Cavity-shaped magnet for highly sensitive magnetic detection of magnetic nanoparticles in breast cancer patients

被引:0
作者
Kuwahata, Akihiro [1 ]
Kusakabe, Moriaki [2 ,3 ]
Chikaki, Shinichi [1 ]
Saito, Itsuro [4 ]
Sekino, Masaki [1 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Tokyo 1138656, Japan
[2] Univ Tokyo, Grad Sch Agr & Life Sci, Tokyo 1138657, Japan
[3] Matrix Cell Res Inst Inc, Ibaraki 3001232, Japan
[4] iMed Japan Inc, Chiba 2750001, Japan
关键词
SENTINEL LYMPH-NODE;
D O I
10.1063/1.5130434
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Magnetic nanoparticles and their detection systems are widely applied to the diverse biomedical applications, and the more accurate detection techniques have been explored. Here, we propose the cavity-shaped magnet that enables the application of the highly sensitive magnetic sensor for the enhancement of the detection ability. The numerical simulations based on the finite element method revealed the wide area of the magnetic null point (B similar to 0 and del B similar to 0) of the cavity-shaped magnet. The strong gradient of magnetic fields of del B-Z similar to 160 mT/mm in the conventional column-shaped magnet reduces to approximately zero and the wider magnetic null area is obtained in the cavity-shaped magnet. The magnetic null area of the column- and cavity-shaped magnet are similar to 0.1 x 0.05 mm(2) and similar to 0.25 x 0.6 mm(2), respectively, indicating that the area expands to approximately 30 times larger. This scale-up of the magnetic null area in the proposed cavity-shaped magnet suggests the application of the highly sensitive magnetic sensor, thereby would be offering the more accurate magnetic nanoparticle detection for biomedical applications.
引用
收藏
页数:5
相关论文
共 14 条
[1]  
[Anonymous], J SURG ONCOL UNPUB
[2]  
Bray F, 2018, CA Cancer J Clin, V68, P424, DOI [10.3322/caac.21492, DOI 10.3322/caac.20115]
[3]   Sentinel Node Biopsy Using a Magnetic Tracer Versus Standard Technique: The SentiMAG Multicentre Trial [J].
Douek, Michael ;
Klaase, Joost ;
Monypenny, Ian ;
Kothari, Ashutosh ;
Zechmeister, Katalin ;
Brown, Douglas ;
Wyld, Lynda ;
Drew, Philip ;
Garmo, Hans ;
Agbaje, Olorunsola ;
Pankhurst, Quentin ;
Anninga, Bauke ;
Grootendorst, Maarten ;
ten Haken, Bennie ;
Hall-Craggs, Margaret A. ;
Purushotham, Arnie ;
Pinder, Sarah .
ANNALS OF SURGICAL ONCOLOGY, 2014, 21 (04) :1237-1245
[4]   LYMPHATIC MAPPING AND SENTINEL LYMPHADENECTOMY FOR BREAST-CANCER [J].
GIULIANO, AE ;
KIRGAN, DM ;
GUENTHER, JM ;
MORTON, DL .
ANNALS OF SURGERY, 1994, 220 (03) :391-401
[5]   Single defect centres in diamond: A review [J].
Jelezko, F. ;
Wrachtrup, J. .
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2006, 203 (13) :3207-3225
[6]   Superparamagnetic nanoparticle detection system by using a fundamental mode orthogonal fluxgate (FM-OFG) gradiometer [J].
Karo, Hikaru ;
Sasada, Ichiro .
AIP ADVANCES, 2017, 7 (05)
[7]   Sentinel Node Mapping for Gastric Cancer: A Prospective Multicenter Trial in Japan [J].
Kitagawa, Yuko ;
Takeuchi, Hiroya ;
Takagi, Yu ;
Natsugoe, Shoji ;
Terashima, Masanori ;
Murakami, Nozomu ;
Fujimura, Takashi ;
Tsujimoto, Hironori ;
Hayashi, Hideki ;
Yoshimizu, Nobunari ;
Takagane, Akinori ;
Mohri, Yasuhiko ;
Nabeshima, Kazuhito ;
Uenosono, Yoshikazu ;
Kinami, Shinichi ;
Sakamoto, Junichi ;
Morita, Satoshi ;
Aikou, Takashi ;
Miwa, Koichi ;
Kitajima, Masaki .
JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (29) :3704-+
[8]   SURGICAL RESECTION AND RADIOLOCALIZATION OF THE SENTINEL LYMPH-NODE IN BREAST-CANCER USING A GAMMA-PROBE [J].
KRAG, DN ;
WEAVER, DL ;
ALEX, JC ;
FAIRBANK, JT .
SURGICAL ONCOLOGY-OXFORD, 1993, 2 (06) :335-340
[9]   Three-dimensional sensitivity mapping of a handheld magnetic probe for sentinel lymph node biopsy [J].
Kuwahata, Akihiro ;
Chikaki, Shinichi ;
Ergin, Asli ;
Kaneko, Miki ;
Kusakabe, Moriaki ;
Sekino, Masaki .
AIP ADVANCES, 2017, 7 (05)
[10]  
Ookubo T, 2013, IEEE ENG MED BIO, P5485, DOI 10.1109/EMBC.2013.6610791