
Hashsham, Syed A. .
BIOMEDICAL MICRODEVICES, 2011, 13 (05) :929-937
[2]  
[Anonymous], 2016, USE LOOP MEDIATED IS
[3]  
[Anonymous], CANC GENE PATHWAYS C
[4]  
[Anonymous], BIOSENSORS
[5]   Some examples of micro-devices for biotechnology developed at the Department of Technologies for Life Sciences and Healthcare of the LETI [J].
Berthier, J. ;
Mourier, V. ;
Sarrut, N. ;
Jary, D. ;
Fouillet, Y. ;
Pouteau, P. ;
Caillat, P. ;
Peponnet, C. .
INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2010, 7 (4-8) :802-818
[6]   Prognostic Relevance of c-Myc and BMI1 Expression in Patients With Glioblastoma [J].
Cenci, Tonia ;
Martini, Maurizio ;
Montano, Nicola ;
D'Alessandris, Quintino G. ;
Falchetti, Maria Laura ;
Annibali, Daniela ;
Savino, Mauro ;
Bianchi, Federico ;
Pierconti, Francesco ;
Nasi, Sergio ;
Pallini, Roberto ;
Larocca, Luigi Maria .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 (03) :390-396
[7]   Nucleic acid amplification using microfluidic systems [J].
Chang, Chen-Min ;
Chang, Wen-Hsin ;
Wang, Chih-Hung ;
Wang, Jung-Hao ;
Mai, John D. ;
Lee, Gwo-Bin .
LAB ON A CHIP, 2013, 13 (07) :1225-1242
[8]   Integrated polymerase chain reaction chips utilizing digital microfluidics [J].
Chang, Yi-Hsien ;
Lee, Gwo-Bin ;
Huang, Fu-Chun ;
Chen, Yi-Yu ;
Lin, Jr-Lung .
BIOMEDICAL MICRODEVICES, 2006, 8 (03) :215-225
[9]   Digital Microfluidics [J].
Choi, Kihwan ;
Ng, Alphonsus H. C. ;
Fobel, Ryan ;
Wheeler, Aaron R. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 5, 2012, 5 :413-440
[10]   Digital Microfluidics for Nucleic Acid Amplification [J].
Coelho, Beatriz ;
Veigas, Bruno ;
Fortunato, Elvira ;
Martins, Rodrigo ;
Aguas, Hugo ;
Igreja, Rui ;
Baptista, Pedro V. .
SENSORS, 2017, 17 (07)