ELECTROHYDRODYNAMIC MINI FLAT HEAT PIPE FOR ADVANCED ELECTRONICS COOLING

被引:0
作者
Xin, Fei [1 ,2 ]
Ma, Ting [1 ]
Yan, Yuying [2 ]
Wang, Qiuwang [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Thermofluid Sci & Engn, MOE, Xian 710049, Shaanxi, Peoples R China
[2] Univ Nottingham, Fac Engn, Nottingham NG7 2RD, England
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
flat heat pipe; mathematical model; electrohydrodynamics; dielectrophoretic force; heat transfer performance; THERMAL PERFORMANCE; 2-PHASE FLOW; ENHANCEMENT; TRANSPORT; LIQUID; GROOVES; FIELD;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Mini-grooved flat heat pipe with small size, compact structure, high thermal conductivity, and close contact with chips is very promising to be applied for electronic devices cooling under small space and high heat flux condition. However, capillary limit always restricts the heat transfer capacity of heat pipe. Adopting electrohydrodynamic (EHD) technology with simple structure, sensitive control, and low-energy consumption to the heat pipe can lower the reliance of heat pipe on capillary force and improve the heat transfer performance of heat pipe. In this paper, a one-dimensional mathematical model is established for mini-grooved flat heat pipe under dielectrophoretic force to study the working fluid flow and heat transfer along axial direction under EHD effect. The performance of mini-grooved flat heat pipe under different electric field intensity and electrodes distribution is analyzed. It is found that adding electric field to the mini-grooved flat heat pipe can lessen the demand for capillary force on the heat pipe, reduce the required working fluid filling amount, improve the wall temperature uniformity, and enlarge the range of negative working inclined angle, which enhances the heat transfer performance of heat pipe significantly. Under the electric field intensity 5 kV. mm(-1), the critical input heat of Case 1 heat pipe is 4.8 times higher than that without electric field. And, when electrodes are arranged at the whole heat pipe with Case 2 convey gradient V-type grooved wick, the heat transfer performance of heat pipe is optimal. Considering the practical condition, fabricating sloped grooved heat pipe under EHD is more convenient. However, the electric field intensity cannot be larger than 5.5 kV.mm(-1) in case of reaching entrainment limit and electrical properties of working fluid being destroyed.
引用
收藏
页码:43 / 59
页数:17
相关论文
共 30 条
  • [1] ELECTROHYDRODYNAMIC ENHANCEMENT OF HEAT-TRANSFER AND FLUID-FLOW
    ALLEN, PHG
    KARAYIANNIS, TG
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (05): : 389 - 423
  • [2] [Anonymous], ASME INT MECH ENG C
  • [3] Heat transport enhancement of monogroove heat pipe with electrohydrodynamic pumping
    Bryan, JE
    SeyedYagoobi, J
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1997, 11 (03) : 454 - 460
  • [4] Enhancement of condensation heat transfer by means of EHD condensate drainage
    Butrymowicz, D
    Trela, M
    Karwacki, J
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (07) : 646 - 657
  • [5] Chen C., 2009, 2009 IEEE C EL INS D
  • [6] Chubb L.W., 1916, UK Patent, Patent No. [100796, 100796 100796]
  • [7] A two-phase flow pattern map for annular channels under a DC applied voltage and the application to electrohydrodynamic convective boiling analysis
    Cotton, J
    Robinson, AJ
    Shoukri, M
    Chang, JS
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (25-26) : 5563 - 5579
  • [8] An electrohydrodynamic polarization micropump for electronic cooling
    Darabi, J
    Ohadi, MM
    DeVoe, D
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2001, 10 (01) : 98 - 106
  • [9] Effect of electric field on the enhanced heat transfer characteristic of an evaporator with multilayered sintered copper mesh
    Diao, Y. H.
    Liu, Y.
    Zhang, J.
    Guo, L.
    Zhao, Y. H.
    Wang, S.
    [J]. JOURNAL OF ELECTROSTATICS, 2015, 73 : 26 - 32
  • [10] Gumerov N.A., 1999, CHEM COMMUN, V46, P3797